The Repeatability of Clinical Measurements of Dry Eye

Nichols, Kelly K., Mitchell, G. Lynn, Zadnik, Karla·2004·Cornea

Abstract

PURPOSE: The repeatability of individual dry eye diagnostic tests has been reported in the literature on normal samples of patients and to a lesser degree in dry eye patients. In this study, the repeatability of a battery of clinical diagnostic tests for dry eye was assessed on mild to moderate dry eye patients. METHODS: A dry eye examination was performed on 75 patients on two occasions by a single examiner. The battery of dry eye tests included symptom assessment, contact lens and medical history, slit-lamp biomicroscopic evaluation of the eyelids, evaluation of Meibomian glands, assessment of tear film quality, tear meniscus height, assessment of blink quality, fluorescein tear breakup time (TBUT), fluorescein and rose bengal staining of the cornea and conjunctiva, phenol red thread test, and Schirmer test. RESULTS: The repeatability of subjective report of dryness (kappaW = 0.62) and grittiness (kappaW = 0.73) was moderate to high. In contrast, the repeatability of Meibomian gland disease classification (kappaW = 0.20), presence or absence of inferior corneal fluorescein staining (kappa = 0.25), and inferior conjunctival rose bengal staining (kappa = 0.21) was poor. When a summed staining score of corneal and conjunctival regions was evaluated, weighted kappa reliability was fair. The repeatability of tear breakup time was substantial [95% limits of agreement -5.71 to 5.83 seconds; intraclass coefficient coefficient (ICC) 0.65], and improved when the two timed readings were averaged. Repeatability of the Schirmer test is more variable as wetting scores increase. When the average Schirmer scores </= 10 mm were evaluated, moderate repeatability was demonstrated, indicating that the test performs better with more advanced disease. CONCLUSION: Although patient-reported symptoms are moderately repeatable from visit to visit, many of the procedures clinically used to diagnose and monitor dry eye syndromes are largely unrepeatable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003226-200404000-00010

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 493

Metadata

Authors
Nichols, K. K., Mitchell, G. L., & Zadnik, K.
Venue
Cornea
Published
2004-04
Volume
23
Issue
3
Pages
272-285
ISSN
0277-3740 (ISSN-L)
OpenAlex
W2078501398
Cited by
493
References
12
FWCI
9.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Repeatability of Clinical Measurements of Dry Eye. https://app.cochat.ai/papers/10.1097/00003226-200404000-00010
The paper
Nichols, K. K., Mitchell, G. L., & Zadnik, K. (2004). The Repeatability of Clinical Measurements of Dry Eye. Cornea. https://doi.org/10.1097/00003226-200404000-00010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.