The Repeatability of Clinical Measurements of Dry Eye
Abstract
PURPOSE: The repeatability of individual dry eye diagnostic tests has been reported in the literature on normal samples of patients and to a lesser degree in dry eye patients. In this study, the repeatability of a battery of clinical diagnostic tests for dry eye was assessed on mild to moderate dry eye patients. METHODS: A dry eye examination was performed on 75 patients on two occasions by a single examiner. The battery of dry eye tests included symptom assessment, contact lens and medical history, slit-lamp biomicroscopic evaluation of the eyelids, evaluation of Meibomian glands, assessment of tear film quality, tear meniscus height, assessment of blink quality, fluorescein tear breakup time (TBUT), fluorescein and rose bengal staining of the cornea and conjunctiva, phenol red thread test, and Schirmer test. RESULTS: The repeatability of subjective report of dryness (kappaW = 0.62) and grittiness (kappaW = 0.73) was moderate to high. In contrast, the repeatability of Meibomian gland disease classification (kappaW = 0.20), presence or absence of inferior corneal fluorescein staining (kappa = 0.25), and inferior conjunctival rose bengal staining (kappa = 0.21) was poor. When a summed staining score of corneal and conjunctival regions was evaluated, weighted kappa reliability was fair. The repeatability of tear breakup time was substantial [95% limits of agreement -5.71 to 5.83 seconds; intraclass coefficient coefficient (ICC) 0.65], and improved when the two timed readings were averaged. Repeatability of the Schirmer test is more variable as wetting scores increase. When the average Schirmer scores </= 10 mm were evaluated, moderate repeatability was demonstrated, indicating that the test performs better with more advanced disease. CONCLUSION: Although patient-reported symptoms are moderately repeatable from visit to visit, many of the procedures clinically used to diagnose and monitor dry eye syndromes are largely unrepeatable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A Coefficient of Agreement for Nominal Scales
Cohen, J. (1960) · Educational and Psychological Measurement · doi:10.1177/001316446002000104 · Cited by 42,398
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Weighted kappa: nominal scale agreement provision for scaled disagreement or partial credit
Cohen, J. (1968) · Psychological Bulletin · doi:10.1037/h0026256 · Cited by 8,736
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Large sample standard errors of kappa and weighted kappa.
Fleiss, J. L., Cohen, J., & Everitt, B. S. (1969) · Psychological Bulletin · doi:10.1037/h0028106 · Cited by 1,520
Bland, J. M., & Altman, D. G. (1990) · Computers in Biology and Medicine · doi:10.1016/0010-4825(90)90013-f · Cited by 691
Statistical evaluation of agreement between two methods for measuring a quantitative variable
Lee, J., Koh, D., & Ong, C. N. (1989) · Computers in Biology and Medicine · doi:10.1016/0010-4825(89)90036-x · Cited by 473
Meibomian gland disease. Classification and grading of lid changes
Bron, A. J., Benjamin, L., & Snibson, G. R. (1991) · Eye · doi:10.1038/eye.1991.65 · Cited by 376
Cited by
TFOS DEWS II Epidemiology Report
Stapleton, F., Alves, M., Bunya, V. Y., Jalbert, I., Lekhanont, K., Malet, F., Na, K.-S., Schaumberg, D., Uchino, M., Vehof, J., et al. (2017) · The Ocular Surface · doi:10.1016/j.jtos.2017.05.003 · Cited by 2,618
TFOS DEWS II Diagnostic Methodology report
Wolffsohn, J. S., Arita, R., Chalmers, R., Djalilian, A., Dogru, M., Dumbleton, K., Gupta, P. K., Karpecki, P., Lazreg, S., Pult, H., et al. (2017) · The Ocular Surface · doi:10.1016/j.jtos.2017.05.001 · Cited by 2,122
Paulsen, A. J., Cruickshanks, K. J., Fischer, M. E., Huang, G.-H., Klein, B. E. K., Klein, R., & Dalton, D. S. (2014) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2013.12.023 · Cited by 404
A Randomized Controlled Trial of Omega 3 Fatty Acids in Rosacea Patients with Dry Eye Symptoms
Bhargava, R., Chandra, M., Bansal, U., Singh, D., Ranjan, S., & Sharma, S. (2016) · Current Eye Research · doi:10.3109/02713683.2015.1122810 · Cited by 67
Metadata
- Authors
- Nichols, K. K., Mitchell, G. L., & Zadnik, K.
- Venue
- Cornea
- Published
- 2004-04
- Volume
- 23
- Issue
- 3
- Pages
- 272-285
- ISSN
- 0277-3740 (ISSN-L)
- OpenAlex
- W2078501398
- Cited by
- 493
- References
- 12
- FWCI
- 9.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Repeatability of Clinical Measurements of Dry Eye. https://app.cochat.ai/papers/10.1097/00003226-200404000-00010
- The paper
- Nichols, K. K., Mitchell, G. L., & Zadnik, K. (2004). The Repeatability of Clinical Measurements of Dry Eye. Cornea. https://doi.org/10.1097/00003226-200404000-00010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.