Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 248

The DOI matches its Crossref record.

A Single Photon Dynamic Computer Assisted Tomograph (DCAT) for Imaging Brain Function in Multiple Cross Sections

Stokely, Ernest M., Sveinsdottir, Edda, Lassen, Niels A., Rommer, Per · 1980 · Journal of Computer Assisted Tomography

Abstract

A single-photon emission tomograph has been designed and built for regional studies of brain blood flow using 133Xe or 127Xe. The dynamic computer assisted tomograph (DCAT) features fast rotation of a square array of detectors enabling the collection of data in 5 sec, simultaneous recording from three cross-sectional layers, and a field of view the size of the human head. The 64 Nal(Tl) scintillation detectors are arranged in four banks of 16. Each detector consists of a 14 x 2 x 1.3 cm Nal (Tl) crystal fitted with three photomultiplier tubes with one-dimensional positioning capability. Three brain slices (4 cm apart) are examined simultaneously by fitting each crystal with three exchangeable focusing lead collimators. Three collimators have been designed: (a) high resolution dynamic mode collimator for the intracarotid xenon injection method, a complete set of projections gathered over a 180° rotation in a period of 5 sec with 1.7 cm FWHM resolution at the center of image: (b) high sensitivity dynamic mode collimator for performing xenon inhalation studies, a complete set of projections gathered over a 360° rotation in 10 sec with a resolution at the center of the image of 2.5 cm FHWM: and (c) high resolution static mode collimator for 360° rotation and resolution at the image center of 1.1 cm. Angular sampling is either 4 1/2° or 9°. By interlacing offset detectors, linear sampling is reduced to 1/4 or 1/2 the interdetector distance. The calculated high resolution dynamic mode sensitivity of the DCAT is 170.000 counts/sec/μ Ci/ml (three slices) for a 20 cm diameter phantom filled with 99mTc for a resolution of 1.7 cm x 2.3 cm at the image center. The image is reconstructed using either an iterative technique or a filtered back-projection algorithm, with the inclusion of attenuation correction in either case. Early results demonstrate the feasibility of single-photon computed tomography for measuring brain blood flow.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004728-198004000-00022

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 248

Metadata

Authors
Stokely, E. M., Sveinsdottir, E., Lassen, N. A., & Rommer, P.
Venue
Journal of Computer Assisted Tomography
Published
1980-04
Volume
4
Issue
2
Pages
230-240
ISSN
0363-8715 (ISSN-L)
OpenAlex
W1987722078
Cited by
248
References
0
FWCI
10.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Single Photon Dynamic Computer Assisted Tomograph (DCAT) for Imaging Brain Function in Multiple Cross Sections. https://app.cochat.ai/papers/10.1097/00004728-198004000-00022
The paper
Stokely, E. M., Sveinsdottir, E., Lassen, N. A., & Rommer, P. (1980). A Single Photon Dynamic Computer Assisted Tomograph (DCAT) for Imaging Brain Function in Multiple Cross Sections. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198004000-00022

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.