Cortical, Auditory, Event-Related Potentials in Response to Periodic and Aperiodic Stimuli with the Same Spectral Envelope
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: 1) To determine whether the N1-P2 acoustic change complex is elicited by a change of periodicity in the middle of an ongoing stimulus, in the absence of changes of spectral envelope or rms intensity. 2) To compare the N1-P2 acoustic change complex with the mismatch negativity elicited by the same stimuli in terms of amplitude and signal to noise ratio. DESIGN: The signals used in this study were a tonal complex and a band of noise having the same spectral envelope and rms intensity. For elicitation of the acoustic change complex, the signals were concatenated to produce two stimuli that changed in the middle (noise-tone, tone-noise). Two control stimuli were created by concatenating two copies of the noise and two copies of the tone (noise-only, tone-only). The stimuli were presented using an onset-to-onset interstimulus interval of 3 sec. For elicitation of the mismatch negativity, the tonal complex and noise band stimuli were presented using an oddball paradigm (deviant probability = 0.14) with an onset-to-onset interstimulus interval of 600 msec. The stimuli were presented via headphones at 80 dB SPL to 10 adults with normal hearing. Subjects watched a silent video during testing. RESULTS: The responses to the noise-only and tone-only stimuli showed a clear N1-P2 complex to the onset of stimulation followed by a sustained potential that continued until the offset of stimulation. The noise-tone and tone-noise stimuli elicited an additional N1-P2 acoustic change complex in response to the change in periodicity occurring in the middle. The acoustic change complex was larger for the tone-noise stimulus than for the noise-tone stimulus. A clear mismatch negativity was elicited by both the noise band and tonal complex stimuli. In contrast to the acoustic change complex, there was no significant difference in amplitude across the two stimuli. The acoustic change complex was a more sensitive index of peripheral discrimination capacity than the mismatch negativity, primarily because its average amplitude was 2.5 times as large. CONCLUSIONS: These findings indicate that both the acoustic change complex and the mismatch negativity are sensitive indexes of the neural processing of changes in periodicity, though the acoustic change complex has an advantage in terms of amplitude. The results support the possible utility of the acoustic change complex as a clinical tool in the assessment of peripheral speech perception capacity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Näätänen, R., & Picton, T. (1987) · Psychophysiology · doi:10.1111/j.1469-8986.1987.tb00311.x · Cited by 3,321
Journal of Experimental Psychology: Human Perception and Performance.
Intons-Peterson, M. J. (1981) · Journal of Experimental Psychology: Human Perception and Performance · doi:10.1037/h0078016 · Cited by 3,183
Early selective-attention effect on evoked potential reinterpreted
Näätänen, R., Gaillard, A. W. K., & Mäntysalo, S. (1978) · Acta Psychologica · doi:10.1016/0001-6918(78)90006-9 · Cited by 2,706
Risto, N. (2018) · Routledge eBooks · doi:10.4324/9780429487354 · Cited by 2,024
A Solution for Reliable and Valid Reduction of Ocular Artifacts, Applied to the P300 ERP
Semlitsch, H. V., Anderer, P., Schuster, P., & Presslich, O. (1986) · Psychophysiology · doi:10.1111/j.1469-8986.1986.tb00696.x · Cited by 2,020
Auditory frequency discrimination and event-related potentials
Sams, M., Paavilainen, P., Alho, K., & Näätänen, R. (1985) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(85)90054-1 · Cited by 799
Journal of the American Academy of Audiology
(2020) · Journal of the American Academy of Audiology · doi:10.1055/s-00046128 · Cited by 787
Evoked dipole source potentials of the human auditory cortex
Scherg, M., & Von Cramon, D. (1986) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(86)90014-6 · Cited by 707
The sources of auditory evoked responses recorded from the human scalp
Vaughan, H. G., & Ritter, W. (1970) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(70)90228-2 · Cited by 693
Event-related brain potentials: an introduction
Coles, M. G. H., & Rugg, M. D. (1996) · Electrophysiology of Mind · doi:10.1093/acprof:oso/9780198524168.003.0001 · Cited by 396
Cited by
The mismatch negativity (MMN) in basic research of central auditory processing: A review
Näätänen, R., Paavilainen, P., Rinne, T., & Alho, K. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.04.026 · Cited by 2,644
“…Leppänen et al., 2002; Pihko et al., 1999, 2005; Csépe, 1995; Aulanko et al., 1993; Kraus et al., 1992, 1993a,b, 1995, 1996, 1999; Maiste et al., 1995; Martin and Boothroyd, 1999; Martin et al., 1999; Mathiak et al., 1999; McGee et al., 1996; Phillips et al., 2000; Rinne et al., 1999a;…”
Mismatch Negativity: Different Water in the Same River
Picton, T. W., Alain, C., Otten, L., Ritter, W., & Achim, A. (2000) · Audiology and Neurotology · doi:10.1159/000013875 · Cited by 578
Mismatch negativity (MMN), the deviance-elicited auditory deflection, explained
May, P. J. C., & Tiitinen, H. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2009.00856.x · Cited by 549
Speech Evoked Potentials: From the Laboratory to the Clinic
Martin, B. A., Tremblay, K. L., & Korczak, P. (2008) · Ear & Hearing · doi:10.1097/aud.0b013e3181662c0e · Cited by 357
Self-citationEffects of age and age-related hearing loss on the neural representation of speech cues
Tremblay, K. L., Piskosz, M., & Souza, P. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00114-7 · Cited by 354
Human Cortical Responses to the Speech Envelope
Aiken, S. J., & Picton, T. W. (2008) · Ear & Hearing · doi:10.1097/aud.0b013e31816453dc · Cited by 237
“…response to speech is sensitive to the characteristics of the glottal source (e.g., Mäkelä, et al., 2002, 2004; Tiitinen, et al., 2004), and the acoustic change complex can be elicited by changes in periodicity even in the absence of changes to the spectral envelope (Martin & Boothroyd, 1999).”
BackgroundInfluentialCortical, auditory, evoked potentials in response to changes of spectrum and amplitude
Martin, B. A., & Boothroyd, A. (2000) · The Journal of the Acoustical Society of America · doi:10.1121/1.428556 · Cited by 197
Self-citationOates, P. A., Kurtzberg, D., & Stapells, D. R. (2002) · Ear and Hearing · doi:10.1097/00003446-200210000-00002 · Cited by 172
“…recent evidence suggests that the presence of N1 might also signal the arrival of potentially discriminable information to the auditory cortex (Martin & Boothroyd, 1999); however, its presence does not imply that the stimulus contrast is discriminable (Martin, Reference Note 1; Martin et al.,…”
Background
Metadata
- Authors
- Martin, B. A., & Boothroyd, A.
- Venue
- Ear and Hearing
- Published
- 1999-02
- Volume
- 20
- Issue
- 1
- Pages
- 33-44
- ISSN
- 0196-0202 (ISSN-L)
- OpenAlex
- W2146614139
- Cited by
- 186
- References
- 37
- FWCI
- 0.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.