Polychromatic Streak Artifacts in Computed Tomography Images
Abstract
A series of artifacts in computed tomography (CT) images, consisting of streaks coming off edges and flares surrounding the object being scanned, is shown to be due to polychromaticity of the X-ray beam. These artifacts are seldom seen on conventional CT brain scans. They are helpful in understanding artifacts such as those seen around the petrous bone of the skull. Following this, a comparison is made between "single energy" and "dual energy" correction schemes for poly-artifacts. The theoretical assumptions underlying either method are analyzed, and the importance of these concepts in dual energy reconstructions is stressed. A new test phantom is suggested to evaluate different poly-correction schemes. All the simulated projection data in this study are noise free and are reconstructed using an industrial convolution-back projection technique. In addition, reconstructions are shown of the phantom using real data taken with and without a water bag path length compensator.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The large extracranial metal components and dental cement of the implant can cause beam hardening that can appear as cupping, streaks, dark bands or flare in the μCT.
“the large extracranial metal components and dental cement of the implant can cause beam hardening that can appear as cupping, streaks, dark bands or flare in the µCT38–40.”
From Oxytocin neurons enable social transmission of maternal behaviour (2021) · cites this paper as [39]
Cited by
Sorted by citations
High resolution X-ray computed tomography: an emerging tool for small animal cancer research
Paulus, M. J., Gleason, S. S., Kennel, S. J., Hunsicker, P. R., & Johnson, D. K. (2000) · Neoplasia · doi:10.1038/sj.neo.7900069 · Cited by 490 · see citing works
An iterative maximum-likelihood polychromatic algorithm for CT
Man, B. D., Nuyts, J. L., Dupont, P. J., et al. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.959297 · Cited by 431 · see citing works
“A third approach is the dual energy approach [7], [16], [28]–[32].”
BackgroundMetal streak artifacts in X-ray computed tomography: a simulation study
Man, B. D., Nuyts, J. L., Dupont, P. J., et al. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775600 · Cited by 317 · see citing works
Oxytocin neurons enable social transmission of maternal behaviour
Carcea, I., Caraballo, N. L., Marlin, B. J., Ooyama, R., Riceberg, J. S., Mendoza Navarro, J. M., Opendak, M., Diaz, V. E., Schuster, L., Alvarado Torres, M. I., et al. (2021) · Nature · doi:10.1038/s41586-021-03814-7 · Cited by 268 · see citing works
Computerized tomography with X-ray, emission, and ultrasound sources
Kak, A. C. (1979) · Proceedings of the IEEE · doi:10.1109/proc.1979.11440 · Cited by 267 · see citing works
A New Algorithm for Metal Artifact Reduction in Computed Tomography
Mahnken, A. H., Raupach, R., Wildberger, J. E., et al. (2003) · Investigative Radiology · doi:10.1097/01.rli.0000086495.96457.54 · Cited by 227 · see citing works
Meganck, J. A., Kozloff, K. M., Thornton, M. M., et al. (2009) · Bone · doi:10.1016/j.bone.2009.07.078 · Cited by 186 · see citing works
“This corrects for beam hardening and can be used to minimize cupping, streak, and flare artifacts [10,12,13].”
Jin, P., Bouman, C. A., & Sauer, K. D. (2015) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2015.2461492 · Cited by 165 · see citing works
Reconstruction algorithm for polychromatic CT imaging: application to beam hardening correction
Yan, C. H., Whalen, R. T., Beaupré, G. S., et al. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.832955 · Cited by 144 · see citing works
Joseph, P. M., & Ruth, C. (1997) · Medical Physics · doi:10.1118/1.597970 · Cited by 111 · see citing works
Application of Polychromatic µCT for Mineral Density Determination
Zou, W. P., Hunter, N., & Swain, M. V. (2010) · Journal of Dental Research · doi:10.1177/0022034510378429 · Cited by 94 · see citing works
“Beam hardening also results in artifacts that appear as cupping, streaks, dark bands, or flare artifacts (Duerinckx and Macovski, 1978; Joseph and Spital, 1978; Barrett and Keat, 2004).”
