Independent Component Analysis as a Tool to Eliminate Artifacts in EEG: A Quantitative Study
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Independent component analysis (ICA) is a novel technique that calculates independent components from mixed signals. A hypothetical clinical application is to remove artifacts in EEG. The goal of this study was to apply ICA to standard EEG recordings to eliminate well-known artifacts, thus quantifying its efficacy in an objective way. Eighty samples of recordings with spikes and evident artifacts of electrocardiogram (EKG), eye movements, 50-Hz interference, muscle, or electrode artifact were studied. ICA components were calculated using the Joint Approximate Diagonalization of Eigen-matrices (JADE) algorithm. The signal was reconstructed excluding those components related to the artifacts. A normalized correlation coefficient was used as a measure of the changes caused by the suppression of these components. ICA produced an evident clearing-up of signals in all the samples. The morphology and the topography of the spike were very similar before and after the removal of the artifacts. The correlation coefficient showed that the rest of the signal did not change significantly. Two examiners independently looked at the samples to identify the changes in the morphology and location of the discharge and the artifacts. In conclusion, ICA proved to be a useful tool to clean artifacts in short EEG samples, without having the disadvantages associated with the digital filters. The distortion of the interictal activity measured by correlation analysis was minimal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Independent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705
Independent Component Analysis
(2004) · Independent Component Analysis · doi:10.7551/mitpress/3717.003.0014 · Cited by 7,903
Removing electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
Blind signal separation: statistical principles
Cardoso, J.-F. (1998) · Proceedings of the IEEE · doi:10.1109/5.720250 · Cited by 1,885
Jung, T.-P., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00386-2 · Cited by 1,322
Independent component approach to the analysis of EEG and MEG recordings
Vigario, R., Sarela, J., Jousmiki, V., Hamalainen, M., & Oja, E. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841330 · Cited by 796
Ille, N., Berg, P., & Scherg, M. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200203000-00002 · Cited by 741
Calhoun, V. D., Adali, T., Pearlson, G. D., & Pekar, J. J. (2001) · Human Brain Mapping · doi:10.1002/hbm.1024 · Cited by 697
Extraction of ocular artefacts from EEG using independent component analysis
Vigário, R. N. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00042-8 · Cited by 639
Fetal electrocardiogram extraction by blind source subspace separation
de Lathauwer, L., de Moor, B., & Vandewalle, J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841326 · Cited by 502
Topographic Independent Component Analysis
Hyvärinen, A., Hoyer, P. O., & Inki, M. (2001) · Neural Computation · doi:10.1162/089976601750264992 · Cited by 459
Independent component analysis applied to feature extraction from colour and stereo images
Hoyer, P. O., & Hyvärinen, A. (2000) · Network Computation in Neural Systems · doi:10.1088/0954-898x/11/3/302 · Cited by 248
Independent component analysis at the neural cocktail party
Brown, G. D., Yamada, S., & Sejnowski, T. J. (2001) · Trends in Neurosciences · doi:10.1016/s0166-2236(00)01683-0 · Cited by 236
Blind Source Separation Using Temporal Predictability
Stone, J. V. (2001) · Neural Computation · doi:10.1162/089976601750265009 · Cited by 214
Sato, W., Kochiyama, T., Yoshikawa, S., & Matsumura, M. (2001) · Neuroreport · doi:10.1097/00001756-200103260-00019 · Cited by 207
Arfanakis, K., Cordes, D., Haughton, V. M., Moritz, C. H., Quigley, M. A., & Meyerand, M. E. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00190-9 · Cited by 191 · cited 1×
“It has also been used for MRI, positron emission tomograms, audiograms, and others (Arfanakis et al., 2000; Calhoun et al., 2001; Hoyer and Hyvarinen, 2000; Lee et al., 2001; Suzuki et al., 2002).”
MethodRemoving electroencephalographic artifacts: comparison between ICA and PCA
Jung, T.-P., Humphries, C., Lee, T.-W., Makeig, S., McKeown, M. J., Iragui, V., & Sejnowski, T. J. (2002) · Neural Networks for Signal Processing VIII. Proceedings of the 1998 IEEE Signal Processing Society Workshop (Cat. No.98TH8378) · doi:10.1109/nnsp.1998.710633 · Cited by 191
Independent component analysis for noisy data — MEG data analysis
Ikeda, S., & Toyama, K. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00071-x · Cited by 139
Tong, S., Bezerianos, A., Paul, J. S., Zhu, Y., & Thakor, N. V. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00366-1 · Cited by 91
Moritz, C. H., Haughton, V. M., Cordes, D., Quigley, M., & Meyerand, M. E. (2000) · PubMed · Cited by 89
A natural basis for efficient brain-actuated control
Makeig, S., Enghoff, S., Jung, T.-P., & Sejnowski, T. J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847818 · Cited by 82
Suzuki, K., Kiryu, T., & Nakada, T. (2001) · Human Brain Mapping · doi:10.1002/hbm.1061 · Cited by 54
Kobayashi, K., Akiyama, T., Nakahori, T., Yoshinaga, H., & Gotman, J. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00046-9 · Cited by 51
A new method for detecting state changes in the EEG: exploratory application to sleep data
McKeown, M. J., Humphries, C., Achermann, P., Borbély, A. A., & Sejnowsk, T. (1998) · Journal of Sleep Research · doi:10.1046/j.1365-2869.7.s1.8.x · Cited by 48
Spatially Fixed Patterns Account for the Spike and Wave Features in Absence Seizures
McKeown, M. J., Humphries, C., Iragui, V., & B, T. J. S. A. (1999) · Brain Topography · doi:10.1023/a:1023462211778 · Cited by 40
Kobayashi, K., Akiyama, T., Nakahori, T., Yoshinaga, H., & Gotman, J. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00047-0 · Cited by 34
Cited by
Delorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759
“to be an efficient method for separating distinct artifactual processes including eye blink, muscle and electrical artifacts (Barbati et al., 2004; Delorme et al., 2001; Iriarte et al., 2003; James and Gibson, 2003; Joyce et al., 2004; Jung et al., 2000b; Tran et al., 2004; Urrestarazu et al., 2004; Zhukov et al., 200…”
BackgroundMethodEEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
Castellanos, N. P., & Makarov, V. A. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.05.033 · Cited by 569
Canonical Correlation Analysis Applied to Remove Muscle Artifacts From the Electroencephalogram
Clercq, W. D., Vergult, A., Vanrumste, B., Van Paesschen, W., & Van Huffel, S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.879459 · Cited by 522
Metadata
- Authors
- Iriarte, J., Urrestarazu, E., Valencia, M., Alegre, M., Malanda, A., Viteri, C., & Artieda, J.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2003-07
- Volume
- 20
- Issue
- 4
- Pages
- 249-257
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2011957681
- Cited by
- 289
- References
- 26
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.