The DOI matches its Crossref record.
Comparison of ear-based, bladder, oral, and axillary methods for core temperature measurement
Abstract
OBJECTIVE: To determine the accuracy and repeatability of ear-based, bladder, oral, and axillary temperature methods. DESIGN: Prospective, descriptive comparison of the accuracy of four temperature methods in relation to pulmonary artery temperature and the repeatability of each method. SETTING: Critical care units of a university teaching hospital. PATIENTS: Convenience sample of 38 adult patients with indwelling pulmonary artery thermistor catheters. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Ear-based estimates of core temperature with an infrared thermometer and pulmonary artery, bladder, oral, and axillary temperatures with thermistor-based instruments were made every 20 mins for 4 hrs. Mean offsets (+/- SD) from pulmonary artery temperature for each method were as follows: ear-based 0.07 +/- 0.41 degrees C; bladder 0.03 +/- 0.23 degrees C; oral 0.05 +/- 0.26 degrees C; and axillary -0.68 +/- 0.57 degrees C. The accuracy of each method varied with the level of pulmonary artery temperature. Repeated measurements with all four methods had mean SD values within +/- 0.2 degrees C. CONCLUSIONS: Infrared ear thermometry provided a relatively close estimate of pulmonary artery core temperature, although with more variability than bladder or oral methods, while axillary readings were substantially lower than the pulmonary artery temperature and highly variable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mohanty, S., Rosenthal, R. A., Russell, M. M., Neuman, M. D., Ko, C. Y., & Esnaola, N. F. (2016) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2015.12.026 · Cited by 625
O’Grady, N. P., Barie, P. S., Bartlett, J. G., Bleck, T., Carroll, K., Kalil, A. C., Linden, P., Maki, D. G., Nierman, D., Pasculle, W., et al. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e318169eda9 · Cited by 600
Lefrant, J.-Y., Muller, L., de La Coussaye, J. E., Benbabaali, M., Lebris, C., Zeitoun, N., Mari, C., Saïssi, G., Ripart, J., & Eledjam, J.-J. (2003) · Intensive Care Medicine · doi:10.1007/s00134-002-1619-5 · Cited by 303
Hoedemaekers, C. W., Ezzahti, M., Gerritsen, A., & van der Hoeven, J. G. (2007) · Critical Care · doi:10.1186/cc6104 · Cited by 293
Fever after subarachnoid hemorrhage: Risk factors and impact on outcome
Fernandez, A., Schmidt, J. M., Claassen, J., Pavlicova, M., Huddleston, D., Kreiter, K. T., Ostapkovich, N. D., Kowalski, R. G., Parra, A., Connolly, E. S., et al. (2007) · Neurology · doi:10.1212/01.wnl.0000258543.45879.f5 · Cited by 262
Metadata
- Authors
- ERICKSON, R. S., & KIRKLIN, S. K.
- Venue
- Critical Care Medicine
- Published
- 1993-10
- Volume
- 21
- Issue
- 10
- Pages
- 1528-1534
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1973251111
- Cited by
- 189
- References
- 0
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of ear-based, bladder, oral, and axillary methods for core temperature measurement. https://app.cochat.ai/papers/10.1097/00003246-199310000-00022
- The paper
- ERICKSON, R. S., & KIRKLIN, S. K. (1993). Comparison of ear-based, bladder, oral, and axillary methods for core temperature measurement. Critical Care Medicine. https://doi.org/10.1097/00003246-199310000-00022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.