Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 299

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Estimation of cerebral blood flow through color duplex sonography of the carotid and vertebral arteries in healthy adults.

Open access
Schöning, M, Walter, J, Scheel, P·1994·Stroke

Abstract

To noninvasively estimate cerebral blood flow volume, a prospective study of color duplex sonography of the common, external, and internal carotid arteries and vertebral arteries of healthy adults was done. Cerebral blood flow was calculated with the sum of flow volumes in the internal carotid and vertebral arteries of both sides. Using a 7.0-MHz linear transducer of a computed sonography system, cervical arteries of 48 volunteers (23 women, 25 men; mean age, 35 +/- 12 years) were examined. We measured angle-corrected time-averaged velocities and the diameter of the vessels and calculated the flow volumes of all arteries. In addition, peak systolic, maximum end-diastolic, and time-averaged maximum velocities and the resistance, pulsatility, and spectral broadening indexes were determined. Furthermore, we analyzed the side-to-side difference, age dependence, and long-term reproducibility of these parameters. The mean +/- SD values of flow volumes in the common, internal, and external carotid and vertebral arteries were 470 +/- 120, 265 +/- 62, 160 +/- 66, and 85 +/- 33 mL/min on either side, respectively. Total cerebral blood flow was 701 +/- 104 mL/min (corresponding to 54 +/- 8 mL/100 g per minute), with no variation in age or sex. Long-term reproducibility of cerebral blood flow and flow volumes in all vessels was significant (P < .01). We conclude that color duplex sonography of cervical arteries is potentially a practical method for estimating total cerebral blood flow. This noninvasive technique may be ideally suited for bedside and follow-up examinations of the critically ill patient. In future studies it should be compared with established radionuclide techniques.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.str.25.1.17

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 299

Metadata

Authors
Schöning, M., Walter, J., & Scheel, P.
Venue
Stroke
Published
1994-01
Volume
25
Issue
1
Pages
17-22
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2148088686
Cited by
299
References
16
FWCI
2.43
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimation of cerebral blood flow through color duplex sonography of the carotid and vertebral arteries in healthy adults. https://app.cochat.ai/papers/10.1161/01.str.25.1.17
The paper
Schöning, M., Walter, J., & Scheel, P. (1994). Estimation of cerebral blood flow through color duplex sonography of the carotid and vertebral arteries in healthy adults. Stroke. https://doi.org/10.1161/01.str.25.1.17

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.