Results from a European Clinical Investigation of the Nucleus?? Multichannel Auditory Brainstem Implant
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: This study was designed to investigate the perceptual benefits and potential risks of implanting the Nucleus(R) multichannel auditory brainstem implant. DESIGN: Between September 1992 and October 1997 a total of 27 subjects received a Nucleus 20- or 21-channel Auditory Brainstem Implant (ABI). All subjects involved in the trial had bilateral acoustic tumour as a result of neurofibromatosis type 2 (NF2) resulting in complete dysfunction of the VIIIth nerve. The study used each subject as their own control without a preoperative baseline because residual hearing, if existing, was destroyed at surgery by tumour removal. A battery of speech tests was conducted to evaluate each patient's performance and communication abilities. Tests were conducted, where possible, in the auditory-only, visual-only, and auditory-visual conditions at 3 days postoperatively (baseline), at 3-mo intervals for the first year and every 12 mo thereafter. A subjective performance questionnaire was administered together with an extensive neurological examination at each test interval. RESULTS: 27 subjects involved in this trial were successfully implanted with a Nucleus ABI. One subject died 2 days postoperatively due to a lung embolism unrelated to the device. Twenty-six subjects underwent device activation and all but one patient received auditory sensation at initial stimulation (96.2%). On average 8.6 (+/-4.2) of the available 21 electrodes were used in the patients' MAPs. Performance evaluation measures showed that the majority of users had access to auditory information such as environmental sound awareness together with stress and rhythm cues in speech that assist with lipreading. Although most subjects did not achieve any functional auditory-alone, open-set speech understanding, two subjects from this series (7.4%) did receive sufficient benefit to be able to use the ABI in conversation without lipreading. CONCLUSIONS: Although the medical risks and surgical complexity associated with ABI device implantation are far greater than those for a cochlear implant, the clinical results from this trial show that the Nucleus multichannel ABI is capable of providing a significant patient benefit over risk ratio for subjects suffering loss of hearing due to bilateral retrocochlear lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708 · cited 1×
“Electrical stimulation levels were monitored according to a published model for safe charge and charge density (McCreery et al., 1990; Shannon 1992).”
MethodA model of safe levels for electrical stimulation
Shannon, R. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126616 · Cited by 526 · cited 1×
“Electrical stimulation levels were monitored according to a published model for safe charge and charge density (McCreery et al., 1990; Shannon 1992).”
MethodSkinner, M. W., Clark, G. M., Whitford, L. A., Seligman, P., Staller, S. J., Shipp, D. B., Shallop, J. K., Everingham, C., Menapace, C., & Arndt, P. L. (1994) · PubMed · Cited by 322
Cochlear Implants in Adults and Children
Gates, G. A. (1995) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1995.03530240065043 · Cited by 211
Auditory Brainstem Implant: I. Issues in Surgical Implantation
Brackmann, D. E., Hitselberger, W. E., Nelson, R. A., Moore, J., Waring, M. D., Portillo, F., Shannon, R. V., & Telischi, F. F. (1993) · Otolaryngology–Head and Neck Surgery · doi:10.1177/019459989310800602 · Cited by 202 · cited 1×
“Implantation of the ABI (Brackmann et al., 1993) is an extension to the procedure used for the removal of an acoustic tumour combined with a mastoid bed excavation for seating the implant’s receiver/stimulator body as per a regular Nucleus CI22M surgery.”
MethodIEEE Transactions on Bio-Medical Engineering
(1965) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1965.4502362 · Cited by 166
Hitselberger, W. E., House, W. F., Edgerton, B. J., & Whitaker, S. (1984) · Otolaryngology · doi:10.1177/019459988409200111 · Cited by 133
The Multichannel Auditory Brain Stem Implant: Performance in Twenty Patients
OTTO, S., Shannon, R., Brackmann, D. E., Hitselberger, W. E., Staller, S. J., & Menapace, C. (1998) · Otolaryngology · doi:10.1016/s0194-5998(98)70304-3 · Cited by 105
Chronic microstimulation in the feline ventral cochlear nucleus: physiologic and histologic effects
McCreery, D. B., Yuen, T. G. H., & Bullara, L. A. (2000) · Hearing Research · doi:10.1016/s0378-5955(00)00190-8 · Cited by 90 · cited 1×
“It should be taken as the starting point for further investigation into designs of ABI that might better exploit the tonotopic arrangement within the CN such as penetrating electrodes (El-Kashlan 1999; El-Kashlan et al., 1991; McCreery et al., 1992, 1998, 2000).”
BackgroundMcCreery, D. B., Shannon, R. V., Moore, J. K., & Chatterjee, M. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736153 · Cited by 76 · cited 1×
“It should be taken as the starting point for further investigation into designs of ABI that might better exploit the tonotopic arrangement within the CN such as penetrating electrodes (El-Kashlan 1999; El-Kashlan et al., 1991; McCreery et al., 1992, 1998, 2000).”
Background
Cited by
Auditory Brainstem Implant (ABI): New Frontiers in Adults and Children
Colletti, V., Carner, M., Miorelli, V., Guida, M., Colletti, L., & Fiorino, F. (2005) · Otolaryngology–Head and Neck Surgery · doi:10.1016/j.otohns.2005.03.022 · Cited by 159
Self-citation
Metadata
- Authors
- Nevison, B., Laszig, R., Sollmann, W.-P., Lenarz, T., Sterkers, O., Ramsden, R., Fraysse, B., Manrique, M., Rask-Andersen, H., Garcia-Ibanez, E., Colletti, V., & von Wallenberg, E.
- Venue
- Ear and Hearing
- Published
- 2002-06
- Volume
- 23
- Issue
- 3
- Pages
- 170-183
- ISSN
- 0196-0202 (ISSN-L)
- OpenAlex
- W2077872750
- Cited by
- 168
- References
- 14
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Results from a European Clinical Investigation of the Nucleus?? Multichannel Auditory Brainstem Implant. https://app.cochat.ai/papers/10.1097/00003446-200206000-00002
- The paper
- Nevison, B., Laszig, R., Sollmann, W.-P., Lenarz, T., Sterkers, O., Ramsden, R., Fraysse, B., Manrique, M., Rask-Andersen, H., Garcia-Ibanez, E., Colletti, V., & von Wallenberg, E. (2002). Results from a European Clinical Investigation of the Nucleus?? Multichannel Auditory Brainstem Implant. Ear and Hearing. https://doi.org/10.1097/00003446-200206000-00002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.