PRISM III: An updated Pediatric Risk of Mortality score
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: The relationship between physiologic status and mortality risk should be reevaluated as new treatment protocols, therapeutic interventions, and monitoring strategies are introduced and as patient populations change. We developed and validated a third-generation pediatric physiology-based score for mortality risk, Pediatric Risk of Mortality III (PRISM III). DESIGN: Prospective cohort. SETTING: There were 32 pediatric intensive care units (ICUs): 16 pediatric ICUs were randomly chosen and 16 volunteered. PATIENTS: Consecutive admissions at each site were included until at least 11 deaths per site occurred. MEASUREMENTS AND MAIN RESULTS: Physiologic data included the most abnormal values from the first 12 and the second 12 hrs of ICU stay. Outcomes and descriptive data were also collected. Physiologic variables where normal values change with age were stratified by age (neonate, infant, child, adolescent). The database was randomly split into development (90%) and validation (10%) sets. Variables and their ranges were chosen by computing the risk of death (odds ratios) relative to the midrange of survivors for each physiologic variable. Univariate and multivariate statistical procedures, including multiple logistic regression analysis, were used to develop the PRISM III score and mortality risk predictors. Data were collected on 11,165 admissions (543 deaths). The PRISM III score has 17 physiologic variables subdivided into 26 ranges. The variables most predictive of mortality were minimum systolic blood pressure, abnormal pupillary reflexes, and stupor/coma. Other risk factors, including two acute and two chronic diagnoses, and four additional risk factors, were used in the final predictors. The PRISM III score and the additional risk factors were applied to the first 12 hrs of stay (PRISM III-12) and the first 24 hours of stay (PRISM III-24). The Hosmer-Lemeshow chi-square goodness-of-fit evaluations demonstrated absence of significant calibration errors (p values: PRISM III-12 development = .2496; PRISM III-24 development = .1374; PRISM III-12 validation = .4168; PRISM III-24 validation = .5504). The area under the receiver operating curve and Flora's z-statistic indicated excellent discrimination and accuracy (area under the receiver operating curve - PRISM III-12 development 947 +/- 0.007; PRISM III-24 development 0.958 +/- 0.006; PRISM III-12 validation 0.941 +/- 0.021; PRISM III-24 validation 0.944 +/- 0.021; Flora's z-statistic - PRISM III-12 validation = .7479; PRISM III-24 validation = .9225), although generally, the PRISM III-24 performed better than the PRISM III-12 models. Excellent goodness-of-fit was also found for patient groups stratified by age (significance levels: PRISM III-12 = .1622; PRISM III-24 = .4137), and by diagnosis (significance levels: PRISM III-12 = .5992; PRISM III-24 = .7939). CONCLUSIONS: PRISM III resulted in several improvements over the original PRISM. Reassessment of physiologic variables and their ranges, better age adjustment for selected variables, and additional risk factors resulted in a mortality risk model that is more accurate and discriminates better. The large number of diverse ICUs in the database indicates PRISM III is more likely to be representative of United States units.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Gall, J.-R. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.270.24.2957 · Cited by 7,773
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
The APACHE III Prognostic System
Knaus, W. A., Wagner, D. P., Draper, E. A., Zimmerman, J. E., Bergner, M., Bastos, P. G., Sirio, C. A., Murphy, D. J., Lotring, T., Damiano, A., et al. (1991) · Chest · doi:10.1378/chest.100.6.1619 · Cited by 3,439
The APACHE III Prognostic System
Teres, D., & Lemeshow, S. (1992) · Chest · doi:10.1378/chest.102.6.1919b · Cited by 2,880
Pediatric risk of mortality (PRISM) score
POLLACK, M. M., RUTTIMANN, U. E., & GETSON, P. R. (1988) · Critical Care Medicine · doi:10.1097/00003246-198811000-00006 · Cited by 1,380
Self-citationLemeshow, S. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1993.03510200084037 · Cited by 1,029
The Performance of Intensive Care Units: Does Good Management Make a Difference?
