Prospective trial of high-frequency oscillation in adults with acute respiratory distress syndrome
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate the safety and efficacy of high-frequency oscillatory ventilation (HFOV) in adult patients with the acute respiratory distress syndrome (ARDS) and oxygenation failure. DESIGN: Prospective, clinical study. SETTING: Intensive care and burn units of two university teaching hospitals. PATIENTS: Twenty-four adults (10 females, 14 males, aged 48.5 +/- 15.2 yrs, Acute Physiology and Chronic Health Evaluation II score 21.5 +/- 6.9) with ARDS (lung injury score 3.4 +/- 0.6, Pao2/Fio2 98.8 +/- 39.0 mm Hg, and oxygenation index 32.5 +/- 19.6) who met one of the following criteria: Pao2 < or =65 mm Hg with Fio2 > or =0.6, or plateau pressure > or =35 cm H2O. INTERVENTIONS: HFOV was initiated in patients with ARDS after varying periods of conventional ventilation (CV). Mean airway pressure (Paw) was initially set 5 cm H2O greater than Paw during CV, and was subsequently titrated to maintain oxygen saturation between 88% and 93% and Fio2 < or =0.60. MEASUREMENTS AND MAIN RESULTS: Fio2, Paw, pressure amplitude of oscillation, frequency, blood pressure, heart rate, and arterial blood gases were monitored during the transition from CV to HFOV, and every 8 hrs thereafter for 72 hrs. In 16 patients who had pulmonary artery catheters in place, cardiac hemodynamics were recorded at the same time intervals. Throughout the HFOV trial, Paw was significantly higher than that applied during CV. Within 8 hrs of HFOV application, and for the duration of the trial, Fio2 and Paco2 were lower, and Pao2/Fio2 was higher than baseline values during CV. Significant changes in hemodynamic variables following HFOV initiation included an increase in pulmonary artery occlusion pressure (at 8 and 40 hrs) and central venous pressure (at 16 and 40 hrs), and a reduction in cardiac output throughout the course of the study. There were no significant changes in systemic or pulmonary pressure associated with initiation and maintenance of HFOV. Complications occurring during HFOV included pneumothorax in two patients and desiccation of secretions in one patient. Survival at 30 days was 33%, with survivors having been mechanically ventilated for fewer days before institution of HFOV compared with nonsurvivors (1.6 +/- 1.2 vs. 7.8 +/- 5.8 days; p =.001). CONCLUSIONS: These findings suggest that HFOV has beneficial effects on oxygenation and ventilation, and may be a safe and effective rescue therapy for patients with severe oxygenation failure. In addition, early institution of HFOV may be advantageous.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
APACHE II: A severity of disease classification system
KNAUS, W. A., DRAPER, E. A., WAGNER, D. P., & ZIMMERMAN, J. E. (1985) · Critical Care Medicine · doi:10.1097/00003246-198510000-00009 · Cited by 13,664
APACHE II-A Severity of Disease Classification System: Reply
Knaus, W. A., Draper, E. A., Wagner, D. P., & Zimmerman, J. E. (1986) · Critical Care Medicine · doi:10.1097/00003246-198608000-00028 · Cited by 13,376
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Random-Effects Models for Longitudinal Data
Laird, N. M., & Ware, J. H. (1982) · Biometrics · doi:10.2307/2529876 · Cited by 8,923 · cited 1×
“Mixed model repeated measures analyses (31) were used to determine whether PaO2/FIO2 ratio, PaCO2, OI, FIO2, and Paw were significantly different at initiation of HFOV, and 8 – 48 hrs after HFOV compared with CV.”
MethodBernard, G. R., Artigas, A., Brigham, K. L., Carlet, J., Falke, K., Hudson, L., Lamy, M., Legall, J. R., Morris, A., & Spragg, R. (1994) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.149.3.7509706 · Cited by 6,746
Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome.
