Corneal Endothelial Cell Damage from Glaucoma Drainage Device Materials
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
PURPOSE: To compare the level of endothelial damage caused by contact with materials used in contemporary glaucoma drainage devices and a phosphorylcholine polymer-coated PMMA (PC-PMMA). METHODS Standard-sized discs of silicone, PMMA (polymethylmethacrylate), and PC-PMMA (n = 6) were gently lowered onto cultured bovine corneal endothelial (BCE) monolayers using a vacuum suction device. A 2.4-g stainless steel cloning ring weight was then placed on top of each disc. The weights and discs were removed using a vacuum suction device and forceps after 5 minutes of contact. A 0.4% trypan blue solution was used to stain the cell monolayer to visualize the area of cell damage. The total area of damage in each well (including the area stripped of cells) was measured using an image processor and expressed as a percentage of the total disc area to derive a damage coefficient for each material. Damage coefficients for different materials were compared using Bonferroni corrected analysis of variance (ANOVA). RESULTS: Percentage of areas of damage (mean +/- SD) after standardized contact were as follows: PMMA, 5.95 +/- 4.60%; silicone, 3.08 +/- 2.68%; PC-PMMA, 0.15 +/- 0.25%. PMMA caused marked endothelial cell damage. PC-PMMA discs produced a significantly lower level (p = 0.04) of endothelial cell trauma. CONCLUSION: Our results suggest that PC coating technology may be effective in reducing the rate of corneal endothelial failure following GDD implantation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Biomembrane surfaces as models for polymer design: the potential for haemocompatibility
Hayward, J. A., & Chapman, D. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90047-4 · Cited by 391 · cited 1×
“The phosphorylcholine moiety is the highly hydrophilic head group of the predominant phospholipids (lecithin and sphingomyelins) in the outer envelope of mammalian cells.(7) As coatings or bulk materials, biomimetic polymers are thought to have enhanced resistance for protein and cell adhesion.”
BackgroundGlaucoma drainage devices; past, present, and future
Lim, K. S., Allan, B. D. S., Lloyd, A. W., Muir, A., Khaw, P. T., LIM, K. S., ALLAN, B. D. S., LLOYD, A. W., MUIR, A., & KHAW, P. T. (1998) · British Journal of Ophthalmology · doi:10.1136/bjo.82.9.1083 · Cited by 186
Self-citationChemical and Mechanical Requirements for Fibroblast Adhesion
Maroudas, N. G. (1973) · Nature · doi:10.1038/244353a0 · Cited by 143
Beebe, W. E., Starita, R. J., Fellman, R. L., Lynn, J. R., & Gelender, H. (1990) · Ophthalmology · doi:10.1016/s0161-6420(90)32393-x · Cited by 83 · cited 1×
“34% of cases after a mean follow-up of 2 years in GDD implantation after previous corneal graft surgery.(2)”
BackgroundKaufman, H. E., Katz, J. I., Valenti, J., Sheets, J. W., & Goldberg, E. P. (1977) · Science · doi:10.1126/science.910147 · Cited by 73 · cited 1×
“Relatively hydrophobic surfaces such as PMMA were found to be damaging to the endothelium in the 1970s when the prevalence of pseudophakic bullous keratopathy began to increase.(14) Further in vitro experimentation confirmed that hydrophilic surface modification of PMMA or substitution with more hydrophilic polymers c…”
BackgroundCorneal Endothelial Loss with New Intraocular Lenses
Barrett, G. D., & Constable, I. J. (1984) · American Journal of Ophthalmology · doi:10.1016/0002-9394(87)90350-3 · Cited by 51
Relating the surface properties of intraocular lens materials to endothelial cell adhesion damage.
