A model of safe levels for electrical stimulation

Shannon, R.V.·1992·IEEE Transactions on Biomedical Engineering

Abstract

A model is presented that represents a large body of data on safety and damage levels of electrical stimulation. The predictions of the model are consistent with known principles of current flow and known mechanisms of damage around stimulating electrodes. It is proposed that limits on levels of electrical stimulation take into account the location of the electrode relative to the stimulated tissue and these limits can be computed algorithmically from the model.

Integrity signals

Registry

Crossref · 10.1109/10.126616

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Current-induced tissue damage during electrical stimulation was avoided by keeping stimulus charge density below the damage threshold boundary.

    “Current-induced tissue damage during electrical stimulation was avoided by keeping stimulus charge density below the damage threshold boundary (20, 21).”
  • The work of Shannon, McCreery et al., and Cogan et al. established guidelines for stimulation levels regarded as safe for the stimulated tissues and the materials of the stimulating electrodes.

    “The work of Shannon (21), McCreery et al. (47, 48), and Cogan et al. (20, 49) established some guidelines for stimulation levels that are regarded as safe both for the stimulated tissues and the materials of the stimulating electrodes.”
  • In Shannon's model, k should be selected between 1.5 and 2.0, with a k-value of 1.5 to 1.8 being most common.

    “k should be selected between 1.5 and 2.0 [65], with a k-value of 1.5 to 1.8 being most common [4].”
  • Shannon derived a model for safe stimulation largely based on experimental data by McCreery et al.

    “Shannon derived a model for safe stimulation [65] largely based on experimental data by McCreery et al. [64].”
  • Maximal tolerated stimulation pulse frequencies vary for different neural structures as demonstrated in a number of publications including the relatively low stimulus frequency tolerance of motor nerves when compared to examples in the central nervous system.

    “Maximal tolerated stimulation pulse frequencies vary for different neural structures as demonstrated in a number of publications including the relatively low stimulus frequency tolerance of motor nerves when compared to examples in the central nervous system [44, 65, 92].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Shannon, R. V.
Affiliations
House Clinic (US)
Corresponding author
Shannon, R.V.
Venue
IEEE Transactions on Biomedical Engineering
Published
1992-04
Volume
39
Issue
4
Pages
424-426
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2042728692
Cited by
526
References
5
Citations by year
2026: 36 · 2025: 29 · 2024: 24 · 2023: 39 · 2022: 27 · 2021: 38 · 2020: 29 · 2019: 33 · 2018: 32 · 2017: 27 · 2016: 26 · 2015: 30 · 2014: 24 · 2013: 19 · 2012: 13
FWCI
0.41
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (5r29dc000409-05)
  • U.S. Food and Drug Administration (FD-R-000686)
  • National Institute on Deafness and Other Communication Disorders (DC00409)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
Keywords
tissue damage, electric current, electrode placement
MeSH terms
Animals, Electric Stimulation, Electrodes, Equipment Design, Models, Biological, Safety

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review