Comparison of ear-based, bladder, oral, and axillary methods for core temperature measurement
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To determine the accuracy and repeatability of ear-based, bladder, oral, and axillary temperature methods. DESIGN: Prospective, descriptive comparison of the accuracy of four temperature methods in relation to pulmonary artery temperature and the repeatability of each method. SETTING: Critical care units of a university teaching hospital. PATIENTS: Convenience sample of 38 adult patients with indwelling pulmonary artery thermistor catheters. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Ear-based estimates of core temperature with an infrared thermometer and pulmonary artery, bladder, oral, and axillary temperatures with thermistor-based instruments were made every 20 mins for 4 hrs. Mean offsets (+/- SD) from pulmonary artery temperature for each method were as follows: ear-based 0.07 +/- 0.41 degrees C; bladder 0.03 +/- 0.23 degrees C; oral 0.05 +/- 0.26 degrees C; and axillary -0.68 +/- 0.57 degrees C. The accuracy of each method varied with the level of pulmonary artery temperature. Repeated measurements with all four methods had mean SD values within +/- 0.2 degrees C. CONCLUSIONS: Infrared ear thermometry provided a relatively close estimate of pulmonary artery core temperature, although with more variability than bladder or oral methods, while axillary readings were substantially lower than the pulmonary artery temperature and highly variable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mohanty, S., Rosenthal, R. A., Russell, M. M., Neuman, M. D., Ko, C. Y., & Esnaola, N. F. (2016) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2015.12.026 · Cited by 625
O’Grady, N. P., Barie, P. S., Bartlett, J. G., Bleck, T., Carroll, K., Kalil, A. C., Linden, P., Maki, D. G., Nierman, D., Pasculle, W., et al. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e318169eda9 · Cited by 600
Lefrant, J.-Y., Muller, L., de La Coussaye, J. E., Benbabaali, M., Lebris, C., Zeitoun, N., Mari, C., Saïssi, G., Ripart, J., & Eledjam, J.-J. (2003) · Intensive Care Medicine · doi:10.1007/s00134-002-1619-5 · Cited by 303
Hoedemaekers, C. W., Ezzahti, M., Gerritsen, A., & van der Hoeven, J. G. (2007) · Critical Care · doi:10.1186/cc6104 · Cited by 293
Fever after subarachnoid hemorrhage: Risk factors and impact on outcome
Fernandez, A., Schmidt, J. M., Claassen, J., Pavlicova, M., Huddleston, D., Kreiter, K. T., Ostapkovich, N. D., Kowalski, R. G., Parra, A., Connolly, E. S., et al. (2007) · Neurology · doi:10.1212/01.wnl.0000258543.45879.f5 · Cited by 262
Niven, D. J., Gaudet, J. E., Laupland, K. B., Mrklas, K. J., Roberts, D. J., & Stelfox, H. T. (2015) · Annals of Internal Medicine · doi:10.7326/m15-1150 · Cited by 240
Marik, P. E. (2000) · Chest · doi:10.1378/chest.117.3.855 · Cited by 195
Intrapartum Temperature Elevation, Epidural Use, and Adverse Outcome in Term Infants
Greenwell, E. A., Wyshak, G., Ringer, S. A., Johnson, L. C., Rivkin, M. J., & Lieberman, E. (2012) · Pediatrics · doi:10.1542/peds.2010-2301 · Cited by 179
Hooper, V. D., Chard, R., Clifford, T., Fetzer, S., Fossum, S., Godden, B., Martinez, E. A., Noble, K. A., O’Brien, D., Odom-Forren, J., et al. (2010) · Journal of PeriAnesthesia Nursing · doi:10.1016/j.jopan.2010.10.006 · Cited by 176
“Two studies have specifically examined tympanic variability.(80,81) Temporal artery measurements have been compared to oral,(74,76) and bladder.”
BackgroundCore Temperature Measurement—Principles of Correct Measurement, Problems, and Complications
Hymczak, H., Gołąb, A., Mendrala, K., Plicner, D., Darocha, T., Podsiadło, P., Hudziak, D., Gocoł, R., & Kosiński, S. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph182010606 · Cited by 161
“Twenty years ago, Moran and Mendal stated that, during this amazing era, we “forgot” to develop a better method for measuring body temperature [18,27].”
MethodResultThermometry in paediatric practice
El-Radhi, A. S. (2006) · Archives of Disease in Childhood · doi:10.1136/adc.2005.088831 · Cited by 160
Chen, H.-Y., Chen, A., & Chen, C. (2020) · Sensors · doi:10.3390/s20102885 · Cited by 139
“Erickson and Kirklin [27] performed invasive measurements using pulmonary artery temperature as an indicator to compare tympanic, bladder, oral and axillary temperature.”
BackgroundMethodTemporal and spatial dispersion of human body temperature during deep hypothermia
Opatz, O., Trippel, T., Lochner, A., Werner, A., Stahn, A., Steinach, M., Lenk, J., Kuppe, H., & Gunga, H. C. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aet217 · Cited by 22
Metadata
- Authors
- ERICKSON, R. S., & KIRKLIN, S. K.
- Venue
- Critical Care Medicine
- Published
- 1993-10
- Volume
- 21
- Issue
- 10
- Pages
- 1528-1534
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1973251111
- Cited by
- 189
- References
- 0
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.