Threshold, Comfortable Level and Impedance Changes as a Function of Electrode-Modiolar Distance
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The study investigated the hypothesis that threshold and comfortable levels recorded from cochlear implant patients would reduce, and dynamic range increase, as distance of the electrode from the modiolar wall (radial distance) decreases. Two groups of cochlear implant patients participated; one group using the Nucleus' 24 Contour electrode array, and one group using the Nucleus standard straight (banded) array. The Nucleus 24 Contour array has been shown in temporal bone studies to lie closer to the modiolus than the banded array. The relationship of electrode impedance and radial distance is also investigated. DESIGN: The study, conducted at three centers, evaluated 21 patients using the Contour array, and 36 patients using the banded array. For each patient, threshold, comfortable levels and dynamic range were measured at four time points. Common ground electrode impedance was recorded clinically from each patient, at time intervals up to 12 wk. An estimate of the radial distance of the electrode from the modiolus was made by analysis of Cochlear view x-rays. RESULTS: Threshold and comfortable levels were significantly lower for the Nucleus 24 Contour array than for the banded array. However, dynamic range measurements did not show the predicted increase. In a majority of subjects, a significant correlation was found between the estimated radial distance of the electrode from the modiolus and the measured threshold and comfortable levels. This trend was not observed for dynamic range. The analysis indicates that other factors than radial distance are involved in the resultant psychophysical levels. Clinical impedance measures (common ground) were found to be significantly higher for the Contour array. However, the electrodes on the Contour array are half-rings, which are approximately only half the geometric size of the full rings as electrodes of the standard array. When the geometric electrode area in the two array designs are normalized, the trends in the electrode impedance behavior are similar. CONCLUSIONS: The results support the hypothesis that the relationship between the radial distance of the electrode and the psychophysical measures are influenced by patterns of fibrous tissue growth and individual patient differences, such as etiology and neural survival. Impedance measures for the Nucleus 24 Contour electrode array were higher than the banded electrode array, but this is primarily due to the reduction in electrode surface area. The different outcomes in impedance over time suggest differences in the relative contributions of the components of impedance with the two arrays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation
Shepherd, R. K., Hatsushika, S., & Clark, G. M. (1993) · Hearing Research · doi:10.1016/0378-5955(93)90265-3 · Cited by 360
Blamey, P. J., Pyman, B. C., Clark, G. M., Dowell, R. C., Gordon, M., Brown, A. M., & Hollow, R. D. (1992) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348949210100410 · Cited by 218
Frijns, J. H. M., de Snoo, S. L., & Schoonhoven, R. (1995) · Hearing Research · doi:10.1016/0378-5955(95)00090-q · Cited by 182
Models of Neural Responsiveness to Electrical Stimulation
Finley, C. C., Wilson, B. S., & White, M. W. (1990) · Springer eBooks · doi:10.1007/978-1-4612-3256-8_5 · Cited by 168
Spatial selectivity in a rotationally symmetric model of the electrically stimulated cochlea
Frijns, J. H. M., de Snoo, S. L., & ten Kate, J. H. (1996) · Hearing Research · doi:10.1016/0378-5955(96)00004-4 · Cited by 161
Cohen, L. T., Xu, J. Y., Xu, S. A., et al. (1996) · PubMed · Cited by 148
Self-citationBanded Intracochlear Electrode Array: Evaluation of Insertion Trauma in Human Temporal Bones
Shepherd, R. K., Pyman, B. C., Clark, G. M., & Webb, R. L. (1985) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348948509400112 · Cited by 128 · cited 2×
“Shepherd et al. (1993) measured the electrically evoked auditory brain stem response (EABR) to stimulation in the cat scala tympani for four different placements of the stimulating electrode.”
BackgroundResultThe Contour Electrode Array: Safety Study and Initial Patient Trials of a New Perimodiolar Design
Tykocinski, M., Saunders, E., Cohen, L. T., Treaba, C., Briggs, R. J. S., Gibson, P., Clark, G. M., & Cowan, R. S. C. (2001) · Otology & Neurotology · doi:10.1097/00129492-200101000-00007 · Cited by 114 · cited 3×
“After extensive temporal bone studies (Richter, Aschendorff, Lohnstein, Husstedt, Nagursky, & Laszig, 2001; Roland, Fishman, Alexiades, & Cohen, 2000; Tykocinski et al., 2001), in which the validity and acceptable safety of the design was confirmed, a number of patients were implanted with the Nucleus 24 Contour.”
BackgroundMethodSelf-citationComparison of electrode position in the human cochlea using various perimodiolar electrode arrays
Tykocinski, M., Cohen, L. T., Pyman, B. C., ROLANDJR, T., Treaba, C. G., Palamara, J. E. A., DAHM, M., Shepherd, R. K., Xu, J., & Cowan, R. S. (2000) · American Journal of Otolaryngology · doi:10.1016/s0196-0709(00)80010-1 · Cited by 112 · cited 1×
“Tykocinski et al. (2000) compared the insertion of three electrode designs; two precurved, and one positioner type of array in human temporal bones.”
BackgroundSelf-citationPsychophysics of a prototype peri-modiolar cochlear implant electrode array
Cohen, L. T., Saunders, E., & Clark, G. M. (2001) · Hearing Research · doi:10.1016/s0378-5955(01)00248-9 · Cited by 103
Self-citation
Cited by
An overview of cochlear implant electrode array designs
Dhanasingh, A., & Jolly, C. (2017) · Hearing Research · doi:10.1016/j.heares.2017.10.005 · Cited by 311
Cohen, L. T., Richardson, L. M., Saunders, E., & Cowan, R. S. C. (2003) · Hearing Research · doi:10.1016/s0378-5955(03)00096-0 · Cited by 220
Self-citationFactors affecting perceptual thresholds in epiretinal prostheses
de Balthasar, C., Patel, S., Roy, A., Freda, R., Greenwald, S., Horsager, A., Mahadevappa, M., Yanai, D., McMahon, M. J., Humayun, M. S., et al. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0696 · Cited by 204
The Development of the Nucleus® Freedom™ Cochlear Implant System
Patrick, J. F., Busby, P. A., & Gibson, P. J. (2006) · Trends in Amplification · doi:10.1177/1084713806296386 · Cited by 196
“This outcome was verified in a multicenter study with 21 adults implanted with the Contour electrode, which found significant positive correlations between radial distance from the modiolus and the current levels for hearing thresholds and comfortable listening levels for most subjects.(56) The Nucleus 24 Contour mult…”
Roland, J. T. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000167993.05007.35 · Cited by 192
Metadata
- Authors
- Saunders, E., Cohen, L., Aschendorff, A., Shapiro, W., Knight, M., Stecker, M., Richter, B., Waltzman, S., Tykocinski, M., Roland, T., Laszig, R., & Cowan, R.
- Venue
- Ear and Hearing
- Published
- 2002-02
- Volume
- 23
- Issue
- Supplement
- Pages
- 28S-40S
- ISSN
- 0196-0202 (ISSN-L)
- OpenAlex
- W2136048068
- Cited by
- 197
- References
- 12
- FWCI
- 3.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.