Influence of the Endothelial Glycocalyx on Cerebral Blood Flow in Mice
The DOI matches its Crossref record.
Abstract
The endothelial surface layer (glycocalyx) of cerebral capillaries may increase resistance to blood flow. This hypothesis was investigated in mice by intravenous administration of heparinase (2500 IU/kg body weight in saline), which cleaves proteoglycan junctions of the glycocalyx. Morphology was investigated by transmission electron microscopy. Cerebral perfusion velocity was recorded before and during heparinase or saline treatment using laser–Doppler flowmetry. In addition, cerebral blood flow (CBF) was measured 10 minutes after heparinase or saline treatment using the iodo[14 C]antipyrine method. Laser–Doppler flowmetry and CBF measurements were performed during normocapnia and severe hypercapnia (Pco 2: 120 mm Hg). After heparinase, morphology showed a reduced thickness of the glycocalyx in cortical microvessels by 43% ( P < 0.05) compared with saline-treated controls. Under normocapnic conditions, a 15% ( P < 0.05) transient increase of cerebral flow velocity occurred 2.5 to 5 minutes after heparinase injection. Laser–Doppler flow and CBF returned to control values ten minutes after the injection. However, during severe hypercapnia, heparinase treatment resulted in a persisting increase in laser–Doppler flow (6%, P < 0.05) and CBF (30%, P < 0.05). These observations indicate the existence of a flow resistance in cerebral capillaries exerted by the glycocalyx. The transient nature of the CBF increase during normocapnia may be explained by a vascular compensation that is exhausted during severe hypercapnia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Rational Approach to Perioperative Fluid Management
Chappell, D., Jacob, M., Hofmann-Kiefer, K., Conzen, P., & Rehm, M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e3181863117 · Cited by 909
Rehm, M., Bruegger, D., Christ, F., Conzen, P., Thiel, M., Jacob, M., Chappell, D., Stoeckelhuber, M., Welsch, U., Reichart, B., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.684852 · Cited by 669
Plasma Restoration of Endothelial Glycocalyx in a Rodent Model of Hemorrhagic Shock
Kozar, R. A., Peng, Z., Zhang, R., Holcomb, J. B., Pati, S., Park, P., Ko, T. C., & Paredes, A. (2011) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318210385c · Cited by 408
Mechanisms of stroke protection by physical activity
Endres, M., Gertz, K., Lindauer, U., Katchanov, J., Schultze, J., Schröck, H., Nickenig, G., Kuschinsky, W., Dirnagl, U., & Laufs, U. (2003) · Annals of Neurology · doi:10.1002/ana.10722 · Cited by 330
Self-citationTNF-α induced shedding of the endothelial glycocalyx is prevented by hydrocortisone and antithrombin
Chappell, D., Hofmann-Kiefer, K., Jacob, M., Rehm, M., Briegel, J., Welsch, U., Conzen, P., & Becker, B. F. (2009) · Basic Research in Cardiology · doi:10.1007/s00395-008-0749-5 · Cited by 287
Endothelial glycocalyx and coronary vascular permeability: the fringe benefit
Becker, B. F., Chappell, D., & Jacob, M. (2010) · Basic Research in Cardiology · doi:10.1007/s00395-010-0118-z · Cited by 277
Rehm, M., Zahler, S., Lötsch, M., Welsch, U., Conzen, P., Jacob, M., & Becker, B. F. (2004) · Anesthesiology · doi:10.1097/00000542-200405000-00025 · Cited by 276
Bruegger, D., Jacob, M., Rehm, M., Loetsch, M., Welsch, U., Conzen, P., & Becker, B. F. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00218.2005 · Cited by 265
Modulation of Endothelial Glycocalyx Structure under Inflammatory Conditions
Kolářová, H., Ambrůzová, B., Švihálková Šindlerová, L., Klinke, A., & Kubala, L. (2014) · Mediators of Inflammation · doi:10.1155/2014/694312 · Cited by 257
Hydrocortisone Preserves the Vascular Barrier by Protecting the Endothelial Glycocalyx
Chappell, D., Jacob, M., Hofmann-Kiefer, K., Bruegger, D., Rehm, M., Conzen, P., Welsch, U., & Becker, B. F. (2007) · Anesthesiology · doi:10.1097/01.anes.0000286984.39328.96 · Cited by 251
“Electron Microscopy Electron microscopy was performed using a lantha- num fixation in modification of a method described by Vogel et al.24 and Rehm et al.12 Statistical Analysis Data dealing with rates of flow, transport, or release are expressed per gram heart weight.”
