Continuous EEG Monitoring in the Intensive Care Unit: Early Findings and Clinical Efficacy
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
The assessment of the neurocritical care patient involves serial assessment of neurologic status using bedside clinical examination and a variety of periodic neurophysiologic testing. Continuous electroencephalographic (CEEG) monitoring in the intensive care unit offers a unique means to track neurologic function directly and regionally. CEEG is becoming more widespread with a growing but small body of literature. The purpose of this paper is to outline the current experience with intensive care unit CEEG monitoring. The basic methods and caveats are discussed. We review the underlying rationale for using CEEG which is that secondary neurologic injury commonly occurs in the intensive care unit and at times is hard to detect. CEEG has a proven role in detecting secondary injuries, namely seizures and brain ischemia. The basic tenets of establishing clinical effectiveness for CEEG in the ICU are discussed while acknowledging a need for further study of clinical effectiveness. We review our initial clinical experience of CEEG in 300 patients and outline the clinical efficacy in terms of cost reduction and improvement in outcome (P < 0.01) using CEEG. Finally, several controversial aspects of CEEG are enumerated, and the need for additional study to answer these pressing questions is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thresholds in cerebral ischemia - the ischemic penumbra.
Astrup, J., Siesjö, B. K., & Symon, L. (1981) · Stroke · doi:10.1161/01.str.12.6.723 · Cited by 2,820
Sundt, T. M., Sharbrough, F. W., Piepgras, D. G., Kearns, T. P., Messick, J. M., & Oʼfallon, W. M. (1982) · Survey of Anesthesiology · doi:10.1097/00132586-198226040-00005 · Cited by 718
Gan, T. J., Glass, P. S. A., Windsor, A. C. J., Payne, F. C., Rosow, C. E., Sebel, P. S., & Manberg, P. J. (1997) · Anesthesiology · doi:10.1097/00000542-199710000-00014 · Cited by 691
Young, B. G., Jordan, K. G., & Doig, G. S. (1996) · Neurology · doi:10.1212/wnl.47.1.83 · Cited by 668
Bergsneider, M., Hovda, D. A., Shalmon, E., Kelly, D. F., Vespa, P. M., Martin, N. A., Phelps, M. E., McArthur, D. L., Caron, M. J., Kraus, J. F., et al. (1997) · Journal of Neurosurgery · doi:10.3171/jns.1997.86.2.0241 · Cited by 639
Self-citationSeizures after head trauma: A population study
Annegers, J. F., Grabow, J. D., Groover, R. V., Laws, E. R., Elveback, L. R., & Kurland, L. T. (1980) · Neurology · doi:10.1212/wnl.30.7.683 · Cited by 550
SHARBROUGH, F. W., MESSICK, J. M., & SUNDT, T. M. (1973) · Stroke · doi:10.1161/01.str.4.4.674 · Cited by 489
Continuous monitoring of jugular venous oxygen saturation in head-injured patients
Sheinberg, M., Kanter, M. J., Robertson, C. S., Contant, C. F., Narayan, R. K., & Grossman, R. G. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.76.2.0212 · Cited by 422
Chan, K.-H., Miller, J. D., Dearden, N. M., Andrews, P. J. D., & Midgley, S. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.77.1.0055 · Cited by 397
Vespa, P., Prins, M., Ronne-Engstrom, E., Caron, M., Shalmon, E., Hovda, D. A., Martin, N. A., & Becker, D. P. (1998) · Journal of Neurosurgery · doi:10.3171/jns.1998.89.6.0971 · Cited by 334
Self-citationA Multicenter Study of Bispectral Electroencephalogram Analysis for Monitoring Anesthetic Effect
Sebel, P. S., Lang, E., Rampil, I. J., White, P. F., Cork, R., Jopling, M., Smith, N. T., Glass, P. S. A., & Manberg, P. (1997) · Anesthesia & Analgesia · doi:10.1213/00000539-199704000-00035 · Cited by 302
Benefit of neurophysiologic monitoring for pediatric cardiac surgery
Austin, E. H., Edmonds, H. L., Auden, S. M., Seremet, V., Niznik, G., Sehic, A., Sowell, M. K., Cheppo, C. D., & Corlett, K. M. (1997) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(97)70074-6 · Cited by 296
Synek, V. M. (1988) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-198804000-00003 · Cited by 269
Avoidable factors contributing to death after head injury.
Rose, J., Valtonen, S., & Jennett, B. (1977) · BMJ · doi:10.1136/bmj.2.6087.615 · Cited by 263
Continuous EEG and Evoked Potential Monitoring in the Neuroscience Intensive Care Unit
Jordan, K. G. (1993) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199310000-00006 · Cited by 227
Correlation between dominant EEG frequency, cerebral oxygen uptake and blood flow
Ingvar, D. H., Sjölund, B., & Ardö, A. (1976) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(76)90119-x · Cited by 214
BULLOCK, R., ZAUNER, A., MYSEROS, J. S., MARMAROU, A., WOODWARD, J. J., & YOUNG, H. F. (1995) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1995.tb16586.x · Cited by 161
Clinical application of compressed spectral array in long-term EEG monitoring of comatose patients
Bricolo, A., Turazzi, S., Faccioli, F., Odorizzi, F., Sciarretta, G., & Erculiani, P. (1978) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(78)90005-6 · Cited by 160
Kotila, M., & Waltimo, O. (1992) · Epilepsia · doi:10.1111/j.1528-1157.1992.tb01698.x · Cited by 160
The frequency, characteristics and prognosis of epileptic seizures at the onset of stroke.
