Enteral tube feeding in the intensive care unit: Factors impeding adequate delivery

McClave, Stephen A., Sexton, Leslie K., Spain, David A., Adams, Joyce L., Owens, Nancy A., Sullins, Mary Beth, Blandford, Barbara S., Snider, Harvy L.·1999·Critical Care Medicine

Abstract

OBJECTIVE: To evaluate those factors that impact on the delivery of enteral tube feeding. DESIGN: Prospective study. SETTING: Medical intensive care units (ICU) and coronary care units at two university-based hospitals. PATIENTS: Forty-four medical ICU/coronary care unit patients (mean age, 57.8 yrs; 70% male) who were to receive nothing by mouth and were placed on enteral tube feeding. INTERVENTIONS: Rate of enteral tube feeding ordered, actual volume delivered, patient position, residual volume, flush volume, presence of blue food coloring in oropharynx, and stool frequency were recorded every 4 hrs. Duration and reason for cessation of enteral tube feeding were documented. MEASUREMENTS AND MAIN RESULTS: Physicians ordered a daily mean volume of enteral tube feeding that was 65.6% of goal requirements, but an average of only 78.1% of the volume ordered was actually infused. Thus, patients received a mean volume of enteral tube feeding for all 339 days of infusion that was 51.6% of goal (range, 15.1% to 87.1%). Only 14% of patients reached > or = 90% of goal feeding (for a single day) within 72 hrs of the start of enteral tube feeding infusion. Of 24 patients weighed before and after, 54% were noted to lose weight on enteral tube feeding. Declining albumin levels through the enteral tube feeding period correlated significantly with decreasing percent of goal calories infused (p = .042; r2 = .13). Diarrhea occurred in 23 patients (52.3%) for a mean 38.2% of enteral tube feeding days. In >1490 bedside evaluations, patients were observed to be in the supine position only 0.45%, residual volume of >200 mL was found 2.8%, and blue food coloring was found in the oropharynx 5.1% of the time. Despite this, cessation of enteral tube feeding occurred in 83.7% of patients for a mean 19.6% of the potential infusion time. Sixty-six percent of the enteral tube feeding cessations was judged to be attributable to avoidable causes. CONCLUSIONS: The current manner in which enteral tube feeding is delivered in the ICU results in grossly inadequate nutritional support. Barely one half of patient caloric requirements are met because of underordering by physicians and reduced delivery through frequent and often inappropriate cessation of feedings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199907000-00003

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Research works printed but not linked: 6

  1. Zaloga, 1990, J Crit Illness, 5, 1180
  2. Charash, 1994, J Trauma, 37, 1015, 10.1097/00005373-199412000-00039 · doi:10.1097/00005373-199412000-00039
  3. Nishio, 1992, JPEN J Parenter Enteral Nutr, 16, 219, 10.1177/0148607192016003219 · doi:10.1177/0148607192016003219
  4. De la Torre, 1993, J Clin Invest, 92, 114, 10.1172/JCI116538 · doi:10.1172/jci116538
  5. Metheny, 1993, Heart Lung, 22, 213
  6. Scarr, 1989, Can Med Assoc J, 141, 1151

Cited by

See all 468

Metadata

Authors
McClave, S. A., Sexton, L. K., Spain, D. A., Adams, J. L., Owens, N. A., Sullins, M. B., Blandford, B. S., & Snider, H. L.
Venue
Critical Care Medicine
Published
1999-07
Volume
27
Issue
7
Pages
1252-1256
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2022856609
Cited by
468
References
16
FWCI
13.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Enteral tube feeding in the intensive care unit: Factors impeding adequate delivery. https://app.cochat.ai/papers/10.1097/00003246-199907000-00003
The paper
McClave, S. A., Sexton, L. K., Spain, D. A., Adams, J. L., Owens, N. A., Sullins, M. B., Blandford, B. S., & Snider, H. L. (1999). Enteral tube feeding in the intensive care unit: Factors impeding adequate delivery. Critical Care Medicine. https://doi.org/10.1097/00003246-199907000-00003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.