Estimation of end-expiratory lung volume variations by optoelectronic plethysmography
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To test the capability of optoelectronic plethysmography (OEP) to monitor positive end-expiratory pressure (PEEP)-induced changes of end-expiratory lung volume (EELV) changes in mechanically ventilated paralyzed patients. DESIGN: Laboratory and clinical investigation. SETTING: Intensive care unit of the Ospedale Maggiore Policlinico di Milano. PATIENTS: A total of eight patients with respiratory failure of various degrees, sedated and paralyzed. INTERVENTIONS: PEEP variations (+/-5 cm H2O) relative to the baseline PEEP of 10 cm H2O. MEASUREMENTS AND MAIN RESULTS: In the model protocol, we tested the reproducibility of the OEP by repeating volume measurements of a plastic torso model over a 21-hr period, every 30 mins. The variations of OEP measurements of the torso model (9337 mL value) were encountered in a range of 16 mL (sd = 4 mL). In the patient protocol, we measured the end-expiratory volume of the chest wall (EEVCW) breath-by-breath by OEP before, during, and after the PEEP increase/decrease and we compared its variations with the corresponding variations of EELV measured by helium dilution technique. The regression line between EELV changes measured by helium and EEVCW changes measured by OEP resulted very close to the identity line (slope 1.06, intercept -0.02 L, r(2) = 0.89) and their difference was not related to their absolute magnitude. After PEEP increase, the new steady state of EEVCW was reached approximately in 15 breaths; and, after PEEP decrease, in 3-4 breaths. The slow increase in EEVCW was mainly because of the abdominal compartment. CONCLUSION: OEP measurements of EEVCW accurately reflect the changes of EELV. Furthermore, OEP allows a continuous compartmental analysis, even during unsteady conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Flow limitation and dynamic hyperinflation: key concepts in modern respiratory physiology
Calverley, P. M. A., & Koulouris, N. G. (2005) · European Respiratory Journal · doi:10.1183/09031936.04.00113204 · Cited by 258
Regional chest wall volumes during exercise in chronic obstructive pulmonary disease
Aliverti, A. (2004) · Thorax · doi:10.1136/thorax.2003.011494 · Cited by 226
Self-citationSmart textile for respiratory monitoring and thoraco-abdominal motion pattern evaluation
Massaroni, C., Venanzi, C., Silvatti, A. P., Lo Presti, D., Saccomandi, P., Formica, D., Giurazza, F., Caponero, M. A., & Schena, E. (2018) · Journal of Biophotonics · doi:10.1002/jbio.201700263 · Cited by 139
Metadata
- Authors
- Dellacà, R. L., Aliverti, A., Pelosi, P., Carlesso, E., Chiumello, D., Pedotti, A., & Gattinoni, L.
- Venue
- Critical Care Medicine
- Published
- 2001-09
- Volume
- 29
- Issue
- 9
- Pages
- 1807-1811
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2323641416
- Cited by
- 55
- References
- 1
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimation of end-expiratory lung volume variations by optoelectronic plethysmography. https://app.cochat.ai/papers/10.1097/00003246-200109000-00026
- The paper
- Dellacà, R. L., Aliverti, A., Pelosi, P., Carlesso, E., Chiumello, D., Pedotti, A., & Gattinoni, L. (2001). Estimation of end-expiratory lung volume variations by optoelectronic plethysmography. Critical Care Medicine. https://doi.org/10.1097/00003246-200109000-00026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.