CoChat

Comparison of propofol and midazolam for sedation in intensive care unit patients

Ronan, Kevin P., Gallagher, T. James, George, Beverly, Hamby, Brenda · 1995 · Critical Care Medicine
Cited by 173

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: To evaluate the comparative safety and effectiveness of intravenous infusion of propofol or midazolam when used for 12 to 24 hrs of sedation and to evaluate the quality of sedation during stimulation. DESIGN: An open, comparative, prospective, randomized study. SETTING: Surgical intensive care unit (ICU) in a university hospital. PATIENTS: Postoperative, intubated, general surgical, and orthopedic patients requiring mechanical ventilation (n = 60). INTERVENTIONS: None. MEASUREMENTS: Assessments were made at baseline (0 time), 5, 10, 15, 30, 45, and 60 mins; at 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, and 24 hrs; and at the end of sedation. The assessments included systolic, mean, and diastolic blood pressures, heart rate, two-lead electrocardiogram, pulse oximetry oxygen saturation, FIO2, end-tidal CO2, respiratory rate, ventilator rate, tidal volume, and sedation scale. Vital signs and the sedation scale were obtained at 30, 60, and 90 mins and at 2, 4, 12, and 24 hrs after the end of sedation. At approximately 8 hrs and 24 hrs (or at the end of sedation), the patient's CO2 production was calculated over a 5-min interval. Every 4 hrs, the nurse would summarize and rate patient response during stimulation as well as the overall rating of the sedation and patient ability to tolerate the ICU setting. MAIN RESULTS: There were no significant differences in pulse oximetry, arterial blood gas values, or respiratory measurements during sedation with propofol or midazolam. The mean heart rate was slower in the propofol group throughout the sedation and postsedation periods. The rating of sedation and tolerance of the ICU environment were significantly better for the propofol-treated group. Postsedation, the propofol group woke up faster on discontinuation of the sedative. CONCLUSIONS: Propofol was as safe and as efficacious as midazolam for continuous intravenous sedation. The quality of sedation was better in the propofol group.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199502000-00014

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 173

Metadata

Authors
Ronan, K. P., Gallagher, T. J., George, B., & Hamby, B.
Venue
Critical Care Medicine
Published
1995-02
Volume
23
Issue
2
Pages
286-293
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1999453458
Cited by
173
References
6
FWCI
11.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).