The Contour Electrode Array: Safety Study and Initial Patient Trials of a New Perimodiolar Design
Open accessThe DOI matches its Crossref record.
Abstract
OBJECTIVE: The aim of these studies was to investigate the insertion properties and safety of a new intracochlear perimodiolar electrode array design (Contour). BACKGROUND: An electrode array positioned close to the neural elements could be expected to reduce stimulation thresholds and might potentially reduce channel interaction. METHODS: Two sequential studies were conducted. In study 1, the Contour electrode array was inserted in 12 human temporal bones. After cochlear surface preparation, the position of the array was noted and the basilar membrane was examined for insertion damage. On the basis of the outcome of this temporal bone study, study 2 investigated the Contour array, mounted on a Nucleus CI-24 M device and implanted in three adult patients. RESULTS: Study I showed that in 10 temporal bones, the Contour array was positioned close to the modiolus, and the basilar membrane was intact. In the two remaining bones, the arrays had pierced the basilar membrane and were positioned in the scala vestibuli apical to the penetration. Statistical analysis showed an equivalent probability of insertion-induced damage of the two array designs. In study 2, image analysis indicated that the Contour electrodes were positioned closer to the modiolus than the standard Nucleus straight array. Lower T and C levels, but higher impedance values, were recorded from electrodes close to the modiolus. Initial speech perception data showed that all patients gained useful open-set speech perception, two patients achieving scores of 100% on sentence material 3 months postoperatively. CONCLUSIONS: The temporal bone studies showed the Contour electrode array to be generally positioned closer to the modiolus than the standard Nucleus straight array, and to have an equivalent probability of causing insertion-induced damage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
“Temporal bone studies of cochlear implant electrodes developed in the 1980’s and 1990’s demonstrated that severe insertion related trauma was prevalent with these first generation electrodes [127,138-147].”
BackgroundCohen, L. T., Richardson, L. M., Saunders, E., & Cowan, R. S. C. (2003) · Hearing Research · doi:10.1016/s0378-5955(03)00096-0 · Cited by 220
Self-citationThreshold, Comfortable Level and Impedance Changes as a Function of Electrode-Modiolar Distance
Saunders, E., Cohen, L., Aschendorff, A., Shapiro, W., Knight, M., Stecker, M., Richter, B., Waltzman, S., Tykocinski, M., Roland, T., et al. (2002) · Ear and Hearing · doi:10.1097/00003446-200202001-00004 · Cited by 197
“After extensive temporal bone studies (Richter, Aschendorff, Lohnstein, Husstedt, Nagursky, & Laszig, 2001; Roland, Fishman, Alexiades, & Cohen, 2000; Tykocinski et al., 2001), in which the validity and acceptable safety of the design was confirmed, a number of patients were implanted with the Nucleus 24 Contour.”
BackgroundMethodSelf-citationRebscher, S. J. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.08.0119 · Cited by 169
“Because the tip of the electrode array has been reported to be the direct cause of trauma in the majority of specimens with observed damage in previous studies [16– 17,19,21–22,35], the stiffness ratio of the terminal 6 mm of each array was used for statistical correlation with damage.”
BackgroundMethodCochlear Implants: Some Likely Next Steps
Wilson, B. S., Lawson, D. T., Müller, J. M., Tyler, R. S., & Kiefer, J. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121645 · Cited by 160
Metadata
- Authors
- Tykocinski, M., Saunders, E., Cohen, L. T., Treaba, C., Briggs, R. J. S., Gibson, P., Clark, G. M., & Cowan, R. S. C.
- Venue
- Otology & Neurotology
- Published
- 2001-01
- Volume
- 22
- Issue
- 1
- Pages
- 33-41
- ISSN
- 1531-7129 (ISSN-L)
- OpenAlex
- W2026497482
- Cited by
- 114
- References
- 0
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Contour Electrode Array: Safety Study and Initial Patient Trials of a New Perimodiolar Design. https://app.cochat.ai/papers/10.1097/00129492-200101000-00007
- The paper
- Tykocinski, M., Saunders, E., Cohen, L. T., Treaba, C., Briggs, R. J. S., Gibson, P., Clark, G. M., & Cowan, R. S. C. (2001). The Contour Electrode Array: Safety Study and Initial Patient Trials of a New Perimodiolar Design. Otology & Neurotology. https://doi.org/10.1097/00129492-200101000-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.