The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Measurement of twitch transdiaphragmatic, esophageal, and endotracheal tube pressure with bilateral anterolateral magnetic phrenic nerve stimulation in patients in the intensive care unit
Abstract
OBJECTIVE: In the critically ill, respiratory muscle strength usually has been assessed by measuring maximum inspiratory pressure. The maneuver is volitional, and results can be unreliable. The nonvolitional technique of bilateral anterolateral magnetic stimulation of the phrenic nerves, producing twitch transdiaphragmatic pressure, has been successful in normal subjects and ambulatory patients. In this study we used the technique in the intensive care unit and explored the measurement of twitch endotracheal tube pressure as a less invasive technique to assess diaphragmatic contractility. DESIGN: Clinical study to quantify diaphragm strength in the intensive care unit. SETTING: Patients from three London teaching hospital intensive care units and high-dependency units. PATIENTS: Forty-one intensive care patients were recruited. Of these, 33 (20 men, 13 women) were studied. INTERVENTIONS: Esophageal and gastric balloon catheters were passed through the anaesthetized nose, and an endotracheal tube occlusion device was placed in the ventilation circuit, next to the endotracheal tube. Two 43-mm magnetic coils were placed anteriorly on the patient's neck, and the phrenic nerves were stimulated magnetically. MEASUREMENTS AND MAIN RESULTS: On phrenic nerve stimulation, twitch gastric pressure, twitch esophageal pressure, twitch transdiaphragmatic pressure, and twitch endotracheal tube pressure were measured. Forty-one consecutive patients consented to take part in the study, and twitch pressure data were obtained in 33 of these. Mean transdiaphragmatic pressure was 10.7 cm H2O, mean twitch esophageal pressure was 6.7 cm H2O, and mean twitch endotracheal tube pressure was 6.7 cm H2O. The mean difference between twitch esophageal pressure and twitch endotracheal tube pressure was 0.02 cm H2O. Correlation of the means of twitch endotracheal tube pressure to twitch esophageal pressure was 0.93, and that for twitch endotracheal tube pressure to transdiaphragmatic pressure was 0.78. CONCLUSIONS: Transdiaphragmatic pressure can be measured in the critically ill to give a nonvolitional assessment of diaphragm contractility, but not all patients can be studied. At present, the relationship of twitch endotracheal tube pressure to transdiaphragmatic pressure is too variable to reliably represent a less invasive measure of diaphragm strength.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Weaning from mechanical ventilation
Boles, J.-M., Bion, J., Connors, A., Herridge, M., Marsh, B., Melot, C., Pearl, R., Silverman, H., Stanchina, M., Vieillard-Baron, A., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00010206 · Cited by 2,064
Rapidly Progressive Diaphragmatic Weakness and Injury during Mechanical Ventilation in Humans
Jaber, S., Petrof, B. J., Jung, B., Chanques, G., Berthet, J.-P., Rabuel, C., Bouyabrine, H., Courouble, P., Koechlin-Ramonatxo, C., Sebbane, M., et al. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201004-0670oc · Cited by 709
Dres, M., Dubé, B.-P., Mayaux, J., Delemazure, J., Reuter, D., Brochard, L., Similowski, T., & Demoule, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201602-0367oc · Cited by 539
Ventilator-induced Diaphragmatic Dysfunction
Vassilakopoulos, T., & Petrof, B. J. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200304-489cp · Cited by 520
Demoule, A., Jung, B., Prodanovic, H., Molinari, N., Chanques, G., Coirault, C., Matecki, S., Duguet, A., Similowski, T., & Jaber, S. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201209-1668oc · Cited by 459
Metadata
- Authors
- Watson, A. C., Hughes, P. D., Louise Harris, M., Hart, N., Ware, R. J., Wendon, J., Green, M., & Moxham, J.
- Venue
- Critical Care Medicine
- Published
- 2001-07
- Volume
- 29
- Issue
- 7
- Pages
- 1325-1331
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2041704413
- Cited by
- 234
- References
- 1
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of twitch transdiaphragmatic, esophageal, and endotracheal tube pressure with bilateral anterolateral magnetic phrenic nerve stimulation in patients in the intensive care unit. https://app.cochat.ai/papers/10.1097/00003246-200107000-00005
- The paper
- Watson, A. C., Hughes, P. D., Louise Harris, M., Hart, N., Ware, R. J., Wendon, J., Green, M., & Moxham, J. (2001). Measurement of twitch transdiaphragmatic, esophageal, and endotracheal tube pressure with bilateral anterolateral magnetic phrenic nerve stimulation in patients in the intensive care unit. Critical Care Medicine. https://doi.org/10.1097/00003246-200107000-00005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.