Shinton, R. A., Gill, J. S., Melnick, S. C., Gupta, A. K., & Beevers, D. G. (1988) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.51.2.273 · Cited by 156
Neurophysiologic Monitoring in the Neuroscience Intensive Care Unit
Jordan, K. G. (1995) · Neurologic Clinics · doi:10.1016/s0733-8619(18)30035-5 · Cited by 145
Nagata, K., Tagawa, K., Hiroi, S., Shishido, F., & Uemura, K. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90027-8 · Cited by 143
TRAUMATIC EPILEPSY AFTER CLOSED HEAD INJURIES
Jennett, W. B., & Lewin, W. (1960) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.23.4.295 · Cited by 134
Goodman, J. C., Valadka, A. B., Gopinath, S. P., Cormio, M., & Robertson, C. S. (1996) · Journal of Neurotrauma · doi:10.1089/neu.1996.13.549 · Cited by 124
Selective Shunting with EEG Monitoring is Safer Than Routine Shunting for Carotid Endarterectomy
Salvian, A. J., Taylor, D. C., Hsiang, Y. N., Hildebrand, H. D., Litherland, H. K., Humer, M. F., Teal, P. A., & MacDonald, D. B. (1997) · Cardiovascular Surgery · doi:10.1016/s0967-2109(97)00044-6 · Cited by 98
Plestis, K. A., Loubser, P. G., Mizrahi, E. M., Kantis, G., Jiang, Z., & Howell, J. F. (1997) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(97)70287-8 · Cited by 95
Arnold, M., Sturzenegger, M., Schäffler, L., & Seiler, R. W. (1997) · Stroke · doi:10.1161/01.str.28.7.1345 · Cited by 89
EEG sleep patterns as a prognostic criterion in post-traumatic coma
Bergamasco, B., Bergamini, L., Doriguzzi, T., & Fabiani, D. (1968) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(68)90198-3 · Cited by 87
Evans, B. M., & Bartlett, J. R. (1995) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.59.1.17 · Cited by 83
Chatrian, G. E., Bergamasco, B., Bricolo, A. P., Frost, J. D., & Prior, P. F. (1996) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(96)96059-9 · Cited by 68
EEG monitoring of clinical coma
Karnaze, D. S., Marshall, L. F., & Bickford, R. G. (1982) · Neurology · doi:10.1212/wnl.32.3.289 · Cited by 65
Implantable cardioverter-defibrillator
Adams, D. C., Heyer, E. J., Emerson, R. G., Spotnitz, H. M., Delphin, E., Turner, C., & Berman, M. F. (1995) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(95)70290-3 · Cited by 42
Time-frequency spectral representation of the EEG as an Aid in the detection of depth of anesthesia
Nayak, A., Roy, R. J., & Sharma, A. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02367086 · Cited by 41
Dutton, R. C., Smith, W. D., & Smith, N. T. (1996) · The Journal of Clinical Monitoring · doi:10.1007/bf02078133 · Cited by 25
Epileptic seizures and cerebrovascular disease
Daniele, O., Mattaliano, A., Tassinari, C. A., & Natalè, E. (1989) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1989.tb03836.x · Cited by 23
Integrated Multimodality Monitoring in the Neurosurgical Intensive Care Unit
Miller, J. D., Piper, I., & Jones, P. A. (1994) · Neurosurgery Clinics of North America · doi:10.1016/s1042-3680(18)30493-5 · Cited by 22
Cited by
Consensus Statement on Continuous EEG in Critically Ill Adults and Children, Part I: Indications
Herman, S. T., Abend, N. S., Bleck, T. P., Chapman, K. E., Drislane, F. W., Emerson, R. G., Gerard, E. E., Hahn, C. D., Husain, A. M., Kaplan, P. W., et al. (2015) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000166 · Cited by 654
Self-citationContinuous electroencephalography in the medical intensive care unit*
Oddo, M., Carrera, E., Claassen, J., Mayer, S. A., & Hirsch, L. J. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a00604 · Cited by 406
Tsuchida, T. N., Wusthoff, C. J., Shellhaas, R. A., Abend, N. S., Hahn, C. D., Sullivan, J. E., Nguyen, S., Weinstein, S., Scher, M. S., Riviello, J. J., et al. (2013) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e3182872b24 · Cited by 394
Claassen, J., Hirsch, L. J., Kreiter, K. T., Du, E. Y., Sander Connolly, E., Emerson, R. G., & Mayer, S. A. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.017 · Cited by 393
Continuous Electroencephalogram Monitoring in the Intensive Care Unit
Friedman, D., Claassen, J., & Hirsch, L. J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181a9d8b5 · Cited by 309
Metadata
- Authors
- Vespa, P. M., Nenov, V., & Nuwer, M. R.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 1999-01
- Volume
- 16
- Issue
- 1
- Pages
- 1-13
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2011320585
- Cited by
- 188
- References
- 36
- FWCI
- 5.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.