Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 222

The DOI matches its Crossref record.

Immune Response to Synthetic Materials: Sensitization of Patients Receiving Orthopaedic Implants

Merritt, Katharine, Rodrigo, Juan J.·1996·Clinical Orthopaedics and Related Research

Abstract

Metallic orthopaedic devices are composed of elements that are known to be skin sensitizers in the general population. There is concern about the possibility of sensitivity reactions in patients bearing these implants. Blood samples were drawn from 22 patients having primary total joint replacement and who had no known prior metal allergies or exposure. Repeat blood samples were drawn 3 months to 1 year later. All preoperative blood samples showed no immune reactions against titanium, cobalt, chromium, or nickel ion solutions in a leukocyte migration inhibition test. Thirty two percent (7 of 22) of the patients developed sensitivity to at least 1 of the antigens, but only 5 percent (1 of 22) developed a severe reaction. Review of the literature and these studies has indicated that such reactions can occur. However, the incidence seems to be very low.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003086-199605000-00009

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 222

Metadata

Authors
Merritt, K., & Rodrigo, J. J.
Venue
Clinical Orthopaedics and Related Research
Published
1996-05
Volume
326
Issue
326
Pages
71-79
ISSN
0009-921X (ISSN-L)
OpenAlex
W2054595138
Cited by
222
References
0
FWCI
1.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Immune Response to Synthetic Materials: Sensitization of Patients Receiving Orthopaedic Implants. https://app.cochat.ai/papers/10.1097/00003086-199605000-00009
The paper
Merritt, K., & Rodrigo, J. J. (1996). Immune Response to Synthetic Materials: Sensitization of Patients Receiving Orthopaedic Implants. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-199605000-00009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.