A Quick Surgical Technique for Deep, Anterior Lamellar Keratoplasty Using Visco-dissection
Abstract
PURPOSE: To describe a new surgical technique for deep, anterior lamellar keratoplasty using a viscoelastic for dissection of Descemet's membrane (DM) from the posterior stroma. METHODS: Through a paracentesis, aqueous was exchanged by air to visualize the posterior corneal surface-i.e., the air-to-endothelium interface. Using the interface as a reference plane, a 30 gauge needle was inserted into the cornea to just anterior to DM. Viscoelastic was injected to separate DM from the posterior stroma, and a recipient, anterior lamella was excised. A full-thickness donor button was sutured into the recipient bed, after stripping its DM. RESULTS: In 25 eye bank eyes, the procedure could be completed in 20 eyes; in 5 eyes, DM ruptured during visco-dissection. With light microscopy, dissection depth was located at the level of DM. In two patient eyes the procedure could be completed. In a third patient eye DM ruptured during visco-dissection, and the procedure was converted into a penetrating keratoplasty. CONCLUSION: Using visco-dissection, a lamellar keratoplasty can be performed quickly, with the donor-to-recipient interface just above the recipient DM, i.e., with a nearly perfect anatomical replacement of all corneal stroma. There is substantial risk of rupture or microperforation of DM during surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Big-bubble technique to bare Descemet's membrane in anterior lamellar keratoplasty
Anwar, M., & Teichmann, K. D. (2002) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(01)01181-6 · Cited by 766
Deep Anterior Lamellar Keratoplasty as an Alternative to Penetrating Keratoplasty
Reinhart, W. J., Musch, D. C., Jacobs, D. S., Lee, W. B., Kaufman, S. C., & Shtein, R. M. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2010.11.002 · Cited by 538
Quality of Vision and Graft Thickness in Deep Anterior Lamellar and Penetrating Corneal Allografts
Ardjomand, N., Hau, S., McAlister, J. C., Bunce, C., Galaretta, D., Tuft, S. J., & Larkin, D. F. P. (2007) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.10.043 · Cited by 257
Dissection plane in deep anterior lamellar keratoplasty using the big-bubble technique
Jafarinasab, M. R., Rahmati-Kamel, M., Kanavi, M. R., & Feizi, S. (2010) · Cornea · doi:10.1097/ico.0b013e3181ba7016 · Cited by 57
McKee, H. D., Irion, L. C. D., Carley, F. M., Jhanji, V., & Brahma, A. K. (2011) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2011-300360 · Cited by 44
Metadata
- Authors
- Melles, G. R. J., Remeijer, L., Geerards, A. J. M., & Beekhuis, W. H.
- Venue
- Cornea
- Published
- 2000-07
- Volume
- 19
- Issue
- 4
- Pages
- 427-432
- ISSN
- 0277-3740 (ISSN-L)
- OpenAlex
- W2065116655
- Cited by
- 213
- References
- 0
- FWCI
- 8.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Quick Surgical Technique for Deep, Anterior Lamellar Keratoplasty Using Visco-dissection. https://app.cochat.ai/papers/10.1097/00003226-200007000-00004
- The paper
- Melles, G. R. J., Remeijer, L., Geerards, A. J. M., & Beekhuis, W. H. (2000). A Quick Surgical Technique for Deep, Anterior Lamellar Keratoplasty Using Visco-dissection. Cornea. https://doi.org/10.1097/00003226-200007000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.