The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
How reliable is the Bispectral Index in critically ill patients? A prospective, comparative, single-blinded observer study*
Abstract
OBJECTIVE: To establish a correlation between a reliable subjective measure, the Sedation-Agitation Scale (SAS), and an objective tool, the Bispectral Index (BIS), for monitoring critically ill patients with a decreased level of consciousness. DESIGN: Prospective, comparative, single-blinded observer study. SETTING: Surgical and medical intensive care units of the Tufts-New England Medical Center, a 349-bed tertiary care, academic medical center. PATIENTS: A convenience sample of 20 adult, critically ill patients with a decreased level of consciousness. The data from one patient were excluded because the patient did not meet inclusion criteria. MEASUREMENTS AND MAIN RESULTS: Patients were prospectively evaluated by a blinded observer using the SAS to subjectively determine their level of consciousness. Sedation levels varied from unarousable (SAS score of 1), to very sedated (SAS score of 2), to mildly sedated (SAS score of 3). Simultaneously, the patients were continuously monitored for 4-6 hrs with the BIS device. There was wide variability in BIS scores for any given level of consciousness as compared with the SAS. Unarousable patients had BIS scores ranging from 23 to 97, with a median score of 50 and an interquartile range of 24. Very sedated patients had BIS scores ranging from 35 to 98, with a median score of 68 and an interquartile range of 36. Mildly sedated patients had BIS scores ranging from 67 to 91, with a median score of 76 and an interquartile range of 8. Overall, there was a less than satisfactory correlation between BIS values and SAS scores (r =.36, p <.001). However, the correlation improved with subgroup analysis when BIS values associated with excessive muscle movement were excluded (r =.50, p <.001). CONCLUSIONS: The correlation between SAS and BIS scores was suboptimal and inconsistent in a heterogeneous group of critically ill patients. The generation of BIS hardware and software, studied herein, is neither reliable nor valid for routinely monitoring the level of consciousness in the critically ill patient. Excessive muscle movement by the patient is an important and spurious influence on BIS values and seriously undermines BIS reliability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prospective evaluation of the Sedation-Agitation Scale for adult critically ill patients
Riker, R. R., Picard, J. T., & Fraser, G. L. (1999) · Critical Care Medicine · doi:10.1097/00003246-199907000-00022 · Cited by 961
Cited by
Devlin, J. W., Skrobik, Y., Gélinas, C., Needham, D. M., Slooter, A. J. C., Pandharipande, P. P., Watson, P. L., Weinhouse, G. L., Nunnally, M. E., Rochwerg, B., et al. (2018) · Critical Care Medicine · doi:10.1097/ccm.0000000000003299 · Cited by 3,956
Ely, E. W., Truman, B., Shintani, A., Thomason, J. W. W., Wheeler, A. P., Gordon, S., Francis, J., Speroff, T., Gautam, S., Margolin, R., et al. (2003) · JAMA · doi:10.1001/jama.289.22.2983 · Cited by 1,707
Payen, J.-F., Chanques, G., Mantz, J., Hercule, C., Auriant, I., Leguillou, J.-L., Binhas, M., Genty, C., Rolland, C., & Bosson, J.-L. (2007) · Anesthesiology · doi:10.1097/01.anes.0000264747.09017.da · Cited by 570
Murray, M. J., DeBlock, H., Erstad, B., Gray, A., Jacobi, J., Jordan, C., McGee, W., McManus, C., Meade, M., Nix, S., et al. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000002027 · Cited by 517
Vivien, B., Di Maria, S., Ouattara, A., Langeron, O., Coriat, P., & Riou, B. (2003) · Anesthesiology · doi:10.1097/00000542-200307000-00006 · Cited by 292
Metadata
- Authors
- Nasraway, S. A., Wu, E. C., Kelleher, R. M., Yasuda, C. M., & Donnelly, A. M.
- Venue
- Critical Care Medicine
- Published
- 2002-07
- Volume
- 30
- Issue
- 7
- Pages
- 1483-1487
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2074666726
- Cited by
- 193
- References
- 1
- FWCI
- 25.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: How reliable is the Bispectral Index in critically ill patients? A prospective, comparative, single-blinded observer study*. https://app.cochat.ai/papers/10.1097/00003246-200207000-00014
- The paper
- Nasraway, S. A., Wu, E. C., Kelleher, R. M., Yasuda, C. M., & Donnelly, A. M. (2002). How reliable is the Bispectral Index in critically ill patients? A prospective, comparative, single-blinded observer study*. Critical Care Medicine. https://doi.org/10.1097/00003246-200207000-00014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.