Measurement of twitch transdiaphragmatic, esophageal, and endotracheal tube pressure with bilateral anterolateral magnetic phrenic nerve stimulation in patients in the intensive care unit
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: In the critically ill, respiratory muscle strength usually has been assessed by measuring maximum inspiratory pressure. The maneuver is volitional, and results can be unreliable. The nonvolitional technique of bilateral anterolateral magnetic stimulation of the phrenic nerves, producing twitch transdiaphragmatic pressure, has been successful in normal subjects and ambulatory patients. In this study we used the technique in the intensive care unit and explored the measurement of twitch endotracheal tube pressure as a less invasive technique to assess diaphragmatic contractility. DESIGN: Clinical study to quantify diaphragm strength in the intensive care unit. SETTING: Patients from three London teaching hospital intensive care units and high-dependency units. PATIENTS: Forty-one intensive care patients were recruited. Of these, 33 (20 men, 13 women) were studied. INTERVENTIONS: Esophageal and gastric balloon catheters were passed through the anaesthetized nose, and an endotracheal tube occlusion device was placed in the ventilation circuit, next to the endotracheal tube. Two 43-mm magnetic coils were placed anteriorly on the patient's neck, and the phrenic nerves were stimulated magnetically. MEASUREMENTS AND MAIN RESULTS: On phrenic nerve stimulation, twitch gastric pressure, twitch esophageal pressure, twitch transdiaphragmatic pressure, and twitch endotracheal tube pressure were measured. Forty-one consecutive patients consented to take part in the study, and twitch pressure data were obtained in 33 of these. Mean transdiaphragmatic pressure was 10.7 cm H2O, mean twitch esophageal pressure was 6.7 cm H2O, and mean twitch endotracheal tube pressure was 6.7 cm H2O. The mean difference between twitch esophageal pressure and twitch endotracheal tube pressure was 0.02 cm H2O. Correlation of the means of twitch endotracheal tube pressure to twitch esophageal pressure was 0.93, and that for twitch endotracheal tube pressure to transdiaphragmatic pressure was 0.78. CONCLUSIONS: Transdiaphragmatic pressure can be measured in the critically ill to give a nonvolitional assessment of diaphragm contractility, but not all patients can be studied. At present, the relationship of twitch endotracheal tube pressure to transdiaphragmatic pressure is too variable to reliably represent a less invasive measure of diaphragm strength.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Yang, K. L., & Tobin, M. J. (1991) · New England Journal of Medicine · doi:10.1056/nejm199105233242101 · Cited by 1,378
Peripheral Nerve Function in Sepsis and Multiple Organ Failure
Witt, N. J., Zochodne, D. W., Bolton, C. F., Grand'Maison, F., Wells, G., Young, G. B., & Sibbald, W. J. (1991) · Chest · doi:10.1378/chest.99.1.176 · Cited by 577 · cited 1×
“It has been estimated that some 70% of patients with sepsis and multiple organ failure develop critical illness neuromuscular abnormalities (1), which can lead to difficulty in weaning from mechanical ventilation (2) and prolonged intensive care unit (ICU) stay.”
BackgroundSimilowski, T., Fleury, B., Launois, S., Cathala, H. P., Bouche, P., & Derenne, J. P. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.67.4.1311 · Cited by 324
Diaphragm strength in chronic obstructive pulmonary disease.
Polkey, M. I., Kyroussis, D., Hamnegard, C. H., Mills, G. H., Green, M., & Moxham, J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.5.8912741 · Cited by 266 · cited 1×
“(23) observed similar partitioning in normal subjects, with TwPes/ TwPdi being 0.”
BackgroundSelf-citationMarini, J. J., Smith, T. C., & Lamb, V. (1986) · Journal of Critical Care · doi:10.1016/s0883-9441(86)80114-9 · Cited by 244 · cited 1×
“(5), and it is applicable to patients who are capable of some respiratory effort but who may be uncooperative or sedated.”
BackgroundRanieri, V. M., Giuliani, R., Cinnella, G., Pesce, C., Brienza, N., Lippolito, E., Pomo, V., Fiore, T., Gottfried, S. B., & Brienza, A. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.1.5 · Cited by 235 · cited 11×
“In most patients, this does not represent a problem, but for patients dependent on high levels of PEEP, even a brief loss of pressure could be detrimental.”
BackgroundInfluentialAnzueto, A., Peters, J. I., Tobin, M. J., De Los Santos, R., Seidenfeld, J. J., Moore, G., Cox, W. J., & Coalson, J. J. (1997) · Critical Care Medicine · doi:10.1097/00003246-199707000-00021 · Cited by 196 · cited 1×
“(13), malnutrition (14, 15), metabolic derangement (16, 17), the effects of specific drugs (18, 19), and the effects of severe,”
BackgroundBilateral magnetic stimulation of the phrenic nerves from an anterolateral approach.
Mills, G. H., Kyroussis, D., Hamnegard, C. H., Polkey, M. I., Green, M., & Moxham, J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.4.8887614 · Cited by 183 · cited 11×
“Phrenic nerve stimulation was achieved with two 43-mm magnetic coils (Magstim, Dyfed, Wales) placed firmly anterolaterally on either side of the neck, lateral to the cricoid cartilage (9).”
