Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 406

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Continuous electroencephalography in the medical intensive care unit*

Open access
Oddo, Mauro, Carrera, Emmanuel, Claassen, Jan, Mayer, Stephan A., Hirsch, Lawrence J.·2009·Critical Care Medicine

Abstract

OBJECTIVES: To examine predictors and the prognostic value of electrographic seizures (ESZs) and periodic epileptiform discharges (PEDs) in medical intensive care unit (MICU) patients without a primary acute neurologic condition. DESIGN: Retrospective study. SETTING: MICU in a university hospital. PATIENTS: A total of 201 consecutive patients admitted to the MICU between July 2004 and January 2007 without known acute neurologic injury and who underwent continuous electroencephalography monitoring (cEEG) for investigation of possible seizures or changes in mental status. INTERVENTION: None. MEASUREMENTS AND MAIN RESULTS: Median time from intensive care unit (ICU) admission to cEEG was 1 day (interquartile range 1-4). The majority of patients (60%) had sepsis as the primary admission diagnosis and 48% were comatose at the time of cEEG. Ten percent (n = 21) of patients had ESZs, 17% (n = 34) had PEDs, 5% (n = 10) had both, and 22% (n = 45) had either ESZs or PEDs. Seizures during cEEG were purely electrographic (no detectable clinical correlate) in the majority (67%) of patients. Patients with sepsis had a higher rate of ESZs or PEDs than those without sepsis (32% vs. 9%, p < 0.001). On multivariable analysis, sepsis at ICU admission was the only significant predictor of ESZs or PEDs (odds ratio 4.6, 95% confidence interval 1.9-12.7, p = 0.002). After controlling for age, coma, and organ dysfunction, the presence of ESZs or PEDs was associated with death or severe disability at hospital discharge (89% with ESZs or PEDs, vs. 39% if not; odds ratio 19.1, 95% confidence interval 6.3-74.6, p < 0.001). CONCLUSION: In this retrospective study of MICU patients monitored with cEEG, ESZs and PEDs were frequent, predominantly in patients with sepsis. Seizures were mainly nonconvulsive. Both seizures and periodic discharges were associated with poor outcome. Prospective studies are warranted to determine more precisely the frequency and clinical impact of nonconvulsive seizures and periodic discharges, particularly in septic patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e3181a00604

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

See all 406

Metadata

Authors
Oddo, M., Carrera, E., Claassen, J., Mayer, S. A., & Hirsch, L. J.
Venue
Critical Care Medicine
Published
2009-06
Volume
37
Issue
6
Pages
2051-2056
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2038622222
Cited by
406
References
27
FWCI
14.58
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous electroencephalography in the medical intensive care unit*. https://app.cochat.ai/papers/10.1097/ccm.0b013e3181a00604
The paper
Oddo, M., Carrera, E., Claassen, J., Mayer, S. A., & Hirsch, L. J. (2009). Continuous electroencephalography in the medical intensive care unit*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e3181a00604

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.