The DOI matches its Crossref record.
A meta-analysis of three decades of validating thoracic impedance cardiography
Abstract
OBJECTIVE: To provide a meta-analysis of current literature concerning the validation of thoracic impedance cardiography (TIC) and to explain the variations in the reported results from the differences in the studies. DATA SOURCES: A computer-assisted search of English-language, German, and Dutch literature was performed for the period January 1966 to April 1997. Moreover, references from review articles were obtained. STUDY SELECTION: A total of 154 studies comparing measurements of cardiac output or related variables obtained from TIC and a reference method were analyzed. DATA EXTRACTION: Articles were classified by differences in TIC methodology, reference method, and subject characteristics. Fisher's Zf transformed correlation coefficients were used to compare results. Data were pooled using the random-effects method. DATA SYNTHESIS: An overall pooled r2 value of .67 (95% confidence interval, 0.64-0.71) was found. However, the correlation was higher in repeated-measurement designs than in single-measurement designs (r2 = .53; 95% confidence interval, 0.43-0.62). Further research using analysis of variance revealed a significant influence of the reference method and the subject characteristics on the correlation coefficient. The correlation was significantly better in animals than in cardiac patients. Subgroup analysis revealed that TIC correlated significantly better to the indirect Fick method than to echocardiography in healthy subjects. No significant influence of the applied TIC methodology was found. DISCUSSION: The overall r2 value of .67 indicates that TIC might be useful for trend analysis of different groups of patients. However, for diagnostic interpretation, a r2 value of .53 might not meet the required accuracy of the study. Great care should be taken when TIC is applied to the cardiac patient. However, because the applied reference method was of significant influence, differences between TIC and the reference method are incorrectly attributed to errors in TIC alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Westerhof, N., Lankhaar, J.-W., & Westerhof, B. E. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0359-2 · Cited by 1,181
Critchley, L. A., Lee, A., & Ho, A. M.-H. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181f08a5b · Cited by 512
Noninvasive Cardiac Output Monitors: A State-of the-Art Review
Marik, P. E. (2013) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2012.03.022 · Cited by 293
Noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine
Saugel, B., Cecconi, M., Wagner, J. Y., & Reuter, D. A. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aeu447 · Cited by 268
Autonomic Contribution to Blood Pressure and Metabolism in Obesity
Shibao, C., Gamboa, A., Diedrich, A., Ertl, A. C., Chen, K. Y., Byrne, D. W., Farley, G., Paranjape, S. Y., Davis, S. N., & Biaggioni, I. (2007) · Hypertension · doi:10.1161/01.hyp.0000251679.87348.05 · Cited by 147
Metadata
- Authors
- Raaijmakers, E., Faes, T. J. C., Scholten, R. J. P. M., Goovaerts, H. G., & Heethaar, R. M.
- Venue
- Critical Care Medicine
- Published
- 1999-06
- Volume
- 27
- Issue
- 6
- Pages
- 1203-1213
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1970933533
- Cited by
- 160
- References
- 0
- FWCI
- 0.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A meta-analysis of three decades of validating thoracic impedance cardiography. https://app.cochat.ai/papers/10.1097/00003246-199906000-00053
- The paper
- Raaijmakers, E., Faes, T. J. C., Scholten, R. J. P. M., Goovaerts, H. G., & Heethaar, R. M. (1999). A meta-analysis of three decades of validating thoracic impedance cardiography. Critical Care Medicine. https://doi.org/10.1097/00003246-199906000-00053
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.