The DOI matches its Crossref record.
In Vivo Kinematic Analysis of a Mobile Bearing Total Knee Prosthesis
Abstract
Ten normal subjects and 10 patients with a posterior cruciate retaining mobile bearing total knee replacement performed successive deep knee bends under fluoroscopy to determine tibiofemoral contact positions. At full extension the average initial contact position for the normal and mobile total knee replacement was 6.2 mm (range, 4.8 to 12 mm) anterior, and -4.4 mm (range, 3.9 to 11 mm) posterior to the sagittal tibial midplane, respectively. At 60 degrees flexion, the normal knee rolled back to -5.8 mm (range, -2.5 to -13.2 mm), whereas the mobile bearing total knee replacement rolled back to -9.2 mm (range, -4 to -17 mm). From 60 degrees to 90 degrees, normal knees rolled back to -7.8 mm (range, -5.8 to -13.8 mm), but the mobile bearing total knee replacement slid anteriorly to -5 mm (range, 2 to -12 mm). All mobile bearing total knee replacements had some form of roll back, but some slid anterior more than others. Five of 10 mobile bearing total knee replacements had some movement of the bearings while the others remained fixed. Patellar kinematics was similar to normal but reflected tibiofemoral abnormalities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
In Vivo Fluoroscopic Analysis of the Normal Human Knee
Komistek, R. D., Dennis, D. A., & Mahfouz, M. (2003) · Clinical Orthopaedics & Related Research · doi:10.1097/01.blo.0000062384.79828.3b · Cited by 436
Self-citationIn vivo determination of normal and anterior cruciate ligament-deficient knee kinematics
Dennis, D. A., Mahfouz, M. R., Komistek, R. D., & Hoff, W. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.042 · Cited by 302
Self-citationAnalysis of Forearm Rotational Motion Using Biplane Fluoroscopic Intensity-Based 2D-3D Matching
Abe, S., Otake, Y., Tennma, Y., Hiasa, Y., Oka, K., Tanaka, H., Shigi, A., Miyamura, S., Sato, Y., & Murase, T. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.04.017 · Cited by 8
Metadata
- Authors
- Stiehl, J. B., Dennis, D. A., Komistek, R. D., & Keblish, P. A.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1997-12
- Volume
- 345
- Issue
- 345
- Pages
- 60???66
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2000175909
- Cited by
- 185
- References
- 0
- FWCI
- 4.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In Vivo Kinematic Analysis of a Mobile Bearing Total Knee Prosthesis. https://app.cochat.ai/papers/10.1097/00003086-199712000-00010
- The paper
- Stiehl, J. B., Dennis, D. A., Komistek, R. D., & Keblish, P. A. (1997). In Vivo Kinematic Analysis of a Mobile Bearing Total Knee Prosthesis. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-199712000-00010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.