BackgroundAn energy-based beam hardening model in tomography
de Casteele, E. V., Dyck, D. V., Sijbers, J., et al. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/23/305 · Cited by 91 · see citing works
Metal artifact reduction strategies for improved attenuation correction in hybrid PET/CT imaging
Abdoli, M., Dierckx, R., & Zaidi, H. (2012) · Medical Physics · doi:10.1118/1.4709599 · Cited by 88 · see citing works
A model-based correction method for beam hardening artefacts in X-ray microtomography
de Casteele, E. V., Dyck, D. V., Sijbers, J., et al. (2004) · Journal of X-Ray Science and Technology · doi:10.3233/xst-2004-00100 · Cited by 78 · see citing works
“Therefore, the intensities in the projection images are not proportional to the object thickness, causing pronounced edges, streaks, and environmental artefacts in the reconstructed image [2,3,11,14].”
Bueno, M. R., Estrela, C., de Figueiredo, J. A. P., et al. (2010) · Journal of Endodontics · doi:10.1016/j.joen.2010.08.006 · Cited by 71 · see citing works
Specimen size and porosity can introduce error into μCT-based tissue mineral density measurements
Fajardo, R. J., Cory, E., Patel, N., et al. (2008) · Bone · doi:10.1016/j.bone.2008.08.118 · Cited by 61 · see citing works
“research and a variety of studies have reported methodological variations [70,77–89].”
Remeysen, K., & Swennen, R. (2005) · International Journal of Coal Geology · doi:10.1016/j.coal.2005.10.001 · Cited by 55 · see citing works
Statistical Image Reconstruction for Inconsistent CT Projection Data
Oehler, M., & Buzug, T. M. (2007) · Methods of Information in Medicine · doi:10.1160/me9041 · Cited by 51 · see citing works
“This beam hardening effect is prominent for metals such as dental fillings or hip prostheses [1-6] and leads to inconsistencies in the Radon or projection space, respectively.”
BackgroundLocus coeruleus activity improves cochlear implant performance
Glennon, E., Valtcheva, S., Zhu, A., et al. (2022) · Nature · doi:10.1038/s41586-022-05554-8 · Cited by 42 · see citing works
Metal streak artifacts in X-ray computed tomography: a simulation study
Man, B. D., Nuyts, J. L., Dupont, P. J., et al. (2002) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.1998.773898 · Cited by 42 · see citing works
Ay, M. R., Mehranian, A., Maleki, A., et al. (2012) · Physica Medica · doi:10.1016/j.ejmp.2012.03.005 · Cited by 35 · see citing works
Hampel, U. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-823015-2.00029-7 · Cited by 29 · see citing works
Peterzol, A., Létang, J. M., & Babot, D. (2008) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2008.07.005 · Cited by 28 · see citing works
Micro-CT-based identification of double porosity in fired clay ceramics
Kariem, H., Hellmich, C., Kiefer, T., et al. (2018) · Journal of Materials Science · doi:10.1007/s10853-018-2281-9 · Cited by 25 · see citing works
A simulation study of motion artefacts in computed tomography
Yang, C.-K., Orphanoudakis, S. C., & Strohbehn, J. W. (1982) · Physics in Medicine and Biology · doi:10.1088/0031-9155/27/1/005 · Cited by 18 · see citing works
Ultrasonic Imaging by Reconstructive Tomography
Wade, G. (1980) · Acoustical imaging · doi:10.1007/978-1-4684-3755-3_24 · Cited by 18 · see citing works
Beyer, T., Townsend, D. W., Nutt, R., et al. (2000) · Steinkopff eBooks · doi:10.1007/978-3-642-57703-1_10 · Cited by 16 · see citing works
Ivakhnenko, V. I. (2010) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2010.2042066 · Cited by 15 · see citing works
“The dual-energy approach [5], [22], [29]–[33] draws re-”
Estrela, C., Estrela, C., Bueno, M. R., et al. (2011) · Dental Press Endodontics · doi:10.14436/2178-3713.1.1.028-036.oar · Cited by 15 · see citing works
Denoising of polychromatic CT images based on their own noise properties
Kim, J. H., Chang, Y., & Ra, J. B. (2016) · Medical Physics · doi:10.1118/1.4945022 · Cited by 14 · see citing works
Region of interest micro-CT of the middle ear: A practical approach
Gea, S. L. R., Decraemer, W. F. S., & Dirckx, J. J. J. (2005) · Journal of X-Ray Science and Technology · doi:10.3233/xst-2005-00135 · Cited by 14 · see citing works
“In Table 1 can be seen that Aluminium has a density coefficient close to that of bone tissue, while Plexiglass is close to soft biological tissue or water [14,15].”
