Independent Component Analysis as a Tool to Eliminate Artifacts in EEG: A Quantitative Study
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Independent component analysis (ICA) is a novel technique that calculates independent components from mixed signals. A hypothetical clinical application is to remove artifacts in EEG. The goal of this study was to apply ICA to standard EEG recordings to eliminate well-known artifacts, thus quantifying its efficacy in an objective way. Eighty samples of recordings with spikes and evident artifacts of electrocardiogram (EKG), eye movements, 50-Hz interference, muscle, or electrode artifact were studied. ICA components were calculated using the Joint Approximate Diagonalization of Eigen-matrices (JADE) algorithm. The signal was reconstructed excluding those components related to the artifacts. A normalized correlation coefficient was used as a measure of the changes caused by the suppression of these components. ICA produced an evident clearing-up of signals in all the samples. The morphology and the topography of the spike were very similar before and after the removal of the artifacts. The correlation coefficient showed that the rest of the signal did not change significantly. Two examiners independently looked at the samples to identify the changes in the morphology and location of the discharge and the artifacts. In conclusion, ICA proved to be a useful tool to clean artifacts in short EEG samples, without having the disadvantages associated with the digital filters. The distortion of the interictal activity measured by correlation analysis was minimal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Independent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705
Independent Component Analysis
(2004) · Independent Component Analysis · doi:10.7551/mitpress/3717.003.0014 · Cited by 7,903
Removing electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
Blind signal separation: statistical principles
Cardoso, J.-F. (1998) · Proceedings of the IEEE · doi:10.1109/5.720250 · Cited by 1,885
Jung, T.-P., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00386-2 · Cited by 1,322
Independent component approach to the analysis of EEG and MEG recordings
Vigario, R., Sarela, J., Jousmiki, V., Hamalainen, M., & Oja, E. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841330 · Cited by 796
Ille, N., Berg, P., & Scherg, M. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200203000-00002 · Cited by 741
Calhoun, V. D., Adali, T., Pearlson, G. D., & Pekar, J. J. (2001) · Human Brain Mapping · doi:10.1002/hbm.1024 · Cited by 697
Extraction of ocular artefacts from EEG using independent component analysis
Vigário, R. N. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00042-8 · Cited by 639
Fetal electrocardiogram extraction by blind source subspace separation
de Lathauwer, L., de Moor, B., & Vandewalle, J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841326 · Cited by 502
Cited by
Delorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759
“to be an efficient method for separating distinct artifactual processes including eye blink, muscle and electrical artifacts (Barbati et al., 2004; Delorme et al., 2001; Iriarte et al., 2003; James and Gibson, 2003; Joyce et al., 2004; Jung et al., 2000b; Tran et al., 2004; Urrestarazu et al., 2004; Zhukov et al., 200…”
BackgroundMethodEEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
Castellanos, N. P., & Makarov, V. A. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.05.033 · Cited by 569
Canonical Correlation Analysis Applied to Remove Muscle Artifacts From the Electroencephalogram
Clercq, W. D., Vergult, A., Vanrumste, B., Van Paesschen, W., & Van Huffel, S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.879459 · Cited by 522
Plöchl, M., Ossandón, J. P., & König, P. (2012) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00278 · Cited by 372
Seperability of four-class motor imagery data using independent components analysis
Naeem, M., Brunner, C., Leeb, R., Graimann, B., & Pfurtscheller, G. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/3/003 · Cited by 295
Wearable Sensing Technology Applications in Construction Safety and Health
Ahn, C. R., Lee, S., Sun, C., Jebelli, H., Yang, K., & Choi, B. (2019) · Journal of Construction Engineering and Management · doi:10.1061/(asce)co.1943-7862.0001708 · Cited by 290
BOLD correlates of EEG alpha phase-locking and the fMRI default mode network
Jann, K., Dierks, T., Boesch, C., Kottlow, M., Strik, W., & Koenig, T. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.01.001 · Cited by 286
“If the power inside the scanner clearly exceeded the power outside the scanner then these were identified as MR-related artifacts (Iriarte et al., 2003; Mantini et al., 2007a; Srivastava et al., 2005).”
