Continuous EEG and Evoked Potential Monitoring in the Neuroscience Intensive Care Unit
The DOI matches its Crossref record.
Abstract
As with other methods long used in intensive care units (ICU) and operating rooms (OR), the goal of neuroscience ICU continuous EEG (NICU-CEEG) and evoked potential (NICU-EP) monitoring is to extend our powers of observation to detect abnormalities at a reversible stage. EEG is an appropriate monitoring tool because it is linked to cerebral metabolism, is sensitive to ischemia and hypoxemia, correlates with cerebral topography, detects neuronal dysfunction at a reversible stage, and is the best method for detecting seizure activity. When applied systematically, it can impact medical decision-making in 81% of monitored patients. It is useful in monitoring precarious cerebral perfusion at the bedside, and it has revealed that nonconvulsive seizures, undetectable otherwise, occur in 34% of NICU patients. In convulsive status epilepticus, NICU-CEEG can help avoid undertreatment and overtreatment. In comatose patients, it can provide useful prognostic information as well as detect potentially treatable causes. Traditional impediments to its application are yielding to technological advances and educational efforts. Real-time digitized EEG in particular has been a major advance. Within limits, somatosensory evoked potential monitoring (ICU-SEP) is useful in the prognosis of coma, but it is less helpful in monitoring focal cerebral ischemia. Brainstem auditory evoked potential monitoring has a relatively restricted role in the NICU but is helpful in distinguishing structural from nonstructural causes of coma and can supplement ICU-SEP in predicting outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Detection of electrographic seizures with continuous EEG monitoring in critically ill patients
Claassen, J., Mayer, S. A., Kowalski, R. G., Emerson, R. G., & Hirsch, L. J. (2004) · Neurology · doi:10.1212/01.wnl.0000125184.88797.62 · Cited by 1,190
Lowenstein, D. H., & Alldredge, B. K. (1998) · New England Journal of Medicine · doi:10.1056/nejm199804023381407 · Cited by 568
Continuous electroencephalography in the medical intensive care unit*
Oddo, M., Carrera, E., Claassen, J., Mayer, S. A., & Hirsch, L. J. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a00604 · Cited by 406
Young, G. B. (2000) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200009000-00006 · Cited by 292
A Pervasive Approach to EEG‐Based Depression Detection
Cai, H., Han, J., Chen, Y., Sha, X., Wang, Z., Hu, B., Yang, J., Feng, L., Ding, Z., Chen, Y., et al. (2018) · Complexity · doi:10.1155/2018/5238028 · Cited by 288
Jette, N., Claassen, J., Emerson, R. G., & Hirsch, L. J. (2006) · Archives of Neurology · doi:10.1001/archneur.63.12.1750 · Cited by 244
“(%) of patients 117 (100) 51 (44) 46 (39) 27 (23) Epilepsy related 28 (24) 15 (28) 13 (28) 7 (26) Unexplained decreased mental status 18 (15) 9 (18) 9 (20) 4 (15) Congenital malformations† 16 (14) 4 (8) 4 (9) 3 (11) Hypoxia or anoxia 11 (9) 3 (6) 3 (7) 3 (11) Tumor 9 (8) 4 (8) 4 (9) 2 (7) Toxic-metabolic 9 (8) 3 (6) 3…”
Electrophysiological Transcortical Diaschisis After Cortical Photothrombosis in Rat Brain
Buchkremer-Ratzmann, I., August, M., Hagemann, G., & Witte, O. W. (1996) · Stroke · doi:10.1161/01.str.27.6.1105 · Cited by 233
Delanty, N., Vaughan, C. J., & French, J. A. (1998) · The Lancet · doi:10.1016/s0140-6736(98)02158-8 · Cited by 210
Pandian, J. D., Cascino, G. D., So, E. L., Manno, E., & Fulgham, J. R. (2004) · Archives of Neurology · doi:10.1001/archneur.61.7.1090 · Cited by 188
“%) of 23 patients with NCSE died in 1 study.4 A less favorable response to antiepileptic drug therapy in patients with NCSE has also been reported.22 Among 518 patients with status epilepticus, the first treatment regimen was successful in 55% of patients with overt GCSE but in only 15% of patients with subtle GCSE.20…”
BackgroundInfluentialContinuous EEG Monitoring in the Intensive Care Unit: Early Findings and Clinical Efficacy
Vespa, P. M., Nenov, V., & Nuwer, M. R. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199901000-00001 · Cited by 188
Continuous EEG Monitoring in the Neuroscience Intensive Care Unit and Emergency Department
Jordan, K. G. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199901000-00002 · Cited by 185
Self-citationJirsch, J., & Hirsch, L. J. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.11.312 · Cited by 185
“Whenever possible the American Academy of Neurology classification of evidence scheme is used (Appendix, for example, see Armon and Evans, 2005).”
MethodResultAutomatic EEG analysis during long-term monitoring in the ICU
Agarwal, R., Gotman, J., Flanagan, D., & Rosenblatt, B. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00009-1 · Cited by 176
“The EEG is an appropriate tool for monitoring because it provides a sensitive indication of cerebral metabolism, ischemia, hypoxia and neuronal dysfunction (Jordan, 1993).”
MethodLimperopoulos, C., Majnemer, A., Rosenblatt, B., Shevell, M. I., Rohlicek, C., Tchervenkov, C., & Gottesman, R. (2001) · Journal of Child Neurology · doi:10.1177/088307380101600702 · Cited by 48
Metadata
- Authors
- Jordan, K. G.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 1993-10
- Volume
- 10
- Issue
- 4
- Pages
- 445-475
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2067774950
- Cited by
- 227
- References
- 0
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.