X-ray attenuation models to account for beam hardening in computed tomography
Yang, Q., Fullagar, W. K., Myers, G. R., et al. (2020) · Applied Optics · doi:10.1364/ao.402304 · Cited by 13 · see citing works
Hampel, U. (2015) · Elsevier eBooks · doi:10.1016/b978-1-78242-118-4.00006-x · Cited by 13 · see citing works
Modified MLEM Algorithm for Artifact Suppression in CT
Oehler, M., & Buzug, T. M. (2006) · 2006 IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2006.353757 · Cited by 13 · see citing works
“Toreveal theinfluence oftheconfidence parameter onthe overall imagequality, theRMS error ( 4 )ofthedifference imagebetween theground truth reference imageFig. 5aand theimages reconstructed withtheX-MLEMapproach is evaluated within its entire interval ofdefinition 0<X< 1.Fig. 6showsthefunctional dependence ofRMS versus…”
BackgroundMethodInfluentialSoft tissue variations influence HR-pQCT density measurements in a spatially dependent manner
Wu, P., Gupta, T., Chang, H., Petrenko, D. M., Schafer, A. L., & Kazakia, G. J. (2020) · Bone · doi:10.1016/j.bone.2020.115505 · Cited by 12 · see citing works
Dual energy CT tissue quantitation for Monte-Carlo based treatment planning for brachytherapy
Dević, S., Monroe, J. I., Mutic, S., et al. (2002) · doi:10.1109/iembs.2000.900750 · Cited by 11 · see citing works
Noise factor of a polyenergetic X-ray beam in computed tomography
Morgenthaler, D. G., Brooks, R. A., & Talbert, A. J. (1980) · Physics in Medicine and Biology · doi:10.1088/0031-9155/25/2/005 · Cited by 11 · see citing works
AN OPTIMIZED COMPUTED TOMOGRAPHY PROTOCOL FOR METALLIC GUNSHOT HEAD TRAUMA IN A SEAL MODEL
Fraga‐Manteiga, E., Shaw, D. J., Dennison, S., et al. (2014) · Veterinary Radiology & Ultrasound · doi:10.1111/vru.12146 · Cited by 10 · see citing works
Acquisition Schemes for Combined 18F-FDG-PET/CT Imaging: An European Experience
Beyer, T., Antoch, G., Kühl, H., et al. (2004) · Springer eBooks · doi:10.1007/978-3-642-18517-5_5 · Cited by 8 · see citing works
Computer tomography for virtual models in dental imaging
Natali, A., & Viola, M. (2003) · CRC Press eBooks · doi:10.1201/9780203514849.ch3 · Cited by 8 · see citing works
Oxytocin Neurons Enable Social Transmission of Maternal Behavior
Carcea, I., Caraballo, N. L., Marlin, B. J., Ooyama, R., Riceberg, J. S., Mendoza Navarro, J. M., Opendak, M., Diaz, V. E., Schuster, L., Alvarado Torres, M. I., et al. (2019) · doi:10.1101/845495 · Cited by 8 · see citing works
Gustschin, N., Gustschin, A., Epple, F. M., et al. (2019) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/125/38003 · Cited by 7 · see citing works
Hasslinger, P., Vass, V., Dejaco, A., et al. (2016) · International Journal for Computational Methods in Engineering Science and Mechanics · doi:10.1080/15502287.2016.1145762 · Cited by 7 · see citing works
PET and PET/CT: Basic Principles and Instrumentation
Martínez, M.-J., Ziegler, S., & Beyer, T. (2008) · Recent results in cancer research/Recent Results in Cancer Research · doi:10.1007/978-3-540-31203-1_1 · Cited by 7 · see citing works
Ri-Feng, Z., Wang, J., & Chen, W. (2009) · Chinese Physics C · doi:10.1088/1674-1137/33/7/018 · Cited by 7 · see citing works
Industrial computed tomography system for aerospace applications: development and characterisation
