Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,190

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Detection of electrographic seizures with continuous EEG monitoring in critically ill patients

Claassen, J., Mayer, S. A., Kowalski, R. G., Emerson, R. G., Hirsch, L. J. · 2004 · Neurology

Abstract

OBJECTIVE: To identify patients most likely to have seizures documented on continuous EEG (cEEG) monitoring and patients who require more prolonged cEEG to record the first seizure. METHODS: Five hundred seventy consecutive patients who underwent cEEG monitoring over a 6.5-year period were reviewed for the detection of subclinical seizures or evaluation of unexplained decrease in level of consciousness. Baseline demographic, clinical, and EEG findings were recorded and a multivariate logistic regression analysis performed to identify factors associated with 1) any EEG seizure activity and 2) first seizure detected after >24 hours of monitoring. RESULTS: Seizures were detected in 19% (n = 110) of patients who underwent cEEG monitoring; the seizures were exclusively nonconvulsive in 92% (n = 101) of these patients. Among patients with seizures, 89% (n = 98) were in intensive care units at the time of monitoring. Electrographic seizures were associated with coma (odds ratio [OR] 7.7, 95% CI 4.2 to 14.2), age <18 years (OR 6.7, 95% CI 2.8 to 16.2), a history of epilepsy (OR 2.7, 95% CI 1.3 to 5.5), and convulsive seizures during the current illness prior to monitoring (OR 2.4, 95% CI 1.4 to 4.3). Seizures were detected within the first 24 hours of cEEG monitoring in 88% of all patients who would eventually have seizures detected by cEEG. In another 5% (n = 6), the first seizure was recorded on monitoring day 2, and in 7% (n = 8), the first seizure was detected after 48 hours of monitoring. Comatose patients were more likely to have their first seizure recorded after >24 hours of monitoring (20% vs 5% of noncomatose patients; OR 4.5, p = 0.018). CONCLUSIONS: CEEG monitoring detected seizure activity in 19% of patients, and the seizures were almost always nonconvulsive. Coma, age <18 years, a history of epilepsy, and convulsive seizures prior to monitoring were risk factors for electrographic seizures. Comatose patients frequently required >24 hours of monitoring to detect the first electrographic seizure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1212/01.wnl.0000125184.88797.62

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 1,190

Metadata

Authors
Claassen, J., Mayer, S. A., Kowalski, R. G., Emerson, R. G., & Hirsch, L. J.
Venue
Neurology
Published
2004-05-25
Volume
62
Issue
10
Pages
1743-1748
ISSN
  • 0028-3878 (ISSN-L)
  • 1526-632X
OpenAlex
W2082136405
Cited by
1,190
References
9
FWCI
14.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of electrographic seizures with continuous EEG monitoring in critically ill patients. https://app.cochat.ai/papers/10.1212/01.wnl.0000125184.88797.62
The paper
Claassen, J., Mayer, S. A., Kowalski, R. G., Emerson, R. G., & Hirsch, L. J. (2004). Detection of electrographic seizures with continuous EEG monitoring in critically ill patients. Neurology. https://doi.org/10.1212/01.wnl.0000125184.88797.62

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.