The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Metal Sensitivity in Patients with Orthopaedic Implants
Abstract
All metals in contact with biological systems undergo corrosion. This electrochemical process leads to the formation of metal ions, which may activate the immune system by forming complexes with endogenous proteins. Implant degradation products have been shown to be associated with dermatitis, urticaria, and vasculitis. If cutaneous signs of an allergic response appear after implantation of a metal device, metal sensitivity should be considered. Currently, there is no generally accepted test for the clinical determination of metal hypersensitivity to implanted devices. The prevalence of dermal sensitivity in patients with a joint replacement device, particularly those with a failed implant, is substantially higher than that in the general population. Until the roles of delayed hypersensitivity and humoral immune responses to metallic orthopaedic implants are more clearly defined, the risk to patients may be considered minimal. It is currently unclear whether metal sensitivity is a contributing factor to implant failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE CHEMOTACTIC EFFECT OF MIXTURES OF ANTIBODY AND ANTIGEN ON POLYMORPHONUCLEAR LEUCOCYTES
Boyden, S. (1962) · The Journal of Experimental Medicine · doi:10.1084/jem.115.3.453 · Cited by 2,733
Nelson, R. D., Quie, P. G., & Simmons, R. L. (1975) · The Journal of Immunology · doi:10.4049/jimmunol.115.6.1650 · Cited by 1,170
Sensitivity to titanium. A cause of implant failure?
Lalor, P., Revell, P., Gray, A., Wright, S., Railton, G., & Freeman, M. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b1.1991768 · Cited by 393
Nickel, cobalt and chromium in consumer products: a role in allergic contact dermatitis?
Basketter, D. A., Briatico‐Vangosa, G., Kaestner, W., Lally, C., & Bontinck, W. J. (1993) · Contact Dermatitis · doi:10.1111/j.1600-0536.1993.tb03318.x · Cited by 257
Immune Response to Synthetic Materials: Sensitization of Patients Receiving Orthopaedic Implants
Merritt, K., & Rodrigo, J. J. (1996) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199605000-00009 · Cited by 222
Self-citationThe incidence of cancer following total hip replacement
Gillespie, W., Frampton, C., Henderson, R., & Ryan, P. (1988) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.70b4.3403594 · Cited by 222
Cell culture methods for testing Biocompatibility
Pizzoferrato, A., Ciapetti, G., Stea, S., Cenni, E., Arciola, C. R., Granchi, D., & Lucia (1994) · Clinical Materials · doi:10.1016/0267-6605(94)90081-7 · Cited by 207
Black, J., Sherk, H., Bonini, J., Rostoker, W. R., Schajowicz, F., & Galante, J. O. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072010-00021 · Cited by 187
Moulon, C., Vollmer, J., & Weltzien, H. (1995) · European Journal of Immunology · doi:10.1002/eji.1830251216 · Cited by 168
Systemic effects of biomaterials
Blac, J. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90061-9 · Cited by 166
Cited by
Nanomaterials and nanoparticles: Sources and toxicity
Buzea, C., Pacheco, I. I., & Robbie, K. (2007) · Biointerphases · doi:10.1116/1.2815690 · Cited by 3,789
Wang, X., Xu, S., Zhou, S., Xu, W., Leary, M., Choong, P., Qian, M., Brandt, M., & Xie, Y. M. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.012 · Cited by 2,121
Macrophages, Foreign Body Giant Cells and Their Response to Implantable Biomaterials
Sheikh, Z., Brooks, P., Barzilay, O., Fine, N., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095269 · Cited by 701
Osteoinduction of bone grafting materials for bone repair and regeneration
García-Gareta, E., Coathup, M. J., & Blunn, G. W. (2015) · Bone · doi:10.1016/j.bone.2015.07.007 · Cited by 649
Titanium dioxide in our everyday life; is it safe?
Skocaj, M., Filipic, M., Petkovic, J., & Novak, S. (2011) · Radiology and Oncology · doi:10.2478/v10019-011-0037-0 · Cited by 549
Metadata
- Authors
- Hallab, N., Merritt, K., & Jacobs, J. J.
- Venue
- The Journal of Bone and Joint Surgery-American Volume
- Published
- 2001-03
- Volume
- 83
- Issue
- 3
- Pages
- 428-436
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2103907018
- Cited by
- 935
- References
- 30
- FWCI
- 15.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Metal Sensitivity in Patients with Orthopaedic Implants. https://app.cochat.ai/papers/10.2106/00004623-200103000-00017
- The paper
- Hallab, N., Merritt, K., & Jacobs, J. J. (2001). Metal Sensitivity in Patients with Orthopaedic Implants. The Journal of Bone and Joint Surgery-American Volume. https://doi.org/10.2106/00004623-200103000-00017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.