The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Assessment of cardiac output from systemic arterial pressure in humans
Abstract
OBJECTIVE: To evaluate the reliability, by comparison with established techniques, of a new method to assess cardiac output, called pressure recording analytical method (PRAM), deriving from the analysis of the arterial pressure profile in the time domain the arterial-pressure-blood flow relationship. DESIGN: Criterion standard. SETTING: Hemodynamics laboratory at an university medical center. PATIENTS: Twenty-two hemodynamically stable cardiac patients scheduled for diagnostic right and left heart catheterization. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Cardiac index was simultaneously estimated by direct-oxygen Fick method, thermodilution, and PRAM applied to pressure signals recorded either invasively from an aortic catheter (PRAMa) or noninvasively at the finger (PRAMf) by photoplethysmography. Cardiac index values obtained by established techniques were significantly correlated with those estimated by PRAM: Fick method vs. PRAMa, r(2) =.88, vs. PRAMf, r(2) =.94; thermodilution vs. PRAMa, r(2) =.77, vs. PRAMf, r(2) =.77. The Bland-Altman analysis showed agreement between the Fick method and PRAM, with all data points comprised within the limits of agreement (+/-2SD) (mean difference +/- SD: -0.012 +/- 0.187 L x min(-1) x m(-2) for PRAMa; 0.024 +/- 0.167 L x min(-1) x m(-2) for PRAMf). Agreement was also found between thermodilution and PRAM, with all but one data point lying within the limits of agreement (mean difference +/- SD: -0.154 +/- 0.348 L x min(-1) x m(-2) for PRAMa; -0.108 +/- 0.348 L x min(-1) x m(-2) for PRAMf). CONCLUSIONS: In the range evaluated (cardiac index from 1.65 to 3.91 L x min(-1) x m(-2) by the Fick method), PRAM provides reliable invasive and noninvasive estimates of cardiac output in hemodynamically stable cardiac patients. PRAM may prove clinically useful for the beat-to-beat monitoring of cardiac output.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Computation of aortic flow from pressure in humans using a nonlinear, three-element model
Wesseling, K. H., Jansen, J. R., Settels, J. J., & Schreuder, J. J. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.5.2566 · Cited by 1,137
Hamilton, W. F., Moore, J. W., Kinsman, J. M., & Spurling, R. G. (1932) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1932.99.3.534 · Cited by 763
Langewouters, G. J., Wesseling, K. H., & Goedhard, W. J. A. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90034-4 · Cited by 544
Direct Blood Pressure Measurement —Dynamic Response Requirements
Gardner, R. M. (1981) · Anesthesiology · doi:10.1097/00000542-198103000-00010 · Cited by 518
HOWELL, W. H. (1909) · The American Journal of the Medical Sciences · doi:10.1097/00000441-190902000-00019 · Cited by 513
Die grundform des arteriellen pulses
Frank, O. (1899) · Medical Entomology and Zoology · Cited by 457
Cardiac catheterization and angiography
(1975) · American Heart Journal · doi:10.1016/0002-8703(75)90525-6 · Cited by 454
Measurement of blood flow by thermodilution
Ganz, W., & Swan, H. J. C. (1972) · The American Journal of Cardiology · doi:10.1016/0002-9149(72)90635-2 · Cited by 374
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Peyton, P. J., & Chong, S. W. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181ee3130 · Cited by 456
Less invasive hemodynamic monitoring in critically ill patients
Teboul, J.-L., Saugel, B., Cecconi, M., De Backer, D., Hofer, C. K., Monnet, X., Perel, A., Pinsky, M. R., Reuter, D. A., Rhodes, A., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4375-7 · Cited by 328
Low-Cardiac-Output Syndrome After Cardiac Surgery
Lomivorotov, V. V., Efremov, S. M., Kirov, M. Y., Fominskiy, E. V., & Karaskov, A. M. (2017) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2016.05.029 · Cited by 315
Noninvasive Cardiac Output Monitors: A State-of the-Art Review
Marik, P. E. (2013) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2012.03.022 · Cited by 293
Metadata
- Authors
- Romano, S. M., & Pistolesi, M.
- Venue
- Critical Care Medicine
- Published
- 2002-08
- Volume
- 30
- Issue
- 8
- Pages
- 1834-1841
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2041279543
- Cited by
- 616
- References
- 26
- FWCI
- 77.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of cardiac output from systemic arterial pressure in humans. https://app.cochat.ai/papers/10.1097/00003246-200208000-00027
- The paper
- Romano, S. M., & Pistolesi, M. (2002). Assessment of cardiac output from systemic arterial pressure in humans. Critical Care Medicine. https://doi.org/10.1097/00003246-200208000-00027
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.