The DOI matches its Crossref record.
Sublingual capnometry: A new noninvasive measurement for diagnosis and quantitation of severity of circulatory shock
Abstract
OBJECTIVE: To investigate the feasibility and predictive value of sublingual Pco2 (P(SL)CO2) measurements as a noninvasive and early indicator of systemic perfusion failure. DESIGN: A prospective, criterion study. SETTING: Emergency department and medical and surgical intensive care units of an urban community medical center. PARTICIPANTS AND PATIENTS: Five normal human volunteers and 46 patients with acutely life-threatening illness or injuries. INTERVENTIONS: Intra-arterial or automated cuff blood pressure and arterial blood lactate (LAC) were measured concurrently with P(SL)CO2. RESULTS: P(SL)CO2 in five healthy volunteers was 45.2 +/- 0.7 mm Hg (mean +/- sD). Twenty-six patients with physical signs of circulatory shock and LAC >2.5 mmol/L had a P(SL)CO2 of 81 +/- 24 mm Hg. This contrasted with patients admitted without clinical signs of shock and LAC of <2.5 mmol/L who had a P(SL)CO2 of 53 +/- 8 mm Hg (p < .001). The initial P(SL)CO2 of 12 patients who died before recovery from shock was 93 +/- 27 mm Hg, and this contrasted with 58 +/- 11 mm Hg (p < .001) in hospital survivors. Increases in P(SL)CO2 were correlated with increases in LAC (r2 = .84; p < .001). When P(SL)CO2 exceeded a threshold of 70 mm Hg, its positive predictive value for the presence of physical signs of circulatory shock was 1.00. When it was <70 mm Hg, it predicted survival with a predictive value of 0.93. CONCLUSION: P(SL)CO2 may serve as a technically simple and noninvasive clinical measurement for the diagnosis and estimation of the severity of circulatory shock states.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microvascular Blood Flow Is Altered in Patients with Sepsis
De Backer, D., Creteur, J., Preiser, J.-C., Dubois, M.-J., & Vincent, J.-L. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200109-016oc · Cited by 1,473
Sakr, Y., Dubois, M.-J., De Backer, D., Creteur, J., & Vincent, J.-L. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000138558.16257.3f · Cited by 1,266
Trzeciak, S., Dellinger, R. P., Parrillo, J. E., Guglielmi, M., Bajaj, J., Abate, N. L., Arnold, R. C., Colilla, S., Zanotti, S., & Hollenberg, S. M. (2007) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.08.021 · Cited by 609
Practice parameters for hemodynamic support of sepsis in adult patients: 2004 update
Hollenberg, S. M., Ahrens, T. S., Annane, D., Astiz, M. E., Chalfin, D. B., Dasta, J. F., Heard, S. O., Martin, C., Napolitano, L. M., Susla, G. M., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000139761.05492.d6 · Cited by 521
Trzeciak, S., McCoy, J. V., Phillip Dellinger, R., Arnold, R. C., Rizzuto, M., Abate, N. L., Shapiro, N. I., Parrillo, J. E., Hollenberg, S. M., & on behalf of the Microcirculatory Alterations in Resuscitation and Shock (MARS) investigators (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1193-6 · Cited by 488
Metadata
- Authors
- Weil, M. H., Nakagawa, Y., Tang, W., Sato, Y., Ercoli, F., Finegan, R., Grayman, G., & Bisera, J.
- Venue
- Critical Care Medicine
- Published
- 1999-07
- Volume
- 27
- Issue
- 7
- Pages
- 1225-1229
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2093808610
- Cited by
- 233
- References
- 0
- FWCI
- 14.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sublingual capnometry: A new noninvasive measurement for diagnosis and quantitation of severity of circulatory shock. https://app.cochat.ai/papers/10.1097/00003246-199907000-00001
- The paper
- Weil, M. H., Nakagawa, Y., Tang, W., Sato, Y., Ercoli, F., Finegan, R., Grayman, G., & Bisera, J. (1999). Sublingual capnometry: A new noninvasive measurement for diagnosis and quantitation of severity of circulatory shock. Critical Care Medicine. https://doi.org/10.1097/00003246-199907000-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.