Amato, M. B. P., Barbas, C. S. V., Medeiros, D. M., Magaldi, R. B., Schettino, G. P., Lorenzi-Filho, G., Kairalla, R. A., Deheinzelin, D., Munoz, C., Oliveira, R., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380602 · Cited by 3,654 · cited 1×
“(10, 11) also demonstrated benefits in gas exchange, lung recovery, and weaning rate using a lung-protective ventilation strategy consisting of positive end-expiratory pressure greater than the lower inflection point, tidal volume ,6 mL/kg (with permissive hypercapnia), volume recruitment maneuvers, and peak inspirato…”
BackgroundAn Expanded Definition of the Adult Respiratory Distress Syndrome
Murray, J. F., Matthay, M. A., Luce, J. M., & Flick, M. R. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/138.3.720 · Cited by 2,646
Ranieri, V. M., Suter, P. M., Tortorella, C., De Tullio, R., Dayer, J. M., Brienza, A., Bruno, F., & Slutsky, A. S. (1999) · JAMA · doi:10.1001/jama.282.1.54 · Cited by 1,908
Dreyfuss, D., Soler, P., Basset, G., & Saumon, G. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/137.5.1159 · Cited by 1,717
Tremblay, L., Valenza, F., Ribeiro, S. P., Li, J., & Slutsky, A. S. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119259 · Cited by 1,330
Cited by
Acute lung injury and the acute respiratory distress syndrome: a clinical review
Wheeler, A. P., & Bernard, G. R. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60604-7 · Cited by 904
High-Frequency Oscillation in Early Acute Respiratory Distress Syndrome
Ferguson, N. D., Cook, D. J., Guyatt, G. H., Mehta, S., Hand, L., Austin, P., Zhou, Q., Matte, A., Walter, S. D., Lamontagne, F., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1215554 · Cited by 874
Self-citationHigh-Frequency Oscillation for Acute Respiratory Distress Syndrome
Young, D., Lamb, S. E., Shah, S., MacKenzie, I., Tunnicliffe, W., Lall, R., Rowan, K., & Cuthbertson, B. H. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1215716 · Cited by 652
Derdak, S., Mehta, S., Stewart, T. E., Smith, T., Rogers, M., Buchman, T. G., Carlin, B., Lowson, S., Granton, J., & Respirator, T. M. O. V. F. A. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2108052 · Cited by 624
Self-citationMowery, N. T., Terzian, W. T. H., & Nelson, A. C. (2020) · Current Problems in Surgery · doi:10.1016/j.cpsurg.2020.100777 · Cited by 314
Bollen, C. W., van Well, G. T. J., Sherry, T., Beale, R. J., Shah, S., Findlay, G., Monchi, M., Chiche, J.-D., Weiler, N., Uiterwaal, C. S., et al. (2005) · Critical Care · doi:10.1186/cc3737 · Cited by 249
“Three non-randomized prospective trials and no more than two randomized controlled trials in patients with ARDS have been published to establish the safety and efficacy of HFOV [7-11].”
BackgroundSud, S., Sud, M., Friedrich, J. O., Meade, M. O., Ferguson, N. D., Wunsch, H., & Adhikari, N. K. J. (2010) · BMJ · doi:10.1136/bmj.c2327 · Cited by 246
“Several observational studies have shown improved oxygenation in patients with refractory hypoxaemia.”
BackgroundHigh-frequency oscillatory ventilation in adult acute respiratory distress syndrome
David, M., Weiler, N., Heinrichs, W., Neumann, M., Joost, T., Markstaller, K., & Eberle, B. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1897-6 · Cited by 226
“[13] treated 24 ARDS patients with HFOV”
BackgroundInfluentialHigh-frequency oscillatory ventilation for acute respiratory distress syndrome in adult patients
Derdak, S. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000057910.50618.eb · Cited by 222
“(27) nonrandomized studies, a prolonged period receiving CV (i.”
BackgroundLow-Tidal-Volume Ventilation in the Acute Respiratory Distress Syndrome
Malhotra, A. (2007) · New England Journal of Medicine · doi:10.1056/nejmct074213 · Cited by 217
Acute respiratory distress syndrome: new definition, current and future therapeutic options.
Fanelli, V., Vlachou, A., Ghannadian, S., Simonetti, U., Slutsky, A. S., & Zhang, H. (2013) · PubMed · doi:10.3978/j.issn.2072-1439.2013.04.05 · Cited by 215
Peek, G., Elbourne, D., Mugford, M., Tiruvoipati, R., Wilson, A., Allen, E., Clemens, F., Firmin, R., Hardy, P., Hibbert, C., et al. (2010) · Health Technology Assessment · doi:10.3310/hta14350 · Cited by 191
Severe Hypoxemic Respiratory Failure
Raoof, S., Goulet, K., Esan, A., Hess, D. R., & Sessler, C. N. (2010) · Chest · doi:10.1378/chest.09-2416 · Cited by 181
Primary Pulmonary Sporotrichosis: A Case Report
Mehta, A., Budev, M. M., Ranes, J., & Shrestha, R. (2004) · Chest · doi:10.1378/chest.126.2.518 · Cited by 167
Therapies for refractory hypoxemia in acute respiratory distress syndrome
Pipeling, M. R., & Fan, E. (2010) · JAMA · doi:10.1001/jama.2010.1752 · Cited by 126
Metadata
- Authors
- Mehta, S., Lapinsky, S. E., Hallett, D. C., Merker, D., Groll, R. J., Cooper, A. B., MacDonald, R. J., & Stewart, T. E.
- Venue
- Critical Care Medicine
- Published
- 2001-07
- Volume
- 29
- Issue
- 7
- Pages
- 1360-1369
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2155849305
- Cited by
- 263
- References
- 26
- FWCI
- 16.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.