Reddy, M. V., Lukose, S. N., Subramanian, M. P., et al. (2011) · Insight - Non-Destructive Testing and Condition Monitoring · doi:10.1784/insi.2011.53.6.307 · Cited by 6 · see citing works
Use of X‐Ray Tomography for Drying‐Related Applications
Léonard, A., Crine, M., & Štĕpánek, F. (2014) · doi:10.1002/9783527631728.ch11 · Cited by 6 · see citing works
Arentsen, L., & Hui, S. K. (2013) · Microscopy and Microanalysis · doi:10.1017/s1431927613001396 · Cited by 5 · see citing works
Ghafarzadeh, M., Kejani, M. T., Karimi, M., et al. (2023) · Journal of Nondestructive Evaluation Diagnostics and Prognostics of Engineering Systems · doi:10.1115/1.4063805 · Cited by 4 · see citing works
An Application Approach to Kalman Filter and CT Scanners for Soil Science
Laia, M. A. M., & Almeida, P. E. M. (2011) · InTech eBooks · doi:10.5772/31030 · Cited by 3 · see citing works
“…as polychromatic sources (non-ideal or monochromatic), caused by the following effects: beam hardening, aliasing, different materials in the same voxel (partial volume), displacement of the sample or of the equipment (Duerinckx & Macocski, 1978; Joseph & Spital, 1978; Ibbott, 1980; Granato, 1998).”
BackgroundClinical investigation of the acute cerebrovascular disease
Mitsuyama, F., ISHIYAMA, N., Katada, K., et al. (1980) · Nosotchu · doi:10.3995/jstroke.2.326 · Cited by 3 · see citing works
Use of X‐Ray Tomography for Drying‐Related Applications
Léonard, A., Crine, M., & Štĕpánek, F. (2008) · doi:10.1002/9783527631643.ch4 · Cited by 3 · see citing works
Technical Artifacts in PET-CT Imaging
Beyer, T. (2010) · Springer eBooks · doi:10.1007/978-0-387-48902-5_5 · Cited by 2 · see citing works
“High-density implants, such as dental fillings, pacemakers, prostheses, or chemotherapy infusion ports may seriously distort the CT images [ 30 , 31].”
BackgroundUnraveling Microscale Flow and Pore Geometry: NMRI and X-Ray Tomography
Alvarez-Benedi, J., & Munoz-Carpena, R. (2004) · CRC Press eBooks · doi:10.1201/9781420032086-11 · Cited by 2 · see citing works
Soil Science Tomographic Projections Filtering using Discret Kalman and Neural Networks
Laia, M. A. M., & Cruvinel, P. E. (2008) · IEEE Latin America Transactions · doi:10.1109/tla.2008.4461640 · Cited by 2 · see citing works
Ciassification of Artifacts in X-Ray Cr Images Due to Nonlinear Shadows
Duerinckx, A. J., & Macovski, A. (1979) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1979.4330548 · Cited by 2 · see citing works
Self-citation4. Measurement of Projection Data—The Nondiffracting Case
(2001) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898719277.ch4 · Cited by 1 · see citing works
Signal Optimization in Electron Tomography
Maiorca, M., & Rosenthal, P. B. (2017) · Biological and medical physics, biomedical engineering · doi:10.1007/978-3-319-68997-5_11 · Cited by 1 · see citing works
Rapalino, O., Kamalian, S., Gupta, R., Phan, C. M., Pomerantz, S. R., Romero, J. M., Joshi, M. C., & Lev, M. H. (2010) · Medical radiology · doi:10.1007/174_2010_32 · Cited by 2 · see citing works
Walimuni, I. S., Kouri, D. J., Papadakis, M., et al. (2007) · IEEE International Symposium on Biomedical Imaging: From Nano to Macro (ISBI) · doi:10.1109/isbi.2007.356980 · Cited by 1 · see citing works
“The final reconstructed image is significantly affected by this phenomenon, causing various artifacts in the image [1, 7, 8, 9, 10, 11, 13, 14].”