MethodA system to detect the onset of epileptic seizures in scalp EEG
Saab, M. E., & Gotman, J. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.08.004 · Cited by 280
Srivastava, G., Crottaz-Herbette, S., Lau, K. M., Glover, G. H., & Menon, V. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.09.041 · Cited by 264
The Correction of Eye Blink Artefacts in the EEG: A Comparison of Two Prominent Methods
Hoffmann, S., & Falkenstein, M. (2008) · PLoS ONE · doi:10.1371/journal.pone.0003004 · Cited by 261
Identification and Removal of Physiological Artifacts From Electroencephalogram Signals: A Review
Mannan, M. M. N., Kamran, M. A., & Jeong, M. Y. (2018) · IEEE Access · doi:10.1109/access.2018.2842082 · Cited by 222
“In 2003, ICA was used for the first time to remove all types of artifacts from eighty EEG signals [15].”
BackgroundMethodInfluentialSafieddine, D., Kachenoura, A., Albera, L., Birot, G., Karfoul, A., Pasnicu, A., Biraben, A., Wendling, F., Senhadji, L., & Merlet, I. (2012) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/1687-6180-2012-127 · Cited by 198
Vecchio, F., Miraglia, F., Marra, C., Quaranta, D., Vita, M. G., Bramanti, P., & Rossini, P. M. (2014) · Journal of Alzheimer's Disease · doi:10.3233/jad-132087 · Cited by 182
“It has been proposed as an effective method for separating ocular movement and blink artifacts from EEG data [68–71].”
Zhang, H., Zhang, Y.-J., Lu, C.-M., Ma, S.-Y., Zang, Y.-F., & Zhu, C.-Z. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.02.080 · Cited by 182
“The feasibility of ICA on RSFC detection has been intensively demonstrated in fMRI (Greicius et al., 2004; Kiviniemi et al., 2003; van de Ven et al., 2004) and EEG/MEG (Hyvarinen et al., 2010; Iriarte et al., 2003; Scheeringa et al., 2008) studies.”
BackgroundValidation of SOBI components from high-density EEG
Tang, A. C., Sutherland, M. T., & McKinney, C. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.11.027 · Cited by 173
“First, more effective artifact removal than that offered by conventional approaches can be achieved (Barbati et al., 2004; Culpepper and Keller, 2003; Ikeda and Toyama, 2000; Iriarte et al., 2003; Joyce et al., 2004; Jung et al., 2000a,b; Kobayashi et al., 2001; Tang et al., 2000, 2002b; Tong et al., 2001; Vigario, 19…”
BackgroundSmart Wearables for the Detection of Cardiovascular Diseases: A Systematic Literature Review
Moshawrab, M., Adda, M., Bouzouane, A., Ibrahim, H., & Raad, A. (2023) · Sensors · doi:10.3390/s23020828 · Cited by 120
Vecchio, F., Miraglia, F., Alù, F., Menna, M., Judica, E., Cotelli, M., & Rossini, P. M. (2020) · Journal of Alzheimer’s Disease · doi:10.3233/jad-200171 · Cited by 73
Advances in Electrophysiological Research
Kamarajan, C. (2015) · Alcohol Research: Current Reviews · doi:10.35946/arcr.v37.1.05 · Cited by 72
“, ocular, cardiac, and muscular artifacts) can be removed (Iriarte et al. 2003).”
BackgroundInteroception is associated with heartbeat-evoked brain potentials (HEPs) in adolescents
Mai, S., Wong, C. K., Georgiou, E., & Pollatos, O. (2018) · Biological Psychology · doi:10.1016/j.biopsycho.2018.06.007 · Cited by 69
Neuner, I., Arrubla, J., Felder, J., & Shah, N. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.048 · Cited by 48
“Although ICA has been demonstrated to be a powerful tool for the correction of a variety of data artefacts (Iriarte et al., 2003; Jung et al., 2000), it still has the drawback of relying much on the algorithm applied for decomposition.”
Metadata
- Authors
- Iriarte, J., Urrestarazu, E., Valencia, M., Alegre, M., Malanda, A., Viteri, C., & Artieda, J.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2003-07
- Volume
- 20
- Issue
- 4
- Pages
- 249-257
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2011957681
- Cited by
- 289
- References
- 26
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.