BackgroundMethodResultSelf-citation
Cited by
Weaning from mechanical ventilation
Boles, J.-M., Bion, J., Connors, A., Herridge, M., Marsh, B., Melot, C., Pearl, R., Silverman, H., Stanchina, M., Vieillard-Baron, A., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00010206 · Cited by 2,064
Rapidly Progressive Diaphragmatic Weakness and Injury during Mechanical Ventilation in Humans
Jaber, S., Petrof, B. J., Jung, B., Chanques, G., Berthet, J.-P., Rabuel, C., Bouyabrine, H., Courouble, P., Koechlin-Ramonatxo, C., Sebbane, M., et al. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201004-0670oc · Cited by 709
Dres, M., Dubé, B.-P., Mayaux, J., Delemazure, J., Reuter, D., Brochard, L., Similowski, T., & Demoule, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201602-0367oc · Cited by 539
Ventilator-induced Diaphragmatic Dysfunction
Vassilakopoulos, T., & Petrof, B. J. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200304-489cp · Cited by 520
Demoule, A., Jung, B., Prodanovic, H., Molinari, N., Chanques, G., Coirault, C., Matecki, S., Duguet, A., Similowski, T., & Jaber, S. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201209-1668oc · Cited by 459
Critical illness-associated diaphragm weakness
Dres, M., Goligher, E. C., Heunks, L. M. A., & Brochard, L. J. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4928-4 · Cited by 402
The Sick and the Weak: Neuropathies/Myopathies in the Critically Ill
Friedrich, O., Reid, M. B., Van den Berghe, G., Vanhorebeek, I., Hermans, G., Rich, M. M., & Larsson, L. (2015) · Physiological Reviews · doi:10.1152/physrev.00028.2014 · Cited by 396
Jung, B., Moury, P. H., Mahul, M., de Jong, A., Galia, F., Prades, A., Albaladejo, P., Chanques, G., Molinari, N., & Jaber, S. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4125-2 · Cited by 330
Callahan, L. A., & Supinski, G. S. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181b6e439 · Cited by 298
Hermans, G., Agten, A., Testelmans, D., Decramer, M., & Gayan-Ramirez, G. (2010) · Critical Care · doi:10.1186/cc9094 · Cited by 274
Diaphragm weakness in mechanically ventilated critically ill patients
Supinski, G. S., & Ann Callahan, L. (2013) · Critical Care · doi:10.1186/cc12792 · Cited by 265
Mechanical Ventilation–induced Diaphragm Disuse in Humans Triggers Autophagy
Hussain, S. N. A., Mofarrahi, M., Sigala, I., Kim, H. C., Vassilakopoulos, T., Maltais, F., Bellenis, I., Chaturvedi, R., Gottfried, S. B., Metrakos, P., et al. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201002-0234oc · Cited by 264
Scope and epidemiology of pediatric sepsis
Watson, R. S., & Carcillo, J. A. (2005) · Pediatric Critical Care Medicine · doi:10.1097/01.pcc.0000161289.22464.c3 · Cited by 250
Ricoy, J., Rodríguez-Núñez, N., Álvarez-Dobaño, J. M., Toubes, M. E., Riveiro, V., & Valdés, L. (2019) · Pulmonology · doi:10.1016/j.pulmoe.2018.10.008 · Cited by 228
Dubé, B.-P., Dres, M., Mayaux, J., Demiri, S., Similowski, T., & Demoule, A. (2017) · Thorax · doi:10.1136/thoraxjnl-2016-209459 · Cited by 216
“Diaphragm dysfunction has become a leading concern in mechanically ventilated patients because of its high prevalence 1 – 4 and its association with negative clinical outcomes.”
BackgroundDiaphragm Dysfunction in Critical Illness
Supinski, G. S., Morris, P. E., Dhar, S., & Callahan, L. A. (2018) · Chest · doi:10.1016/j.chest.2017.08.1157 · Cited by 211
Jaber, S., Jung, B., Matecki, S., & Petrof, B. J. (2011) · Critical Care · doi:10.1186/cc10023 · Cited by 195
Ventilator-induced diaphragmatic dysfunction
Petrof, B. J., Jaber, S., & Matecki, S. (2010) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e328334b166 · Cited by 179
Spadaro, S., Grasso, S., Mauri, T., Dalla Corte, F., Alvisi, V., Ragazzi, R., Cricca, V., Biondi, G., Di Mussi, R., Marangoni, E., et al. (2016) · Critical Care · doi:10.1186/s13054-016-1479-y · Cited by 163
“Direct evaluation of diaphragmatic strength is based on the measurement of the maximal trans-diaphragmatic pressure generated by the diaphragm during phrenic nerve stimulation (twitch-occlusion technique) or of the diaphragmatic tension-time index [13, 14].”
MethodMan, W. D.-C. (2003) · Thorax · doi:10.1136/thorax.58.8.665 · Cited by 160
“Even in the challenging ICU setting we have shown that BAMPS was supramaximal in 23 of 25 patients”
MethodEicosapentaenoic acid preserves diaphragm force generation following endotoxin administration
Supinski, G. S., Vanags, J., & Callahan, L. A. (2010) · Critical Care · doi:10.1186/cc8913 · Cited by 43
Lozano-García, M., Sarlabous, L., Moxham, J., Rafferty, G. F., Torres, A., Jané, R., & Jolley, C. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-35024-z · Cited by 32
Self-citation
Metadata
- Authors
- Watson, A. C., Hughes, P. D., Louise Harris, M., Hart, N., Ware, R. J., Wendon, J., Green, M., & Moxham, J.
- Venue
- Critical Care Medicine
- Published
- 2001-07
- Volume
- 29
- Issue
- 7
- Pages
- 1325-1331
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2041704413
- Cited by
- 234
- References
- 21
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.