Glaucoma drainage devices; past, present, and future
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Glaucoma filtration surgery (GFS) has been shown to be more effective at preventing disease progression than other primary treatment modalities in open angle glaucoma.1 2 If it were possible to avoid complications associated with poor flow control, primary GFS would probably be offered more widely. Trabeculectomy, the procedure of choice in conventional GFS, has remained essentially unchanged for over a quarter of a century. Local control over wound healing with antimetabolite agents such as 5-fluorouracil and mitomycin C has improved the prognosis for cases with high risk of filtration failure; but flow control remains inexact despite the introduction of a variety of suture adjustment techniques. Glaucoma drainage devices (GDDs) have the potential to regulate flow consistently, eliminating hypotony after GFS. Design, material, and manufacturing deficiencies have left this potential unfulfilled in existing GDDs, all of which exhibit problems with poor flow control and suboptimal tissue compatibility. The role of GDDs in contemporary GFS remains poorly defined, but possibilities offered by new biomaterials and the goal of accurate flow control have stimulated considerable recent interest in GDD development. This review traces the progress of GDD design through to the present and beyond. In 1906, horse hair3 was placed through a corneal paracentesis in an attempt to drain a hypopyon externally. The same technique was later used to treat two patients with painful absolute glaucoma.4 Sporadic attempts using implants to shunt aqueous to a variety of unconventional sites, including the vortex veins5 and the nasolacrimal duct,6 have since been reported. Results were generally unfavourable or too poorly documented to evaluate, and attention has focused on devices shunting aqueous fluid to the subconjunctival space as with conventional GFS. The first translimbal GDD, reported by Zorab7 in 1912, was silk thread used as a seton to aid drainage …
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface modification of polymers for medical applications
Ikada, Y. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90025-6 · Cited by 674
Five-year Follow-up of the Fluorouracil Filtering Surgery Study
THE FLUOROURACIL FILTERING SURGERY STUDY GROUP (1996) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)70431-3 · Cited by 526
Intraoperative Mitomycin versus Postoperative 5-Fluorouracil in High-risk Glaucoma Filtering Surgery
Skuta, G. L., Beeson, C. C., Higginbotham, E. J., Lichter, P. R., Musch, D. C., Bergstrom, T. J., Klein, T. B., & Falck, F. Y. (1992) · Ophthalmology · doi:10.1016/s0161-6420(92)31951-7 · Cited by 477
Fibrin(ogen) mediates acute inflammatory responses to biomaterials.
Tang, L., & Eaton, J. W. (1993) · The Journal of experimental medicine · doi:10.1084/jem.178.6.2147 · Cited by 449
Why Do Some People Go Blind from Glaucoma?
Grant, W. M., & Burke, J. F. (1982) · Ophthalmology · doi:10.1016/s0161-6420(82)34675-8 · Cited by 390 · cited 1×
“49 50 Another important caveat concerns attrition rates, or continued increments in the proportion of filtration failures with lengthening postoperative follow up.”
BackgroundMao, L. K., Stewart, W. C., & Shields, M. B. (1991) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)76896-5 · Cited by 223
Jay, J. L., & Allan, D. (1989) · Eye · doi:10.1038/eye.1989.84 · Cited by 163
Long-term Survival of Molteno Glaucoma Drainage Devices
Mills, R. P., Reynolds, A. C., Emond, M. J., Barlow, W. E., & Leen, M. M. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30700-8 · Cited by 154 · cited 1×
“Mills et al 39 (Table 3) reported a 10% failure rate per postoperative year in a series including longer term follow up for single and double plate Molteno tubes.”
BackgroundExperience with the Baerveldt Glaucoma Implant in Treating Neovascular Glaucoma
Sidoti, P. A., Dunphy, T. R., Baerveldt, G., LABREE, L. D., Minckler, D. S., Lee, P. P., & Heuer, D. K. (1995) · Ophthalmology · doi:10.1016/s0161-6420(95)30904-9 · Cited by 148
Motteno Tube Implantation for Neovascular Glaucoma
Mermoud, A., Salmon, J. F., Alexander, P., Straker, C., & Murray, A. D. N. (1993) · Ophthalmology · doi:10.1016/s0161-6420(93)31557-5 · Cited by 131
Cited by
Ocular biomaterials and implants
Lloyd, A. W., Faragher, R. G. A., & Denyer, S. P. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00237-4 · Cited by 313
Self-citationColeman, A. L. (1999) · The Lancet · doi:10.1016/s0140-6736(99)04240-3 · Cited by 210
Medical versus surgical interventions for open angle glaucoma
Burr, J., Azuara-Blanco, A., Avenell, A., & Tuulonen, A. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004399.pub3 · Cited by 209
Corneal endothelial cell damage from glaucoma drainage device materials
Lim, K. S. (2003) · Cornea · doi:10.1097/00003226-200305000-00013 · Cited by 35
Self-citation
Metadata
- Authors
- Lim, K. S., Allan, B. D. S., Lloyd, A. W., Muir, A., Khaw, P. T., LIM, K. S., ALLAN, B. D. S., LLOYD, A. W., MUIR, A., & KHAW, P. T.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 1998-09-01
- Volume
- 82
- Issue
- 9
- Pages
- 1083-1089
- ISSN
- 0007-1161 (ISSN-L)
- OpenAlex
- W2024577563
- Cited by
- 186
- References
- 15
- FWCI
- 3.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Glaucoma drainage devices; past, present, and future. https://app.cochat.ai/papers/10.1136/bjo.82.9.1083
- The paper
- Lim, K. S., Allan, B. D. S., Lloyd, A. W., Muir, A., Khaw, P. T., LIM, K. S., ALLAN, B. D. S., LLOYD, A. W., MUIR, A., & KHAW, P. T. (1998). Glaucoma drainage devices; past, present, and future. British Journal of Ophthalmology. https://doi.org/10.1136/bjo.82.9.1083
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.