Effect of Rotational Alignment On Patellar Tracking in Total Knee Arthroplasty
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Forty-four consecutive patients (65 knees) who underwent identical condylar type total knee arthroplasty were evaluated retrospectively. In 22 of the patients (32 knees), the femoral component was set parallel to the posterior condylar axis (neutrally aligned group). In the remaining 22 patients (33 knees), it was set in an external rotation position of 3 degrees to 5 degrees relative to the axis (externally aligned group). Of the total knee arthroplasties in the neutrally aligned group, 34% required lateral release, compared with only 6% in the externally aligned group; patellar tracking in the externally aligned group was significantly better than that in the neutrally aligned group. Postoperative measurements performed using computed tomography scans showed that the mean angle between the prosthetic posterior condylar axis and the transepicondylar axis was 7.9 degrees in the neutrally aligned group and 3.2 degrees in the externally aligned group. The external rotation setting of the femoral component diminished the need for lateral retinacular release and may decrease the rate of patellofemoral complications that occur after total knee arthroplasty.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Radiographic analysis of the axial alignment of the lower extremity.
Moreland, J. R., Bassett, L. W., & Hanker, G. J. (1987) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198769050-00016 · Cited by 973
Berger, R. A., Rubash, H. E., Seel, M. J., THOMPSON, W. H., & Crossett, L. S. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199301000-00008 · Cited by 901
The anatomy and functional axes of the femur.
Yoshioka, Y., Siu, D., & Cooke, T. D. (1987) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198769060-00012 · Cited by 508
ANOUCHI, Y. S., WHITESIDE, L. A., KAISER, A. D., & MILLIANO, M. T. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199302000-00027 · Cited by 382
The Effect of Femoral Component Position on Patellar Tracking After Total Knee Arthroplasty
RHOADS, D. D., NOBLE, P. C., REUBEN, J. D., MAHONEY, O. M., & TULLOS, H. S. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199011000-00009 · Cited by 238
Total knee arthroplasty with the kinematic condylar prosthesis. A ten-year follow-up study.
Malkani, A. L., Rand, J. A., Bryan, R. S., & Wallrichs, S. L. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199503000-00012 · Cited by 233
Patellar Component Failure in Cementless Total Knee Arthroplasty
ROSENBERG, A. G., ANDRIACCHI, T. P., BARDEN, R., & GALANTE, J. O. (1988) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198811000-00012 · Cited by 216
Cited by
Matziolis, G., Krocker, D., Weiss, U., Tohtz, S., & Perka, C. (2007) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200702000-00002 · Cited by 429
Gromov, K., Korchi, M., Thomsen, M. G., Husted, H., & Troelsen, A. (2014) · Acta Orthopaedica · doi:10.3109/17453674.2014.940573 · Cited by 242
Anterior knee pain after total knee arthroplasty: a narrative review
Petersen, W., Rembitzki, I. V., Brüggemann, G.-P., Ellermann, A., Best, R., Koppenburg, A. G., & Liebau, C. (2014) · International Orthopaedics · doi:10.1007/s00264-013-2081-4 · Cited by 231
“Some authors see incorrect rotation of the femoral component as the most common cause of patellar complications after TKA [4, 6].”
BackgroundHow precise can bony landmarks be determined on a CT scan of the knee?
Victor, J., Van Doninck, D., Labey, L., Innocenti, B., Parizel, P. M., & Bellemans, J. (2009) · The Knee · doi:10.1016/j.knee.2009.01.001 · Cited by 228
“Failure to obtain correct alignment in total knee arthroplasty leads to inferior results and early revisions [12–21,39–43].”
BackgroundYoshino, N., Takai, S., Ohtsuki, Y., & Hirasawa, Y. (2001) · The Journal of Arthroplasty · doi:10.1054/arth.2001.23621 · Cited by 225
“9 (FT-OA) Akagi et al, 1999 [2] 6.”
BackgroundMethodInfluential
Metadata
- Authors
- Akagi, M., Matsusue, Y., Mata, T., Asada, Y., Horiguchi, M., Iida, H., & Nakamura, T.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1999-09
- Volume
- 366
- Issue
- 366
- Pages
- 155-163
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2076500321
- Cited by
- 358
- References
- 7
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.