BackgroundAnato-Molecular Imaging: Combining Structure and Function
Townsend, D. W., & Beyer, T. (2005) · Springer eBooks · doi:10.1007/1-84628-007-9_8 · Cited by 1 · see citing works
“High-density implants, such as dental fillings, pacemakers, prostheses, or chemotherapy infusion ports may lead to serious artefacts in CT images [ 74 , 75].”
BackgroundA model-based correction method for beam hardening artefacts in X-ray tomography
de Casteele, E. V., Dyck, D. V., Sijbers, J., et al. (2003) · Cited by 1 · see citing works
Simplified patient positioning to reduce beam hardening in CT of the lower neck.
Harvey, G. D., Mayer, D. P., & Radecki, P. D. (1984) · PubMed
A bimodal energy model for correcting beam hardening artefacts in X-ray tomography
de Casteele, E. V., Dyck, D. V., Sijbers, J., et al. (2003) · doi:10.1109/nebc.2003.1215990
Interpretation of Periapical Lesions Using Cone Beam Computed Tomography
Estrela, C., Bueno, M. R., & de Alencar, A. H. G. (2012) · doi:10.1002/9781119421689.ch21
Unraveling Microscale Flow and Pore Geometry
Deurer, M., & Clothier, B. (2004) · CRC Press eBooks · doi:10.1201/9781420032086.ch7
Computer tomography for virtual models in dental imaging AN NATALI, MM VIOLA
AN Natali, M. V. (2003) · CRC Press eBooks · doi:10.1201/9780203514849-6
Novel method of attenuation-based estimating patient size from single CT localizer radiograph
Lee, C.-L., Han, K., & Cho, M. (2022) · Journal of the Korean Physical Society · doi:10.1007/s40042-022-00520-z
Polychromatic neural CBCT reconstruction through density-attenuation modeling
Birklein, L., Schömer, E., Schwanecke, U., et al. (2025) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ae28af
“More specifically, tissues or materials depending on their composition, will more or less attenuate low energetic x-rays and thus the spectrum entering the detector differs from that emitted by the x-ray tube (Duerinckx and Macovski 1978, De Man et al 1999).”
Shape parameter estimation of a 3D model from multi-view radiographic images
Fragnaud, C. (2023) · theses.fr (ABES) · doi:10.70675/c184b73azb203z4d72zb941z4364675c47ce
The Physics of Data Acquisition
Cierniak, R. (2011) · Springer eBooks · doi:10.1007/978-0-85729-027-4_4
- Authors
- Duerinckx, A. J., & Macovski, A.
- Affiliations
- Stanford University (US)
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1978-09
- Volume
- 2
- Issue
- 4
- Pages
- 481-487
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2049442067
- Cited by
- 72
- References
- 0
- Citations by year
- 2025: 1 · 2023: 2 · 2022: 3 · 2021: 1 · 2020: 2 · 2019: 2 · 2018: 1 · 2017: 1 · 2016: 2 · 2015: 2 · 2014: 2 · 2013: 2 · 2012: 3
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Computer Assisted Tomography (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced X-ray and CT Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Keywords
- streak artifacts, polychromatic X-ray beam, dual-energy CT, single-energy CT, artifact removal, petrous bone, test phantom, convolution backprojection
- MeSH terms
- Mathematics, Models, Structural, Tomography, X-Ray Computed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review