Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 160

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Clinical Accuracy of Fluoroscopic Computer-Assisted Pedicle Screw Fixation: A CT Analysis

Rampersaud, Y Raja, Pik, Justin H. T., Salonen, David, Farooq, Samina · 2005 · Spine

Abstract

In Brief Study Design. Observational cohort study with computerized tomography (CT) analysis of in vivo pedicle screw placement. Objective. To evaluate the clinical accuracy of computer-assisted fluoroscopy for the placement of thoracic and lumbosacral (LS) pedicle screws. Summary of Background Data. Computer-assisted fluoroscopy is an adjunct for the placement of pedicle screws. Methods. Postoperative CT of 360 titanium pedicle screws (281 LS [L1–S1]; 79 thoracic [T2–T12]) were independently assessed. All screws were placed using the FluoroNav™ system (Medtronic Surgical Navigation Technologies, Louisville, CO). The relative position of the screw to the pedicle was graded as follows: A = completely in; B = <2 mm breach; C = 2–4 mm breach; and D = >4 mm breach. If an osseous breach occurred, the direction of the breach was further classified. Results. Eight-five percent of screws were completely contained within the pedicle. Fifty-five-pedicle breaches (25 medial; 30 lateral) occurred. Pedicle breaches were graded B in 13.1% (47 breaches), C in 1.9% (7), and D in 0.3% (1) of screws. Pedicle breach was significantly higher in the thoracic compared to the LS spine, 31.6% (25/79) and 10.6% (30/281), respectively (P < 0.0001). In the thoracic spine, 72% of pedicle breaches were lateral. In 49% of breaches, the screw diameter was larger than the pedicle diameter. None of the pedicle breaches were associated with neurologic or other clinical sequelae. Conclusions. The clinical pedicle breach rate in this study is comparable to those reported using conventional techniques with or without fluoroscopic assistance. FluoroNav™ appears to be a safe adjunct for the placement of thoracic and LS pedicle screws. In this series of 360 pedicle screws (T2–S1) placed with the assistance of virtual fluoroscopy, 55 pedicle breaches occurred. The majority of breaches (86%) were minor (<2 mm). None of the pedicle breaches were associated with clinical sequelae. FluoroNav™ system (Medtronic Surgical Navigation Technologies, Louisville, CO) is a safe adjunct for the placement of pedicle screws.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.brs.0000157490.65706.38

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 160

Metadata

Authors
Rampersaud, Y. R., Pik, J. H. T., Salonen, D., & Farooq, S.
Venue
Spine
Published
2005-04
Volume
30
Issue
7
Pages
E183-E190
ISSN
0362-2436 (ISSN-L)
OpenAlex
W1968760086
Cited by
160
References
1
FWCI
7.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical Accuracy of Fluoroscopic Computer-Assisted Pedicle Screw Fixation: A CT Analysis. https://app.cochat.ai/papers/10.1097/01.brs.0000157490.65706.38
The paper
Rampersaud, Y. R., Pik, J. H. T., Salonen, D., & Farooq, S. (2005). Clinical Accuracy of Fluoroscopic Computer-Assisted Pedicle Screw Fixation: A CT Analysis. Spine. https://doi.org/10.1097/01.brs.0000157490.65706.38

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.