Cited by 16Sleep and related disordersSubstance Abuse Treatment and OutcomesSleep and Work-Related Fatigue

The DOI matches its Crossref record.

Diazepam: Effects on Sleep and Withdrawal Phenomena

KALES, ANTHONY, SOLDATOS, CONSTANTIN R., BIXLER, EDWARD O., KALES, JOYCE D., VELA-BUENO, ANTONIO·1988·Journal of Clinical Psychopharmacology

Abstract

Diazepam 10 mg was evaluated in a sleep laboratory study of six insomniac subjects. The protocol, which lasted for 18 consecutive nights, including four placebo-baseline, seven drug, and seven placebo-withdrawal nights, allowed for assessment of initial and short-term drug effects, side effects, and any withdrawal effects. With initial drug use, there was a significant improvement in sleep. Further, there was little evidence of tolerance developing at the end of the 1-week drug administration period. During drug administration there was a mild degree of daytime sedation reported. After abrupt termination of diazepam, there was a moderate degree of sleep difficulty on the sixth withdrawal night when total wake time was increased by 34% above baseline (not significant). On other nights, mild withdrawal changes were noted. These findings for the short-term administration and withdrawal of diazepam contrast with those for rapidly eliminated benzodiazepine drugs. The latter are characterized by a rapid development of tolerance and more frequent and intense withdrawal sleep disturbances.

Overview

Integrity signals

Registry

Crossref · 10.1097/00004714-198810000-00006

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Another study demonstrated that alprazolam withdrawal causes more frequent and severe sleep disturbances compared with diazepam withdrawal.

    “Another study demonstrated that alprazolam withdrawal causes more frequent and severe sleep disturbances compared with diazepam withdrawal (Kales et al., 1988).”

    From A Review of Alprazolam Use, Misuse, and Withdrawal (2018) · cites this paper as Kales et al., 1988

Citations

Cited by

Sorted by citations

Metadata

Authors
KALES, A., SOLDATOS, C. R., BIXLER, E. O., KALES, J. D., & VELA-BUENO, A.
Affiliations
Pennsylvania State University (US)
Venue
Journal of Clinical Psychopharmacology
Published
1988-10
Volume
8
Issue
5
Pages
340???346
ISSN
0271-0749 (ISSN-L)
OpenAlex
W1980341373
Cited by
16
References
0
Citations by year
2023: 1 · 2021: 1 · 2017: 2
FWCI
1.57
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Clinical Psychopharmacology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Health Sciences › Medicine › Epidemiology › Substance Abuse Treatment and Outcomes
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and Work-Related Fatigue
Keywords
diazepam, insomnia, benzodiazepines, drug withdrawal, tolerance (pharmacology and immunology), daytime sedation, sleep quality, wake time
MeSH terms
Adult, Diazepam, Female, Humans, Male, Middle Aged, Sleep, Sleep Stages, Substance Withdrawal Syndrome

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review