Mateo, N. B., & Ratner, B. D. (1989) · PubMed · Cited by 36
Surface modification of intraocular lenses to reduce corneal endothelial damage
Knight, P. M., & Link, W. J. (1979) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0146-2776(79)80051-8 · Cited by 29
The development of in vitro biocompatibility tests for the evaluation of intraocular biomaterials
Lloyd, A. W., Dropcova, S., Faragher, R., Gard, P. R., Hanlon, G. W., Mikhalovsky, S. V., Olliff, C. J., Denyer, S. P., Letko, E., & Filipec, M. (1999) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1008935707910 · Cited by 27
The rate of adhesion of melanoma cells onto nonionic polymer surfaces
Yasuda, H. K., Yamanashi, B. S., & Devito, D. P. (1978) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820120510 · Cited by 27 · cited 1×
“These include surface hydrophilicity,(11) specific surface chemistry,(11) surface rigidity,(12) and surface energy.(13) Relatively hydrophobic surfaces such as PMMA were found to be damaging to the endothelium in the 1970s when the prevalence of pseudophakic bullous keratopathy began to increase.”
Background
Research works printed but not linked: 2
- Mateo, 1989, Invest Ophthalmol Vis Sci, 30, 853
- Hunter, 1993, Soc Thorac Surg, &NA;, 1329
Cited by
Kim, C. S., Yim, J. H., Lee, E. K., & Lee, N. H. (2008) · Clinical and Experimental Ophthalmology · doi:10.1111/j.1442-9071.2008.01683.x · Cited by 111
The long-term results of keratoplasty in eyes with a glaucoma drainage device
Alvarenga, L. S., Mannis, M. J., Brandt, J. D., Lee, W. B., Schwab, I. R., & Lim, M. C. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.02.058 · Cited by 106
Corneal complications of glaucoma surgery
Hau, S., & Barton, K. (2009) · Current Opinion in Ophthalmology · doi:10.1097/icu.0b013e328325a54b · Cited by 102
Mini drug pump for ophthalmic use
Saati, S., Lo, R., Li, P.-Y., Meng, E., Varma, R., & Humayun, M. S. (2010) · Current Eye Research · doi:10.3109/02713680903521936 · Cited by 77
Graft failure: III. Glaucoma escalation after penetrating keratoplasty
Greenlee, E. C., & Kwon, Y. H. (2008) · International Ophthalmology · doi:10.1007/s10792-008-9223-5 · Cited by 71
Mendrinos, E., Dosso, A., Sommerhalder, J., & Shaarawy, T. M. (2008) · Eye · doi:10.1038/eye.2008.321 · Cited by 52
Jabłońska, J., Lewczuk, K., Konopińska, J., Mariak, Z., & Rękas, M. (2021) · Acta Ophthalmologica · doi:10.1111/aos.14906 · Cited by 44
“In studies of animal models, it was noted that the material of the drainage device affects the degree of cell loss (Lim 2003).”
BackgroundKonopińska, J., Deniziak, M., Saeed, E., Bartczak, A., Zalewska, R., Mariak, Z., & Rękas, M. (2015) · Journal of Ophthalmology · doi:10.1155/2015/720109 · Cited by 31
Ateş, H., Palamar, M., Yağcı, A., & Eğrilmez, S. (2010) · Journal of Glaucoma · doi:10.1097/ijg.0b013e3181ca76d9 · Cited by 24
“The amount of endothelial cell damage caused by the tube implantation both at the time of surgery and in association with subsequent micromotion, probably varies with physical force and the area of contact.(22) As Ex-PRESS mini glaucoma shunt is a steel material it is more stable than other GDDs such as Ahmed valve an…”
BackgroundSurgical Management for Postkeratoplasty Glaucoma
Tandon, A., Espandar, L., Cupp, D. G., Ho, S., Johnson, V., & Ayyala, R. S. (2012) · Journal of Glaucoma · doi:10.1097/ijg.0b013e31827a0712 · Cited by 22
Surgical Outcomes of DSAEK in Patients with Prior Ahmed Glaucoma Drainage Device Placement
Schoenberg, E. D., Levin, K. H., Savetsky, M. J., Mcintire, L. U., & Ayyala, R. S. (2013) · European Journal of Ophthalmology · doi:10.5301/ejo.5000326 · Cited by 19