Shortell, S. M., Zimmerman, J. E., Rousseau, D. M., Gillies, R. R., Wagner, D. P., Draper, E. A., Kanus, W. A., & Duffy, J. (1994) · Medical Care · doi:10.1097/00005650-199405000-00009 · Cited by 733
Score for Neonatal Acute Physiology: A Physiologic Severity Index for Neonatal Intensive Care
Richardson, D. K., Gray, J. E., McCormick, M. C., Workman, K., & Goldmann, D. A. (1993) · Pediatrics · doi:10.1542/peds.91.3.617 · Cited by 666
Variations in Mortality and Length of Stay in Intensive Care Units
Knaus, W. A., Wagner, D. P., Zimmerman, J. E., & Draper, E. A. (1993) · Annals of Internal Medicine · doi:10.7326/0003-4819-118-10-199305150-00001 · Cited by 545
Model Selection Via Multifold Cross Validation
Zhang, P. (1993) · The Annals of Statistics · doi:10.1214/aos/1176349027 · Cited by 539
Modeling the severity of illness of ICU patients. A systems update
Lemeshow, S. (1994) · JAMA · doi:10.1001/jama.272.13.1049 · Cited by 324
Modeling the severity of illness of ICU patients
Le Gall, J.-R. (2001) · European Journal of Internal Medicine · doi:10.1016/s0953-6205(01)00133-9 · Cited by 291
Impact of Quality-of-Care Factors on Pediatric Intensive Care Unit Mortality
Pollack, M. M. (1994) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1994.03520120051030 · Cited by 254
Self-citationShort-Rerm Mortality Predictions for Critically Ill Hospitalized Adults: Science and Ethics
Knaus, W. A., Wagner, D. P., & Lynn, J. (1991) · Science · doi:10.1126/science.1925596 · Cited by 232
Castella, X., Artigas, A., Bion, J., & Kari, A. (1995) · Critical Care Medicine · doi:10.1097/00003246-199508000-00005 · Cited by 196
RAPOPORT, J., TERES, D., LEMESHOW, S., & GEHLBACH, S. (1994) · Critical Care Medicine · doi:10.1097/00003246-199409000-00006 · Cited by 191
Accurate Prediction of the Outcome of Pediatric Intensive Care
Pollack, M. M., Ruttimann, U. E., Getson, P. R., & Members of the Multi-Institutional Study Group* (1987) · New England Journal of Medicine · doi:10.1056/nejm198701153160304 · Cited by 189
Self-citationTarnow‐Mordi, W., Ogston, S., Wilkinson, A. R., Reid, E., Gregory, J., Saeed, M., & Wilkie, R. (1990) · BMJ · doi:10.1136/bmj.300.6740.1611 · Cited by 96
Statistical Approaches to Development and Validation of Predictive Instruments
Ruttimann, U. E. (1994) · Critical Care Clinics · doi:10.1016/s0749-0704(18)30142-8 · Cited by 94
Self-citationPollack, M. M. (1987) · JAMA · doi:10.1001/jama.1987.03400110063026 · Cited by 82
Self-citationPollack, M. M., Patel, K. M., Ruttimann, U. E., & Cuerdon, T. T. (1996) · Critical Care Medicine · doi:10.1097/00003246-199601000-00013 · Cited by 47
Self-citation
Cited by
Physician Staffing Patterns and Clinical Outcomes in Critically Ill Patients: A Systematic Review
Pronovost, P. J., Angus, D. C., Dorman, T., Robinson, K. A., Dremsizov, T. T., & Young, T. L. (2002) · JAMA · doi:10.1001/jama.288.17.2151 · Cited by 1,506
Critically Ill Patients With 2009 Influenza A(H1N1) Infection in Canada
Kumar, A. (2009) · JAMA · doi:10.1001/jama.2009.1496 · Cited by 1,425
“Survivors 12 (5-22) [9-14]”
BackgroundConsensus-based method for risk adjustment for surgery for congenital heart disease
Jenkins, K. J., Gauvreau, K., Newburger, J. W., Spray, T. L., Moller, J. H., & Iezzoni, L. I. (2002) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2002.119064 · Cited by 1,368
SNAP-II and SNAPPE-II: Simplified newborn illness severity and mortality risk scores
Richardson, D. K., Corcoran, J. D., Escobar, G. J., & Lee, S. K. (2001) · The Journal of Pediatrics · doi:10.1067/mpd.2001.109608 · Cited by 1,157
PIM2: a revised version of the Paediatric Index of Mortality
for the PIM Study Group, Slater, A., Shann, F., & Pearson, G. (2003) · Intensive Care Medicine · doi:10.1007/s00134-002-1601-2 · Cited by 1,066
Metadata
- Authors
- Pollack, M. M., Patel, K. M., & Ruttimann, U. E.
- Venue
- Critical Care Medicine
- Published
- 1996-05
- Volume
- 24
- Issue
- 5
- Pages
- 743-752
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2084445380
- Cited by
- 1,759
- References
- 21
- FWCI
- 14.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.