The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Positive end-expiratory pressure titration in acute respiratory distress syndrome patients: Impact on right ventricular outflow impedance evaluated by pulmonary artery Doppler flow velocity measurements
Abstract
OBJECTIVE: Positive end-expiratory pressure (PEEP) titration in acute respiratory distress syndrome patients remains debatable. We used two mechanical approaches, calculation of the compliance of the respiratory system and determination of the lower inflexion point of the pressure-volume curve of the respiratory system, to identify specific PEEPs (PEEPS and PEEPA) whose impact on right ventricular (RV) outflow was compared with Doppler analysis of pulmonary artery flow velocity. DESIGN: Prospective, open, clinical study. SETTING: Medical intensive care unit of a university hospital. PATIENTS: Sixteen consecutive ventilator-dependent acute respiratory distress syndrome patients. INTERVENTIONS: Two PEEPs were determined: PEEPS was the highest PEEP associated with the highest value of respiratory compliance, and PEEPA was the coordinate of the lower inflexion point of the inspiratory pressure-volume curve on the pressure axis plus 2 cm H2O. MEASUREMENTS AND MAIN RESULTS: We observed a large difference between the two PEEPs, with PEEPA (13 + 4 cm H2O) > PEEPS (6 + 3 cm H2O). Changes in RV outflow impedance produced by tidal ventilation with zero end-expiratory pressure (ZEEP) and after application of these two PEEPs were assessed by Doppler study of pulmonary artery flow velocity obtained by a transesophageal approach, with particular reference to the end-expiratory and end-inspiratory pulmonary artery velocity-time integral, as reflecting RV stroke output, and mean acceleration as reflecting RV outflow impedance during an unchanged flow period. A significant inspiratory reduction in pulmonary artery velocity-time integral (from 11.8 + 0.3 to 10.0 + 0.3 cm) and mean acceleration (from 11.9 + 0.9 to 8.0 + 0.9 m/sec2) was observed with ZEEP, showing a reduction in RV stroke index (from 29.0 + 0.9 to 26.0 + 0.6 cm3/m2) by a sudden increase in outflow impedance during tidal ventilation. Application of PEEPA, which improved Pao2 (102 + 40 vs. 65 + 18 torr with ZEEP), worsened the inspiratory drop in RV stroke index (21.6 + 0.8 cm3/m2), resulting in a significant reduction in cardiac index compared with ZEEP (from 3.0 + 1.0 to 2.7 + 1.1). Application of PEEPS, which also significantly improved Pao2 (81 + 21 torr), was associated with a lesser impact on RV outflow impedance (inspiratory mean acceleration: 9.5 + 1 m/sec2) and cardiac index (3.2 + 1.0) than PEEPA. CONCLUSION: RV outflow impedance evaluated by the Doppler technique appeared sensitive to PEEP titration. Application of PEEPA worsened RV systolic function impairment produced by tidal ventilation. Conversely, application of PEEPS reduced RV systolic function impairment, suggesting an association with a lower pulmonary vascular resistance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amato, M. B., Barbas, C. S., Medeiros, D. M., Schettino, G. D. P., Lorenzi Filho, G., Kairalla, R. A., Deheinzelin, D., Morais, C., Fernandes, E. D. O., & Takagaki, T. Y. (1995) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.152.6.8520744 · Cited by 625
Cited by
Formal guidelines: Management of acute respiratory distress syndrome.
Papazian, L., Aubron, C., Brochard, L., Chiche, J.-D., Combes, A., Dreyfuss, D., Forel, J.-M., Guérin, C., Jaber, S., Mekontso-Dessap, A., et al. (2019) · Annals of Intensive Care · doi:10.1186/s13613-019-0540-9 · Cited by 761
Self-citationMechanical Ventilation: State of the Art
Pham, T., Brochard, L. J., & Slutsky, A. S. (2017) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2017.05.004 · Cited by 377
Metadata
- Authors
- Schmitt, J.-M., Vieillard-Baron, A., Augarde, R., Prin, S., Page, B., & Jardin, F.
- Venue
- Critical Care Medicine
- Published
- 2001-06
- Volume
- 29
- Issue
- 6
- Pages
- 1154-1158
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1973897024
- Cited by
- 176
- References
- 1
- FWCI
- 4.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Positive end-expiratory pressure titration in acute respiratory distress syndrome patients: Impact on right ventricular outflow impedance evaluated by pulmonary artery Doppler flow velocity measurements. https://app.cochat.ai/papers/10.1097/00003246-200106000-00012
- The paper
- Schmitt, J.-M., Vieillard-Baron, A., Augarde, R., Prin, S., Page, B., & Jardin, F. (2001). Positive end-expiratory pressure titration in acute respiratory distress syndrome patients: Impact on right ventricular outflow impedance evaluated by pulmonary artery Doppler flow velocity measurements. Critical Care Medicine. https://doi.org/10.1097/00003246-200106000-00012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.