Positive end-expiratory pressure titration in acute respiratory distress syndrome patients: Impact on right ventricular outflow impedance evaluated by pulmonary artery Doppler flow velocity measurements
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Positive end-expiratory pressure (PEEP) titration in acute respiratory distress syndrome patients remains debatable. We used two mechanical approaches, calculation of the compliance of the respiratory system and determination of the lower inflexion point of the pressure-volume curve of the respiratory system, to identify specific PEEPs (PEEPS and PEEPA) whose impact on right ventricular (RV) outflow was compared with Doppler analysis of pulmonary artery flow velocity. DESIGN: Prospective, open, clinical study. SETTING: Medical intensive care unit of a university hospital. PATIENTS: Sixteen consecutive ventilator-dependent acute respiratory distress syndrome patients. INTERVENTIONS: Two PEEPs were determined: PEEPS was the highest PEEP associated with the highest value of respiratory compliance, and PEEPA was the coordinate of the lower inflexion point of the inspiratory pressure-volume curve on the pressure axis plus 2 cm H2O. MEASUREMENTS AND MAIN RESULTS: We observed a large difference between the two PEEPs, with PEEPA (13 + 4 cm H2O) > PEEPS (6 + 3 cm H2O). Changes in RV outflow impedance produced by tidal ventilation with zero end-expiratory pressure (ZEEP) and after application of these two PEEPs were assessed by Doppler study of pulmonary artery flow velocity obtained by a transesophageal approach, with particular reference to the end-expiratory and end-inspiratory pulmonary artery velocity-time integral, as reflecting RV stroke output, and mean acceleration as reflecting RV outflow impedance during an unchanged flow period. A significant inspiratory reduction in pulmonary artery velocity-time integral (from 11.8 + 0.3 to 10.0 + 0.3 cm) and mean acceleration (from 11.9 + 0.9 to 8.0 + 0.9 m/sec2) was observed with ZEEP, showing a reduction in RV stroke index (from 29.0 + 0.9 to 26.0 + 0.6 cm3/m2) by a sudden increase in outflow impedance during tidal ventilation. Application of PEEPA, which improved Pao2 (102 + 40 vs. 65 + 18 torr with ZEEP), worsened the inspiratory drop in RV stroke index (21.6 + 0.8 cm3/m2), resulting in a significant reduction in cardiac index compared with ZEEP (from 3.0 + 1.0 to 2.7 + 1.1). Application of PEEPS, which also significantly improved Pao2 (81 + 21 torr), was associated with a lesser impact on RV outflow impedance (inspiratory mean acceleration: 9.5 + 1 m/sec2) and cardiac index (3.2 + 1.0) than PEEPA. CONCLUSION: RV outflow impedance evaluated by the Doppler technique appeared sensitive to PEEP titration. Application of PEEPA worsened RV systolic function impairment produced by tidal ventilation. Conversely, application of PEEPS reduced RV systolic function impairment, suggesting an association with a lower pulmonary vascular resistance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ACUTE RESPIRATORY DISTRESS IN ADULTS
Ashbaugh, D., Boyd Bigelow, D., Petty, T., & Levine, B. (1967) · The Lancet · doi:10.1016/s0140-6736(67)90168-7 · Cited by 4,278
Optimum End-Expiratory Airway Pressure in Patients with Acute Pulmonary Failure
Suter, P. M., Fairley, H. B., & Isenberg, M. D. (1975) · New England Journal of Medicine · doi:10.1056/nejm197502062920604 · Cited by 1,295
Amato, M. B., Barbas, C. S., Medeiros, D. M., Schettino, G. D. P., Lorenzi Filho, G., Kairalla, R. A., Deheinzelin, D., Morais, C., Fernandes, E. D. O., & Takagaki, T. Y. (1995) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.152.6.8520744 · Cited by 625
The Pressure–Volume Curve Is Greatly Modified by Recruitment: A Mathematical Model of ARDS Lungs
HICKLING, K. G. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.1.9708049 · Cited by 412 · cited 2×
“An explanation is usually given, which is that the LIP is produced by the sudden opening of a “closed volume” and that the UIP is produced by a sudden increase in pressure when the total pulmonary volume is attained.”
