Delayed gastric emptying in ventilated critically ill patients: Measurement by 13C-octanoic acid breath test
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To measure gastric emptying in ventilated critically ill patients with a new noninvasive breath test. DESIGN: Single-center, open study. SETTING: Combined medical and surgical intensive care unit of a university hospital. SUBJECTS: Thirty unselected mechanically ventilated critically ill patients receiving gastric feeding and 22 healthy volunteers. INTERVENTIONS: None. PATIENTS: After 4 hrs without feeding, intragastric infusion of 100 mL of a liquid meal (Ensure) labeled with 100 microL 13C-octanoic acid. End-expiratory breath samples were collected into evacuated tubes from the respirator circuit every 5 mins for the first hour, then every 15 mins for 3 hrs. End-expiratory breath samples were also collected from volunteers studied supine after an overnight fast following an identical infusion via a nasogastric tube. Breath 13CO2 was measured with an isotope ratio mass spectrometer. MEASUREMENTS AND MAIN RESULTS: Performance of the breath test posed no difficulty or interference with patient care. The CO2 level was >1% in 1297/1300 breath samples, indicating satisfactory end-expiratory timing. Data are median and interquartile range. Gastric emptying was slower in patients compared with volunteers: gastric emptying coefficient 2.93 (2.17-3.39) vs. 3.58 (3.18-3.79), p <.001 and gastric half emptying time, derived from the area under the 13CO2 curve, 155 min (130-220) vs. 133 min (120-145), p <.008. Fourteen of the 30 patients had a gastric emptying coefficient <95% of all volunteers and 11 had a gastric half emptying time longer than 95% of all volunteers. The Acute Physiology and Chronic Health Evaluation (APACHE II) score (median 22, range 13-43) either at admission or on the day of the study did not correlate with gastric emptying coefficient. CONCLUSION: Gastric emptying of a calorie-dense liquid meal is slow in 40% to 45% of unselected mechanically ventilated patients in a combined medical and surgical intensive care unit. The 13C-octanoic acid breath test is a novel and useful bedside technique to measure gastric emptying in these patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Barr, J., Hecht, M., Flavin, K. E., Khorana, A., & Gould, M. K. (2004) · Chest · doi:10.1378/chest.125.4.1446 · Cited by 415
Deane, A. M., Chapman, M. J., Fraser, R. J. L., Summers, M. J., Zaknic, A. V., Storey, J. P., Jones, K. L., Rayner, C. K., & Horowitz, M. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181d9d87a · Cited by 104
Self-citationWhite, H., Sosnowski, K., Tran, K., Reeves, A., & Jones, M. (2009) · Critical Care · doi:10.1186/cc8181 · Cited by 103
Gutierrez, A., Carlson, C., Kalra, R., Elliott, A. M., Yannopoulos, D., & Bartos, J. A. (2021) · Resuscitation · doi:10.1016/j.resuscitation.2021.04.029 · Cited by 30
Metadata
- Authors
- Ritz, M. A., Fraser, R., Edwards, N., Di Matteo, A. C., Chapman, M., Butler, R., Cmielewski, P., Tournadre, J.-P., Davidson, G., & Dent, J.
- Venue
- Critical Care Medicine
- Published
- 2001-09
- Volume
- 29
- Issue
- 9
- Pages
- 1744-1749
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2045064077
- Cited by
- 138
- References
- 0
- FWCI
- 4.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Delayed gastric emptying in ventilated critically ill patients: Measurement by 13C-octanoic acid breath test. https://app.cochat.ai/papers/10.1097/00003246-200109000-00015
- The paper
- Ritz, M. A., Fraser, R., Edwards, N., Di Matteo, A. C., Chapman, M., Butler, R., Cmielewski, P., Tournadre, J.-P., Davidson, G., & Dent, J. (2001). Delayed gastric emptying in ventilated critically ill patients: Measurement by 13C-octanoic acid breath test. Critical Care Medicine. https://doi.org/10.1097/00003246-200109000-00015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.