Magnetic Field Dependence of 1/T1 of Protons in Tissue
The DOI matches its Crossref record.
Abstract
It is well established that the spin-lattice magnetic relaxation rate 1/T1 of solvent protons in homogeneous protein solutions increases dramatically as the magnetic field is reduced well below the traditional NMR range. For a 5% solution of protein of 10(5) Daltons, for example, 1/T1 increases from about 50% above the pure solvent rate at 20 MHz to five times the solvent rate at 0.01 MHz. At higher fields, the effect of protein on the relaxation rate decreases progressively toward zero. 1/T1 of solvent in erythrocyte suspension behaves similarly, indicating that extracellular water has ready access to intracellular protein. We now report analogous data for samples of various mammalian tissues: we find that the data can be accommodated within the conceptual framework developed earlier for analyzing homogeneous protein solutions. It appears that tissue water probes the macromolecular composition and structure in a tissue-specific fashion. The variation of 1/T1 with field differs for each tissue, and its magnitude at low fields varies by more than a factor of three, far more than does the water content of the tissues. The relevance to contrast in NMR imaging is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kimmich, R., & Anoardo, E. (2004) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2004.03.002 · Cited by 671
NMR field-cycling spectroscopy: principles and a]lications
Noack, F. (1986) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/0079-6565(86)80004-8 · Cited by 440
Field-cycling relaxometry of protein solutions and tissue: Implications for MRI
Koenig, S. H., & Brown, R. D. (1990) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/0079-6565(90)80008-6 · Cited by 363
Self-citationGillis, P., & Koenig, S. H. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910050404 · Cited by 353
Self-citationRelaxometry of brain: Why white matter appears bright in MRI
Koenig, S. H., Brown, R. D., Spiller, M., & Lundbom, N. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140306 · Cited by 298
Self-citationProjection angiograms of blood labeled by adiabatic fast passage
Dixon, W. T., Du, L. N., Faul, D. D., Gado, M., & Rossnick, S. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030311 · Cited by 282
A low-cost and shielding-free ultra-low-field brain MRI scanner
Liu, Y., Leong, A. T. L., Zhao, Y., Xiao, L., Mak, H. K. F., Tsang, A. C. O., Lau, G. K. K., Leung, G. K. K., & Wu, E. X. (2021) · Nature Communications · doi:10.1038/s41467-021-27317-1 · Cited by 261
Kimmich, R. (1997) · NMR · doi:10.1007/978-3-642-60582-6_15 · Cited by 218
Analysis of biological NMR relaxation data with continuous distributions of relaxation times
Kroeker, R. M., & Mark Henkelman, R. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90074-0 · Cited by 210
Magnetic resonance imaging for the evaluation of patients with occult cervical spine injury
Benzel, E. C., Hart, B. L., Ball, P. A., Baldwin, N. G., Orrison, W. W., & Espinosa, M. C. (1996) · Journal of Neurosurgery · doi:10.3171/jns.1996.85.5.0824 · Cited by 176
Advanced MRI techniques to improve our understanding of experience-induced neuroplasticity
Tardif, C. L., Gauthier, C. J., Steele, C. J., Bazin, P.-L., Schäfer, A., Schaefer, A., Turner, R., & Villringer, A. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.047 · Cited by 127
Wansapura (1999) · doi:10.1002/(sici)1522-2586(199904)9:4
Metadata
- Authors
- KOENIG, S. H., BROWN, R. D., ADAMS, D., EMERSON, D., & HARRISON, C. G.
- Venue
- Investigative Radiology
- Published
- 1984-03
- Volume
- 19
- Issue
- 2
- Pages
- 76-81
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2030661192
- Cited by
- 168
- References
- 0
- FWCI
- 8.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.