Physical and Physiological Specification of Magnetic Pulse Stimuli that Produce Cortical Damage in Rats
The DOI matches its Crossref record.
Abstract
The effects of transcranial magnetic pulse stimuli on the brain tissue of rats were examined. In Experiment I, 52 male albino rats received pulsed magnetic stimulation of the head. Stimulus intensity, number of stimulations, stimulated sites, and interval between last stimulation and sacrifice for neuropathological examination were varied. High stimulus intensity (2.8 T) and 100 or more stimulations produced clearly defined microvacuolar changes in the neuropil portion of cortical layers 2-6 (especially layers 3 and 4) in 12 of 24 animals. Fewer stimulations and lower intensities produced no such effects in 28 rats given that stimulation. Midline stimulation and stimulation over the left hemisphere produced similar results. No other brain, ocular, or spinal structures manifested such changes. Lesions were present in animals that had intervals up to 30 days between the last stimulation and perfusion. In Experiment II with 18 animals, compound motor action potentials (CMAPs) evoked by magnetic stimulation of the cortical motor area and recorded from the right lower extremity were examined. The electromyographic threshold was 0.83 T. Further increases in stimulus intensity produced increases in CMAP amplitude, up to approximately 1.9 T. It was noted that the lesion-producing intensity (2.8 T) was 0.9 T greater than the intensity needed for near-asymptotic reactions and was 3.4 times the CMAP threshold value.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rossi, S., Hallett, M., Rossini, P. M., & Pascual-Leone, A. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.08.016 · Cited by 5,367
Transcranial Magnetic Stimulation: Applications in Neuropsychiatry
George, M. S., Lisanby, S. H., & Sackeim, H. A. (1999) · Archives of General Psychiatry · doi:10.1001/archpsyc.56.4.300 · Cited by 496
Loo, C. K., McFarquhar, T. F., & Mitchell, P. B. (2008) · International Journal of Neuropsychopharmacology · doi:10.1017/s1461145707007717 · Cited by 264
Improvement of depression following transcranial magnetic stimulation
George, M. S., Nahas, Z., Kozel, F. A., Goldman, J., Molloy, M., & Oliver, N. (1999) · Current Psychiatry Reports · doi:10.1007/s11920-999-0020-2 · Cited by 39
Metadata
- Authors
- Matsumiya, Y., Yamamoto, T., Yarita, M., Miyauchi, S., & Kling, J. W.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 1992-04
- Volume
- 9
- Issue
- 2
- Pages
- 278-287
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2012661518
- Cited by
- 35
- References
- 0
- FWCI
- 0.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physical and Physiological Specification of Magnetic Pulse Stimuli that Produce Cortical Damage in Rats. https://app.cochat.ai/papers/10.1097/00004691-199204010-00008
- The paper
- Matsumiya, Y., Yamamoto, T., Yarita, M., Miyauchi, S., & Kling, J. W. (1992). Physical and Physiological Specification of Magnetic Pulse Stimuli that Produce Cortical Damage in Rats. Journal of Clinical Neurophysiology. https://doi.org/10.1097/00004691-199204010-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.