The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A Model for Cochlear Implant Electrode Insertion and Force Evaluation: Results with a New Electrode Design and Insertion Technique
Abstract
Objectives and Hypothesis: This study has the specific aim of evaluating the insertion characteristics of a new cochlear implant electrode. Techniques for evaluation of fluoroscopic real time mechanical insertion dynamics, histologic electrode position and trauma results, hydraulic force, and mechanical insertion forces are presented. In addition, this study should serve to present a novel model for cochlear implant electrode insertion evaluations. Study Design: Prospective analysis using a series of analytical techniques. Methods: All studies are conducted in fixed cadaveric temporal bones. Real time fluoroscopic insertion evaluations, histologic evaluations for trauma and electrode position in embedded bones, hydraulic measures, and mechanical intracochlear force measurements are conducted with a current and new electrode. Results: The Contour Advance electrode provides a more reliable and less traumatic insertion when deployed with the Advance Off Stylet technique. This is largely because of a reduction in intracochlear outer wall force generation. Fluoroscopic and histologic analysis reveal a smooth insertion without reliance on cochlear outer wall contact. No hydraulic forces were detected when measured from the superior semicircular canal ampulla. Conclusion: The model used for this study provides valuable information to cochlear implant surgeons and design engineers. The Contour Advance electrode, inserted with the Advance Off Stylet technique, represents an improvement over the Contour electrode inserted with the standard insertion technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
A model of safe levels for electrical stimulation
Shannon, R. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126616 · Cited by 526
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Role of Electrode Placement as a Contributor to Variability in Cochlear Implant Outcomes
Finley, C. C., Holden, T. A., Holden, L. K., Whiting, B. R., Chole, R. A., Neely, G. J., Hullar, T. E., & Skinner, M. W. (2008) · Otology & Neurotology · doi:10.1097/mao.0b013e318184f492 · Cited by 549
Impact of electrode design and surgical approach on scalar location and cochlear implant outcomes
Wanna, G. B., Noble, J. H., Carlson, M. L., Gifford, R. H., Dietrich, M. S., Haynes, D. S., Dawant, B. M., & Labadie, R. F. (2014) · The Laryngoscope · doi:10.1002/lary.24728 · Cited by 321
The cochlear implant: historical aspects and future prospects
Eshraghi, A. A., Nazarian, R., Telischi, F. F., Rajguru, S. M., Truy, E., & Gupta, C. (2012) · The Anatomical Record · doi:10.1002/ar.22580 · Cited by 285
Metadata
- Authors
- Roland, J. T.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 2005-08
- Volume
- 115
- Issue
- 8
- Pages
- 1325-1339
- ISSN
- 0023-852X (ISSN-L)
- 1531-4995
- OpenAlex
- W2143200041
- Cited by
- 192
- References
- 2
- FWCI
- 2.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Model for Cochlear Implant Electrode Insertion and Force Evaluation: Results with a New Electrode Design and Insertion Technique. https://app.cochat.ai/papers/10.1097/01.mlg.0000167993.05007.35
- The paper
- Roland, J. T. (2005). A Model for Cochlear Implant Electrode Insertion and Force Evaluation: Results with a New Electrode Design and Insertion Technique. The Laryngoscope. https://doi.org/10.1097/01.mlg.0000167993.05007.35
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.