The DOI matches its Crossref record.
Human Auditory Steady State Potentials
Abstract
The auditory steady state potentials may be an important technique in objective audiometry. The effects of stimulus rate, intensity, and tonal frequency on these potentials were investigated using both signal averaging and on-line Fourier analysis. Stimulus presentation rates of 40 to 45/sec result in a 40 Hz sinusoidal response which is about twice the amplitude of the 10 and 60/sec responses. No significant effects of subject age or sex were seen. The 40/sec response shows a linear decrease in amplitude and a linear increase in latency when stimulus intensity is decreased from 90 to 20 dB normal hearing level. This response is recordable to within a few decibels of behavioral threshold. Stimuli of different tonal frequency give similar amplitude/rate functions, with absolute amplitude decreasing with increasing tonal frequency. Signal averaging and Fourier analysis provide nearly identical amplitude/rate, amplitude/intensity, and latency/intensity functions. Both methods of analysis may be used, therefore, to record the 40 Hz steady state potential. Fourier analysis, however, may be the faster and less expensive method. Furthermore, techniques ("zoom") are available with Fourier analysis to study the effects of varying stimulus parameters on-line with the Fourier analysis procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Steady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066
Human auditory steady-state responses: Respuestas auditivas de estado estable en humanos
Picton, T. W., John, M. S., Dimitrijevic, A., & Purcell, D. (2003) · International Journal of Audiology · doi:10.3109/14992020309101316 · Cited by 846
Self-citationPhase-Locked Responses to Speech in Human Auditory Cortex are Enhanced During Comprehension
Peelle, J. E., Gross, J., & Davis, M. H. (2013) · Cerebral Cortex · doi:10.1093/cercor/bhs118 · Cited by 568
Intracerebral Sources of Human Auditory Steady-State Responses
Herdman, A. T., Lins, O., Van Roon, P., Stapells, D. R., Scherg, M., & Picton, T. W. (2002) · Brain Topography · doi:10.1023/a:1021470822922 · Cited by 389
Self-citationChildren and adolescents with autism exhibit reduced MEG steady-state gamma responses
Wilson, T. W., Rojas, D. C., Reite, M. L., Teale, P. D., & Rogers, S. J. (2007) · Biological Psychiatry · doi:10.1016/j.biopsych.2006.07.002 · Cited by 350
Metadata
- Authors
- Stapells, D. R., Linden, D., Suffield, J. B., Hamel, G., & Picton, T. W.
- Venue
- Ear and Hearing
- Published
- 1984-03
- Volume
- 5
- Issue
- 2
- Pages
- 105-113
- ISSN
- 0196-0202 (ISSN-L)
- OpenAlex
- W2052180202
- Cited by
- 246
- References
- 0
- FWCI
- 2.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Human Auditory Steady State Potentials. https://app.cochat.ai/papers/10.1097/00003446-198403000-00009
- The paper
- Stapells, D. R., Linden, D., Suffield, J. B., Hamel, G., & Picton, T. W. (1984). Human Auditory Steady State Potentials. Ear and Hearing. https://doi.org/10.1097/00003446-198403000-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.