The DOI matches its Crossref record.
Norian SRS Cement Augmentation in Hip Fracture Treatment: Laboratory and Initial Clinical Results
Abstract
Bone quality, initial fracture displacement, severity of fracture comminution, accuracy of fracture reduction, and the placement of the internal fixation device are important factors that affect fixation stability. New high strength cements that are susceptible to remodeling and replacement for fracture fixation may lead to improved clinical outcome in the treatment of hip fractures. Norian SRS is an injectable, fast setting cement that cures in vivo to form an osteoconductive carbonated apatite of high compressive strength (55 MPa) with chemical and physical characteristics similar to the mineral phase of bone. It can be used as a space filling internal fixation device to facilitate the geometric reconstruction, load transfer, and healing of bone with defects and/or fractures in regions of cancellous bone. Furthermore, this cement can improve the mechanical holding strength of conventional fixation devices. Use of this material potentially could improve fracture stability, retain anatomy during fracture healing and improve hip function, thus achieving better clinical outcomes. In vivo animal studies have shown the material's biocompatibility, and cadaveric studies have shown the biomechanical advantage of its use in hip fractures. Initial clinical experience (in 52 femoral neck fractures and 39 intertrochanteric fractures) showed the potential clinical use of this innovative cement in the treatment of hip fractures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
BONE-GRAFTING AND BONE-GRAFT SUBSTITUTES
FINKEMEIER, C. G. (2002) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200203000-00020 · Cited by 1,099
Calcium orthophosphates in medicine: from ceramics to calcium phosphate cements
Bohner, M. (2000) · Injury · doi:10.1016/s0020-1383(00)80022-4 · Cited by 982
Synthetic bone graft substitutes
Moore, W. R., Graves, S. E., & Bain, G. I. (2001) · ANZ Journal of Surgery · doi:10.1046/j.1440-1622.2001.02128.x · Cited by 826
Laurencin, C., Khan, Y., & El-Amin, S. F. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.3.1.49 · Cited by 716
Bone Grafts and Bone Graft Substitutes in Orthopaedic Trauma Surgery: A Critical Analysis
De Long, W. G., Einhorn, T. A., Koval, K., McKee, M., Smith, W., Sanders, R., & Watson, T. (2007) · The Journal of Bone & Joint Surgery · doi:10.2106/jbjs.f.00465 · Cited by 570
Metadata
- Authors
- Goodman, S. B., Bauer, T. W., Carter, D., Casteleyn, P. P., Goldstein, S. A., Kyle, R. F., Larsson, S., Stankewich, C. J., Swiontkowski, M. F., Tencer, A. F., Yetkinler, D. N., & Poser, R. D.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1998-03
- Volume
- 348
- Issue
- 348
- Pages
- 42???50
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W1967704766
- Cited by
- 165
- References
- 0
- FWCI
- 8.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Norian SRS Cement Augmentation in Hip Fracture Treatment: Laboratory and Initial Clinical Results. https://app.cochat.ai/papers/10.1097/00003086-199803000-00009
- The paper
- Goodman, S. B., Bauer, T. W., Carter, D., Casteleyn, P. P., Goldstein, S. A., Kyle, R. F., Larsson, S., Stankewich, C. J., Swiontkowski, M. F., Tencer, A. F., Yetkinler, D. N., & Poser, R. D. (1998). Norian SRS Cement Augmentation in Hip Fracture Treatment: Laboratory and Initial Clinical Results. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-199803000-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.