Pedicle Screw Placement Using Image Guided Techniques
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Clinical evaluation of a computer assisted spine surgical system is presented. Eighty pedicle screws were inserted using computer assisted technology in thoracic and lumbar vertebrae for treatment of different types of disorders including fractures, spondylolisthesis, and scoliosis. Fifty-two patients with severe fractures, spondylolisthesis, or pseudoarthrosis of T10 to L5 were treated using a computer assisted technique on 1/2 the patients and performing the screw insertion manually for the other 1/2. At the same time, 28 pedicle screws were inserted in T12 to L4 vertebrae for scoliosis with the help of the computer assisted technique. Surgery was followed in all cases (66 vertebrae; 132 pedicle screws) by postoperative radiographs and computed tomographic examination, on which measurements of screw position relative to pedicle position could be done. For fractures, spondylolisthesis, or pseudarthrosis, comparison between the two groups showed that four screws in 52 (8%) vertebrae had incorrect placement with computer assisted technique whereas 22 screws in 52 (42%) vertebrae had incorrect placement with manual insertion. In patients with scoliosis, four screws in 28 (14%) vertebrae had incorrect placement. In all of the patients (132 pedicle screws) there were no neurologic complications. These results show that a computer assisted technique is much more accurate and safe than manual insertion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Esses, S. I., Sachs, B. L., & Dreyzin, V. (1993) · Spine · doi:10.1097/00007632-199311000-00015 · Cited by 706
NASH, C. L., & MOE, J. H. (1969) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196951020-00002 · Cited by 651
WEINSTEIN, J. N., SPRATT, K. F., SPENGLER, D., BRICK, C., & REID, S. (1988) · Spine · doi:10.1097/00007632-198809000-00008 · Cited by 532
Biomechanics of Thoracolumbar Spinal Fixation: A Review
KRAG, M. H. (1991) · Spine · doi:10.1097/00007632-199103001-00014 · Cited by 212
Foley, K. T., & Smith, M. M. (1996) · Neurosurgery Clinics of North America · doi:10.1016/s1042-3680(18)30385-1 · Cited by 195
Lavallé, S., Sautot, P., Troccaz, J., Cinquin, P., & Merloz, P. (1995) · Journal of Image Guided Surgery · doi:10.1002/(sici)1522-712x(1995)1:1<65::aid-igs10>3.0.co;2-7 · Cited by 169
Self-citationComputer-aided fixation of spinal implants
Nolte, L.-P., Visarius, H., Arm, E., Langlotz, F., Schwarzenbach, O., & Zamorano, L. J. (1995) · Journal of Image Guided Surgery · doi:10.1002/(sici)1522-712x(1995)1:2<88::aid-igs3>3.0.co;2-h · Cited by 167
Computer Assisted Spine Surgery
Merloz, P., Tonetti, J., Eid, A. M., Faure, C., Lavallée, S., Troccaz, J., Sautot, P., Hamadeh, A., & Cinquin, P. (1997) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199704000-00011 · Cited by 105
Self-citation
Cited by
Image-Guided Interventions: Technology Review and Clinical Applications
Cleary, K., & Peters, T. M. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105249 · Cited by 453
Rajasekaran, S., Vidyadhara, S., Ramesh, P., & Shetty, A. P. (2007) · Spine · doi:10.1097/01.brs.0000252094.64857.ab · Cited by 358
Tian, N.-F., Huang, Q.-S., Zhou, P., Zhou, Y., Wu, R.-K., Lou, Y., & Xu, H.-Z. (2011) · European Spine Journal · doi:10.1007/s00586-010-1577-5 · Cited by 345
Worldwide Survey on the Use of Navigation in Spine Surgery
Härtl, R., Lam, K. S., Wang, J., Korge, A., Kandziora, F., & Audigé, L. (2013) · World Neurosurgery · doi:10.1016/j.wneu.2012.03.011 · Cited by 270
Gautschi, O. P., Schatlo, B., Schaller, K., & Tessitore, E. (2011) · Neurosurgical Focus · doi:10.3171/2011.7.focus11168 · Cited by 268
Accuracy Requirements for Image-Guided Spinal Pedicle Screw Placement
Rampersaud, Y. R., Simon, D. A., & Foley, K. T. (2001) · Spine · doi:10.1097/00007632-200102150-00010 · Cited by 224
Image-guided pedicle screw insertion accuracy: a meta-analysis
Tian, N.-F., & Xu, H.-Z. (2009) · International Orthopaedics · doi:10.1007/s00264-009-0792-3 · Cited by 220
“In the studies of our search, a total of 13 in vivo [10, 12, 13, 15, 18, 21, 22, 24 , 25, 27, 32, 35, 36] and nine in vitro [42, 44, 48–51, 53, 55] studies or sub-studies were detected to compare the pedicle screw insertion accuracy between the conventional and navigational methods.”
BackgroundInfluentialSilbermann, J., Riese, F., Allam, Y., Reichert, T., Koeppert, H., & Gutberlet, M. (2011) · European Spine Journal · doi:10.1007/s00586-010-1683-4 · Cited by 214
“However, studies have reported high rates of cortical perforation [13, 19].”
BackgroundImage-guided spine surgery: state of the art and future directions
Tjardes, T., Shafizadeh, S., Rixen, D., Paffrath, T., Bouillon, B., Steinhausen, E. S., & Baethis, H. (2010) · European Spine Journal · doi:10.1007/s00586-009-1091-9 · Cited by 206
“[ 64 , 65] Prospective Th10‐L5 Mixed Dorsal CT matching Accuracy 26/26”
BackgroundClinical Accuracy of Fluoroscopic Computer-Assisted Pedicle Screw Fixation: A CT Analysis
Rampersaud, Y. R., Pik, J. H. T., Salonen, D., & Farooq, S. (2005) · Spine · doi:10.1097/01.brs.0000157490.65706.38 · Cited by 160
“3%, thoracic and lumbar) in the misplacement rates of pedicle screws.(1,9,22,25,27,29,31,32,36,37) In addition to improved accuracy, 3-D CAS systems reduce the range (i.”
Background
Metadata
- Authors
- Merloz, P., Tonetti, J., Pittet, L., Coulomb, M., Lavalle??, S., & Sautot, P.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1998-09
- Volume
- 354
- Issue
- 354
- Pages
- 39-48
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2003231513
- Cited by
- 260
- References
- 8
- FWCI
- 12.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.