Post penetrating keratoplasty glaucoma – A review
Gupta, P., Sharma, A., & Ichhpujani, P. (2014) · Nepalese Journal of Ophthalmology · doi:10.3126/nepjoph.v6i1.10776 · Cited by 18
Glaucoma Escalation after Penetrating Keratoplasty
Mansour, A. M. (2010) · Iranian Journal of Ophthalmology · Cited by 17
Chiam, P. J. T., Cheeseman, R., Ho, V. W. M., Romano, V., Choudhary, A., Batterbury, M., Kaye, S. B., & Willoughby, C. E. (2017) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-017-3612-2 · Cited by 16
Li, J., Taylor, M., & Zhang, Z. (2017) · Springer eBooks · doi:10.1007/978-3-319-57494-3_8 · Cited by 12
Near infra-red light attenuates corneal endothelial cell dysfunction in situ and in vitro
Núñez‐Álvarez, C., del Olmo‐Aguado, S., Merayo-Llovés, J., & Osborne, N. N. (2017) · Experimental Eye Research · doi:10.1016/j.exer.2017.06.008 · Cited by 13
Hypotony Keratopathy Following Trabeculectomy
Camp, A. S., & Weinreb, R. N. (2019) · Journal of Glaucoma · doi:10.1097/ijg.0000000000001425 · Cited by 12
Angle-Closure Glaucoma after Piggyback Intraocular Lens Implantation
García-Feijoo, J., Saenz-Frances, F., Martínez-de-la-Casa, J. M., Mendez-Hernandez, C. D., Fernández-Vidal, A., Elías-De-Tejada, M., Reche-Frutos, J., & Garcia-Sanchez, J. (2008) · European Journal of Ophthalmology · doi:10.1177/112067210801800528 · Cited by 12
“placement in the anterior chamber since this would have meant continuous contact between the tube and the corneal endothelium (15).”
BackgroundCorneal Endothelial Transplantation in Uveitis: Incidence and Risk Factors
Roldan, A., Zebardast, N., Pistilli, M., Khachatryan, N., Payal, A. R., Begum, H. A., Artornsombudh, P., Pujari, S. S., Rosenbaum, J. T., Sen, H. N., et al. (2021) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2021.10.031 · Cited by 11
Murakami, Y., Hirooka, K., Yuasa, Y., Okumichi, H., Tokumo, K., Kawano, R., & Kiuchi, Y. (2020) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2020-316379 · Cited by 8
From design to Deployment: The innovative role of nanomicelles in targeted ophthalmic therapeutics
Sun, M., Wang, J., Fan, W., Wang, K., Wang, Y., Zhang, J., Ding, S., Zhang, C., Feng, Z., Wang, Y.-G., et al. (2025) · Materials today. Bio · doi:10.1016/j.mtbio.2025.102537 · Cited by 7
“Continued minute movements of the tube element relevant to the cornea and macroscopic contact of the cornea with an improperly positioned long tube are among the most prevalent causes of early postoperative damage [88].”
Biomedical Applications of Biomimetic Polymers: The Phosphorylcholine‐Containing Polymers
Lewis, A., & Lloyd, A. (2012) · Wiley eBooks · doi:10.1002/9781118129906.ch4 · Cited by 8
Glaucoma Mini-Shunt Implantation After Keratoplasty
Ledesma‐Gil, J., García-Rodríguez, M. D. L. Á., Gurria, L. U., Graue-Hernández, E. O., & Navas, A. (2016) · Journal of Glaucoma · doi:10.1097/ijg.0000000000000413 · Cited by 6
Ateş, H., Palamar, M., Yağcı, A., & Eğrilmez, S. (2015) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2015.11.012 · Cited by 5
Morita, S., Hamanaka, T., Sakurai, T., Watanabe, S., Sakanishi, Y., Ishida, N., & Ebihara, N. (2023) · BMC Ophthalmology · doi:10.1186/s12886-023-03247-y · Cited by 4
“…contact of the tube to the cornea at its insertion point [29], the distance of the tube tip to the cornea [30], a change in the location of the tube during the postoperative time course [31], a foreign body reaction against the tube material [32], or turbulence at the tip of the silicon tube [33].”
