A meta-analysis of three decades of validating thoracic impedance cardiography
The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To provide a meta-analysis of current literature concerning the validation of thoracic impedance cardiography (TIC) and to explain the variations in the reported results from the differences in the studies. DATA SOURCES: A computer-assisted search of English-language, German, and Dutch literature was performed for the period January 1966 to April 1997. Moreover, references from review articles were obtained. STUDY SELECTION: A total of 154 studies comparing measurements of cardiac output or related variables obtained from TIC and a reference method were analyzed. DATA EXTRACTION: Articles were classified by differences in TIC methodology, reference method, and subject characteristics. Fisher's Zf transformed correlation coefficients were used to compare results. Data were pooled using the random-effects method. DATA SYNTHESIS: An overall pooled r2 value of .67 (95% confidence interval, 0.64-0.71) was found. However, the correlation was higher in repeated-measurement designs than in single-measurement designs (r2 = .53; 95% confidence interval, 0.43-0.62). Further research using analysis of variance revealed a significant influence of the reference method and the subject characteristics on the correlation coefficient. The correlation was significantly better in animals than in cardiac patients. Subgroup analysis revealed that TIC correlated significantly better to the indirect Fick method than to echocardiography in healthy subjects. No significant influence of the applied TIC methodology was found. DISCUSSION: The overall r2 value of .67 indicates that TIC might be useful for trend analysis of different groups of patients. However, for diagnostic interpretation, a r2 value of .53 might not meet the required accuracy of the study. Great care should be taken when TIC is applied to the cardiac patient. However, because the applied reference method was of significant influence, differences between TIC and the reference method are incorrectly attributed to errors in TIC alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90318-p · Cited by 5,737
Methodological Guidelines for Impedance Cardiography
Sherwood(Chair), A., Allen, M. T., Fahrenberg, J., Kelsey, R. M., Lovallo, W. R., & van Doornen, L. J. P. (1990) · Psychophysiology · doi:10.1111/j.1469-8986.1990.tb02171.x · Cited by 1,169
A general parametric approach to the meta‐analysis of randomized clinical trials
Whitehead, A., & Whitehead, J. (1991) · Statistics in Medicine · doi:10.1002/sim.4780101105 · Cited by 750
A new stroke volume equation for thoracic electrical bioimpedance: Theory and rationale
BERNSTEIN, D. P. (1986) · Critical Care Medicine · doi:10.1097/00003246-198610000-00017 · Cited by 456
Hemodynamics of Blood Pressure Responses During Active and Passive Coping
Sherwood, A., Dolan, C. A., & Light, K. C. (1990) · Psychophysiology · doi:10.1111/j.1469-8986.1990.tb03189.x · Cited by 414
Work of breathing through different sized endotracheal tubes
SHAPIRO, M., Wilson, R. K., Casar, G., Bloom, K., & Teague, R. B. (1986) · Critical Care Medicine · doi:10.1097/00003246-198612000-00007 · Cited by 244
Statistics Notes: Correlation, regression, and repeated data
Bland, J. M., & Altman, D. G. (1994) · BMJ · doi:10.1136/bmj.308.6933.896 · Cited by 238
Measurement of cardiac output by electrical impedance at rest and during exercise
Denniston, J. C., Maher, J. T., Reeves, J. T., Cruz, J. C., Cymerman, A., & Grover, R. F. (1976) · Journal of Applied Physiology · doi:10.1152/jappl.1976.40.1.91 · Cited by 217
BERNSTEIN, D. P. (1986) · Critical Care Medicine · doi:10.1097/00003246-198610000-00015 · Cited by 212
Cited by
Westerhof, N., Lankhaar, J.-W., & Westerhof, B. E. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0359-2 · Cited by 1,181
Critchley, L. A., Lee, A., & Ho, A. M.-H. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181f08a5b · Cited by 512
Noninvasive Cardiac Output Monitors: A State-of the-Art Review
Marik, P. E. (2013) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2012.03.022 · Cited by 293
Noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine
Saugel, B., Cecconi, M., Wagner, J. Y., & Reuter, D. A. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aeu447 · Cited by 268
Minimally Invasive Cardiac Output Monitoring in the Perioperative Setting
Funk, D. J., Moretti, E. W., & Gan, T. J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31818ffd99 · Cited by 202
“53 when compared with a reference method which led the authors to conclude that the interpretation of CO values from TEB in cardiac patients should be undertaken with caution.(39) Unfortunately, this metaanalysis did not use the Bland–Altman approach to analyze their data.”
MethodHaemodynamic changes caused by oxytocin during caesarean section under spinal anaesthesia
Pinder, A. J., Dresner, M., Calow, C., Shorten, G. D., O'Riordan, J., & Johnson, R. (2002) · International Journal of Obstetric Anesthesia · doi:10.1054/ijoa.2002.0970 · Cited by 188
Stroke volume equation for impedance cardiography
Bernstein, D. P., & Lemmens, H. J. M. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344724 · Cited by 165
Noninvasive continuous hemodynamic monitoring
Truijen, J., van Lieshout, J. J., Wesselink, W. A., & Westerhof, B. E. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9375-8 · Cited by 161
“useful for trend analysis’’ [102].”
Autonomic Contribution to Blood Pressure and Metabolism in Obesity
Shibao, C., Gamboa, A., Diedrich, A., Ertl, A. C., Chen, K. Y., Byrne, D. W., Farley, G., Paranjape, S. Y., Davis, S. N., & Biaggioni, I. (2007) · Hypertension · doi:10.1161/01.hyp.0000251679.87348.05 · Cited by 147
Schmidlin, O., Forman Anthony Sebastian, A., & Morris, R. C. (2007) · Hypertension · doi:10.1161/hypertensionaha.106.084640 · Cited by 92
Antoniewicz, L., Novo, M., Bosson, J., & Lundbäck, M. (2018) · PLOS ONE · doi:10.1371/journal.pone.0195493 · Cited by 11
Effect of hemodialysis on impedance cardiography (electrical velocimetry) parameters in children
Wilken, M., Oh, J., Pinnschmidt, H. O., Singer, D., & Blohm, M. E. (2020) · Pediatric Nephrology · doi:10.1007/s00467-019-04409-1 · Cited by 8
Metadata
- Authors
- Raaijmakers, E., Faes, T. J. C., Scholten, R. J. P. M., Goovaerts, H. G., & Heethaar, R. M.
- Venue
- Critical Care Medicine
- Published
- 1999-06
- Volume
- 27
- Issue
- 6
- Pages
- 1203-1213
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1970933533
- Cited by
- 160
- References
- 66
- FWCI
- 0.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.