BackgroundJONSON, B., RICHARD, J.-C., STRAUS, C., MANCEBO, J., LEMAIRE, F., & BROCHARD, L. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.4.9801088 · Cited by 385 · cited 6×
“In the present study, we have examined changes in RV outflow impedance at two specific PEEPs— PEEPS, determined by CRS measurements, as recommended 25 yrs ago by Suter (3), and PEEPA, determined by the LIP of the inspiratory (P/V) curve, as recommended more recently by Amato (4).”
BackgroundInfluentialCyclic changes in right ventricular output impedance during mechanical ventilation
Vieillard-Baron, A., Loubieres, Y., Schmitt, J.-M., Page, B., Dubourg, O., & Jardin, F. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.5.1644 · Cited by 303 · cited 2×
“Doppler demonstration of an inspiratory decrease in pulmonary artery Acmean, provided no change occurred in flow period at the same time, permitted detection of increased RV outflow impedance (7).”
BackgroundMethodSelf-citationA Simple Automated Method for Measuring Pressure–Volume Curves during Mechanical Ventilation
LU, Q., VIEIRA, S. R. R., RICHECOEUR, J., PUYBASSET, L., KALFON, P., CORIAT, P., & ROUBY, J.-J. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.1.9802082 · Cited by 169
Jardin, F., Genevray, B., BRUN-NEY, D., & Bourdarias, J. P. (1985) · CHEST Journal · doi:10.1378/chest.88.5.653 · Cited by 152 · cited 1×
“The increase in functional residual capacity produced by PEEP was measured as the difference between the first expiratory volumes when PEEP was abruptly removed and the preceding expiratory volume (8).”
BackgroundSelf-citationKoutsoukou, A., Armaganidis, A., STAVRAKAKI-KALLERGI, C., Vassilakopoulos, T., Lymberis, A., Roussos, C., & Milic‐Emili, J. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.5.9904109 · Cited by 117 · cited 4×
“These authors differentiated two major goals required for “optimal” airway pressure settings in ARDS: recruitment of atelectatic alveoli and prevention of cyclic reopening and closure of small airways (15).”
BackgroundResultInfluentialPulsed Wave Doppler Measurement of Cardiac Output from the Right Ventricular Outflow Tract
Maslow, A. D., Comunale, M. E., Haering, J. M., & Watkins, J. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199609000-00004 · Cited by 56 · cited 1×
“RV stroke output was calculated by multiplying pulmonary artery velocity-time integral (PAVTI) by cross-sectional area (10), and was expressed as stroke index after dividing by body surface area.”
Method
Cited by
Formal guidelines: Management of acute respiratory distress syndrome.
Papazian, L., Aubron, C., Brochard, L., Chiche, J.-D., Combes, A., Dreyfuss, D., Forel, J.-M., Guérin, C., Jaber, S., Mekontso-Dessap, A., et al. (2019) · Annals of Intensive Care · doi:10.1186/s13613-019-0540-9 · Cited by 761
Self-citationMatthay, M. A., & Zimmerman, G. A. (2005) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/rcmb.f305 · Cited by 642
Mekontso Dessap, A., Boissier, F., Charron, C., Bégot, E., Repessé, X., Legras, A., Brun-Buisson, C., Vignon, P., & Vieillard-Baron, A. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4141-2 · Cited by 550
Self-citationMechanical Ventilation: State of the Art
Pham, T., Brochard, L. J., & Slutsky, A. S. (2017) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2017.05.004 · Cited by 377
MALBOUISSON, L. M., MULLER, J.-C., CONSTANTIN, J.-M., LU, Q., PUYBASSET, L., ROUBY, J.-J., & the CT Scan ARDS Study Group (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.6.2005001 · Cited by 330
Metadata
- Authors
- Schmitt, J.-M., Vieillard-Baron, A., Augarde, R., Prin, S., Page, B., & Jardin, F.
- Venue
- Critical Care Medicine
- Published
- 2001-06
- Volume
- 29
- Issue
- 6
- Pages
- 1154-1158
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1973897024
- Cited by
- 176
- References
- 10
- FWCI
- 4.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.