BackgroundGlaucoma Drainage Implant Surgery and Ocular Surface Transplant Graft Preservation
Aref, A. A., Sivaraman, K. R., & Djalilian, A. R. (2013) · Seminars in Ophthalmology · doi:10.3109/08820538.2013.835840 · Cited by 4
Oliveira, J. A. D. M. M., Oliveira, V. D. M. M., & Cronemberger, S. (2022) · Revista Brasileira de Oftalmologia · doi:10.37039/1982.8551.20220041 · Cited by 4
Les adjuvants à la chirurgie non perforante: drains et implants
Roy, S., & Mermoud, A. (2006) · Journal Français d Ophtalmologie · doi:10.1016/s0181-5512(06)73917-1 · Cited by 3
The Effects of Primary Pterygium on Corneal Endothelial Cells Density in Iraqi Eyes
Kareem, A. A., Mehdy, I. S., & Alrubaye, H. S. (2021) · Journal of Ophthalmology and Advance Research · doi:10.46889/joar.2021.2201 · Cited by 2
Glaucoma Associated with Penetrating Keratoplasty
Leelachaikul, Y., Waiyawuth, T., Ruangsuksriwong, V., & Methasiri, S. (2005)
Ateş, H., Palamar, M., Yağcı, A., & Eğrilmez, S. (2016) · International Ophthalmology · doi:10.1007/s10792-016-0182-y
Management of Glaucoma in Patients with Ocular Surface Disease
Ghahari, E., Djalilian, A. R., & Aref, A. A. (2017) · Springer eBooks · doi:10.1007/978-3-319-15823-5_9
Jacobovitz, S., Oliveira, J. A. D. M. M., & Cronemberger, S. (2018) · European Journal of Ophthalmology · doi:10.1177/1120672118815066
An Optimized Mechanical Peeling Protocol for Mouse Corneal Endothelium
Song, Z., Song, L., & Mei, H. (2026) · Bioengineering · doi:10.3390/bioengineering13080869
Metadata
- Authors
- Lim, K. S.
- Affiliations
- Biocompatibles (United Kingdom) (GB)
- Corresponding author
- Lim, K. Sheng
- ORCID
- Lim, K. Sheng
- Venue
- Cornea
- Published
- 2003-05
- Volume
- 22
- Issue
- 4
- Pages
- 352-354
- ISSN
- 0277-3740 (ISSN-L)
- OpenAlex
- W2160813618
- Semantic Scholar
- 8163bcb666d436013cd84921de0579c0a279da0c
- Cited by
- 35
- References
- 12
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 1 · 2022: 1 · 2021: 3 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 4 · 2016: 2 · 2015: 2 · 2014: 1 · 2013: 2 · 2012: 2
- FWCI
- 1.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Cornea (publishedVersion)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- University of Brighton Repository (University of Brighton) (submittedVersion)
- Topics
- Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
- Health Sciences › Medicine › Ophthalmology › Corneal surgery and disorders
- Health Sciences › Medicine › Ophthalmology › Intraocular Surgery and Lenses
- Keywords
- glaucoma drainage devices, corneal endothelial cell damage, phosphorylcholine coating, PMMA, silicone, biocompatibility, endothelial monolayer, trypan blue staining
- MeSH terms
- Animals, Cattle, Cell Line, Drainage, Endothelium, Corneal, Glaucoma, Phosphorylcholine, Polymers, Silicones, Polymethyl Methacrylate, Coated Materials, Biocompatible
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.