MethodKutuzov, N., Flyvbjerg, H., & Lauritzen, M. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1802155115 · Cited by 250
A Historical Review of Brain Drug Delivery
Pardridge, W. M. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics14061283 · Cited by 219
Chappell, D., Jacob, M., Paul, O., Rehm, M., Welsch, U., Stoeckelhuber, M., Conzen, P., & Becker, B. F. (2009) · Circulation Research · doi:10.1161/circresaha.108.187831 · Cited by 218
Marechal, X., Favory, R., Joulin, O., Montaigne, D., Hassoun, S., Decoster, B., Zerimech, F., & Neviere, R. (2008) · Shock · doi:10.1097/shk.0b013e318157e926 · Cited by 210
“Thickness and hydraulic resistivity of the endothelial glycocalyx are among the principal determinants of organ blood flow (22) and red blood cell motion through capillaries (23, 24).”
BackgroundContrasting Effects of Colloid and Crystalloid Resuscitation Fluids on Cardiac Vascular Permeability
Jacob, M., Bruegger, D., Rehm, M., Welsch, U., Conzen, P., & Becker, B. F. (2006) · Anesthesiology · doi:10.1097/00000542-200606000-00018 · Cited by 210
“In addition, we assessed the integrity of the endothelial surface layer (ESL) and the tissue edema at the end of the different perfusion protocols by means of electron microscopy.(4,7) This article is featured in “This Month in Anesthesiology.”
MethodAntithrombin reduces shedding of the endothelial glycocalyx following ischaemia/reperfusion
Chappell, D., Jacob, M., Hofmann-Kiefer, K., Rehm, M., Welsch, U., Conzen, P., & Becker, B. F. (2009) · Cardiovascular Research · doi:10.1093/cvr/cvp097 · Cited by 188
“Electron microscopy was performed on hearts perfusion-fixed with a lanthanium nitrate glutaraldehyde solution in modification of a method described by Vogel et al.17 For immunohistochemistry, hearts were perfusion fixed and stored in 4% formaldehyde solution for 24 h. Paraffin sections (5 mm) were stained with monoclo…”
MethodJACOB, M., BRUEGGER, D., REHM, M., STOECKELHUBER, M., WELSCH, U., CONZEN, P., & BECKER, B. (2007) · Cardiovascular Research · doi:10.1016/j.cardiores.2006.11.021 · Cited by 180
“According to Vogel and coworkers [15], binding of La to the negative charges of the glycocalyx (heparan and chondroitin sulfates) stabilizes the structure during the fixation.”
BackgroundThe ‘third space’ – fact or fiction?
Jacob, M., Chappell, D., & Rehm, M. (2009) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2009.05.001 · Cited by 159
Jacob, M., Chappell, D., Hofmann-Kiefer, K., Conzen, P., Peter, K., & Rehm, M. (2007) · Der Anaesthesist · doi:10.1007/s00101-007-1235-4 · Cited by 51
Metadata
- Authors
- Vogel, J., Sperandio, M., Pries, A. R., Linderkamp, O., Gaehtgens, P., & Kuschinsky, W.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 2000-11
- Volume
- 20
- Issue
- 11
- Pages
- 1571-1578
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W2090858727
- Cited by
- 96
- References
- 0
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.