The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Relationship of Acetabular Wear to Osteolysis and Loosening in Total Hip Arthroplasty
Abstract
Polyethylene wear and the subsequent development of periprosthetic osteolysis are the major factors limiting the longevity of total hip arthroplasties. A minority eventually loosen, but no clinically applicable system exists for accurate early prediction of failure. The relationship between acetabular wear and the development of loosening, osteolysis, and revision was investigated in 235 Charnley low friction arthroplasties. The average age of the patient at surgery was 31.7 years (range, 17-39 years), and the duration of followup averaged 234 months (19.5 years; range, 74-364 months). Total wear averaged 2.1 mm (range, 0-7.2 mm), and the average wear rate was 0.11 mm per year (range, 0-0.55 mm/year), with the wear rate of revised components being twice that of surviving ones (0.19 mm/year versus 0.09 mm/year). The prevalence of osteolysis (33 hips, 14%) and of acetabular and femoral component loosening and revision rose significantly with increasing wear. Osteolysis also was associated significantly with femoral component loosening and revision, but the presence of calcar changes was not (90 hips, 38%). Twenty-five year survivorship exceeded 90% for arthroplasties with a wear rate less than 0.1 mm per year, but 20-year survivorship of acetabular components with a rate greater than 0.2 mm per year was below 30%, and none survived 25 years. For every additional millimeter of wear, the risk of acetabular revision in any one year increased by 45% and for the femur increased by 32%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,181
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
“Modes of Failure” of Cemented Stem-Type Femoral Components: A Radiographic Analysis of Loosening
Banaszkiewicz, P. A. (2014) · Classic Papers in Orthopaedics · doi:10.1007/978-1-4471-5451-8_8 · Cited by 3,399
Ectopic Ossification Following Total Hip Replacement: INCIDENCE AND A METHOD OF CLASSIFICATION
BROOKER, A. F., BOWERMAN, J. W., ROBINSON, R. A., & RILEY, L. H. (1973) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197355080-00006 · Cited by 2,800
Ectopic Ossification Following Total Hip Replacement: Incidence and a Method of Classification
Banaszkiewicz, P. A. (2014) · Classic Papers in Orthopaedics · doi:10.1007/978-1-4471-5451-8_25 · Cited by 2,537
Radiological Demarcation of Cemented Sockets in Total Hip Replacement
Banaszkiewicz, P. A. (2014) · Classic Papers in Orthopaedics · doi:10.1007/978-1-4471-5451-8_9 · Cited by 2,516
Effect of femoral head size on wear of the polyethylene acetabular component.
Livermore, J., Ilstrup, D., & Morrey, B. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072040-00008 · Cited by 1,024
ARTHROPLASTY OF THE HIP A New Operation
CHARNLEY, J. (1961) · The Lancet · doi:10.1016/s0140-6736(61)92063-3 · Cited by 843
Harris, W. H. (1995) · PubMed · Cited by 732
Karrholm, J., Borssen, B., Lowenhielm, G., & Snorrason, F. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b6.7983118 · Cited by 622
Cited by
Aseptic loosening, not only a question of wear: A review of different theories
Sundfeldt, M., V Carlsson, L., B Johansson, C., Thomsen, P., & Gretzer, C. (2006) · Acta Orthopaedica · doi:10.1080/17453670610045902 · Cited by 622
Moro, T., Takatori, Y., Ishihara, K., Konno, T., Takigawa, Y., Matsushita, T., Chung, U.-I., Nakamura, K., & Kawaguchi, H. (2004) · Nature Materials · doi:10.1038/nmat1233 · Cited by 572
A multispectral three‐dimensional acquisition technique for imaging near metal implants
Koch, K. M., Lorbiecki, J. E., Hinks, R. S., & King, K. F. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21856 · Cited by 269
The Central Role of Wear Debris in Periprosthetic Osteolysis
Purdue, P. E., Koulouvaris, P., Nestor, B. J., & Sculco, T. P. (2006) · HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery · doi:10.1007/s11420-006-9003-6 · Cited by 258
Risk Factors Affecting Outcome of Metal-on-Metal Surface Arthroplasty of the Hip
Beaul??, P. E., Dorey, F. J., LeDuff, M., Gruen, T., & Amstutz, H. C. (2004) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200401000-00015 · Cited by 254
Metadata
- Authors
- Sochart, D. H.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1999-06
- Volume
- 363
- Issue
- 363
- Pages
- 135???150
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2018997404
- Cited by
- 272
- References
- 17
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relationship of Acetabular Wear to Osteolysis and Loosening in Total Hip Arthroplasty. https://app.cochat.ai/papers/10.1097/00003086-199906000-00018
- The paper
- Sochart, D. H. (1999). Relationship of Acetabular Wear to Osteolysis and Loosening in Total Hip Arthroplasty. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-199906000-00018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.