Immune Response to Synthetic Materials: Sensitization of Patients Receiving Orthopaedic Implants
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Metallic orthopaedic devices are composed of elements that are known to be skin sensitizers in the general population. There is concern about the possibility of sensitivity reactions in patients bearing these implants. Blood samples were drawn from 22 patients having primary total joint replacement and who had no known prior metal allergies or exposure. Repeat blood samples were drawn 3 months to 1 year later. All preoperative blood samples showed no immune reactions against titanium, cobalt, chromium, or nickel ion solutions in a leukocyte migration inhibition test. Thirty two percent (7 of 22) of the patients developed sensitivity to at least 1 of the antigens, but only 5 percent (1 of 22) developed a severe reaction. Review of the literature and these studies has indicated that such reactions can occur. However, the incidence seems to be very low.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reactions of the articular capsule to wear products of artificial joint prostheses
Willert, H. ‐., & Semlitsch, M. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110202 · Cited by 822
Sensitivity to titanium. A cause of implant failure?
Lalor, P., Revell, P., Gray, A., Wright, S., Railton, G., & Freeman, M. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b1.1991768 · Cited by 393
The Ionization of Metal Implants in Living Tissues
Ferguson, A. B., Laing, P. G., & Hodge, E. S. (1960) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196042010-00007 · Cited by 258
Nickel, cobalt and chromium in consumer products: a role in allergic contact dermatitis?
Basketter, D. A., Briatico‐Vangosa, G., Kaestner, W., Lally, C., & Bontinck, W. J. (1993) · Contact Dermatitis · doi:10.1111/j.1600-0536.1993.tb03318.x · Cited by 257
The skin immune system Its cellular constituents and their interactions
Bos, J. D., & Kapsenberg, M. L. (1986) · Immunology Today · doi:10.1016/0167-5699(86)90111-8 · Cited by 233
Composition and in vitro corrosion of orthodontic appliances
Grimsdottir, M. R., Gjerdet, N. R., & Hensten-Pettersen, A. (1992) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/0889-5406(92)70127-v · Cited by 180
Systemic effects of biomaterials
Blac, J. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90061-9 · Cited by 166
Kanerva, L., Estiander, T., Jolanki, R., & Tarvainijn, K. (1993) · Contact Dermatitis · doi:10.1111/j.1600-0536.1993.tb03430.x · Cited by 127
Detection of antibodies against corrosion products in patients after CoCr total joint replacements
Yang, J. M., & Merritt, K. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820281102 · Cited by 93
Self-citationPrevalence of contact allergy by sex, race and age
Goh, C. L. (1986) · Contact Dermatitis · doi:10.1111/j.1600-0536.1986.tb01232.x · Cited by 89
Cited by
A Review on Biomedical Titanium Alloys: Recent Progress and Prospect
Zhang, L., & Chen, L. (2019) · Advanced Engineering Materials · doi:10.1002/adem.201801215 · Cited by 1,100
Metal Sensitivity in Patients with Orthopaedic Implants
Hallab, N., Merritt, K., & Jacobs, J. J. (2001) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200103000-00017 · Cited by 935
Self-citationBiomedical Applications of Titanium Alloys: A Comprehensive Review
Marin, E., & Lanzutti, A. (2023) · Materials · doi:10.3390/ma17010114 · Cited by 489
Metal Allergy—A Review on Exposures, Penetration, Genetics, Prevalence, and Clinical Implications
Thyssen, J. P., & Menné, T. (2010) · Chemical Research in Toxicology · doi:10.1021/tx9002726 · Cited by 398
Wear particles, periprosthetic osteolysis and the immune system
Goodman, S. B. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.06.035 · Cited by 340
“One patient developed a severe reaction [20].”
EARLY OSTEOLYSIS FOLLOWING SECOND-GENERATION METAL-ON-METAL HIP REPLACEMENT
PARK, Y.-S., MOON, Y.-W., LIM, S.-J., YANG, J.-M., AHN, G., & CHOI, Y.-L. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200507000-00014 · Cited by 322
Lymphocyte responses in patients with total hip arthroplasty
Hallab, N. J., Anderson, S., Stafford, T., Glant, T., & Jacobs, J. J. (2005) · Journal of Orthopaedic Research · doi:10.1016/j.orthres.2004.09.001 · Cited by 253
Cui, Y.-W., Wang, L., & Zhang, L.-C. (2024) · Progress in Materials Science · doi:10.1016/j.pmatsci.2024.101277 · Cited by 252
Inorganic Biomaterials for Regenerative Medicine
Brokesh, A. M., & Gaharwar, A. K. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b17801 · Cited by 231
Titanium as a Reconstruction and Implant Material in Dentistry: Advantages and Pitfalls
Özcan, M., & Hämmerle, C. (2012) · Materials · doi:10.3390/ma5091528 · Cited by 229
“Degradation products of metallic biomaterials including titanium may mediate metal hypersensitivity or allergic reactions [93].”
BackgroundBone and metal: An orthopaedic perspective on osseointegration of metals
Goriainov, V., Cook, R., M. Latham, J., G. Dunlop, D., & Oreffo, R. O. C. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.06.004 · Cited by 223
Titanium: a review on exposure, release, penetration, allergy, epidemiology, and clinical reactivity
Fage, S. W., Muris, J., Jakobsen, S. S., & Thyssen, J. P. (2016) · Contact Dermatitis · doi:10.1111/cod.12565 · Cited by 222
Titanium allergy: could it affect dental implant integration?
Siddiqi, A., Payne, A. G. T., De Silva, R. K., & Duncan, W. J. (2011) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2010.02081.x · Cited by 222
“Degradation products of metallic biomaterials including titanium may mediate metal hypersensitivity or allergic reactions (Merritt 1996; Merritt & Rodrigo 1996; Büdinger & Hertl 2000; Hallab et al. 2000; Sicilia et al. 2008; Thomas et al. 2009).”
BackgroundCutaneous and Systemic Hypersensitivity Reactions to Metallic Implants
Basko-Plluska, J. L., Thyssen, J. P., & Schalock, P. C. (2011) · Dermatitis · doi:10.2310/6620.2011.10055 · Cited by 209
“Merritt and Rodrigo, 1996 115 22 , 1% develop cutaneous reactions versus 20–25% of patients who develop implant-induced metal sensitivity without any allergic skin manifestations Hallab et al, 2001 9 N/A Metals corrode in biologic systems, allowing for hapten formation.”
BackgroundSpinal Implant Debris-Induced Osteolysis
Hallab, N. J., Cunningham, B. W., & Jacobs, J. J. (2003) · Spine · doi:10.1097/00007632-200310151-00006 · Cited by 201
“All metals in contact with biologic systems corrode(82,83) and the released ions, while not sensitizers on their own, can activate the immune system by forming complexes with native proteins.(76,84,85) These metalprotein complexes are considered to be candidate antigens (or more loosely termed, allergens) for elicitin…”
BackgroundCadosch, D., Chan, E., Gautschi, O. P., & Filgueira, L. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32625 · Cited by 180
Metadata
- Authors
- Merritt, K., & Rodrigo, J. J.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1996-05
- Volume
- 326
- Issue
- 326
- Pages
- 71-79
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2054595138
- Cited by
- 222
- References
- 16
- FWCI
- 1.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.