The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Estimation of cerebral blood flow through color duplex sonography of the carotid and vertebral arteries in healthy adults.
Open accessAbstract
To noninvasively estimate cerebral blood flow volume, a prospective study of color duplex sonography of the common, external, and internal carotid arteries and vertebral arteries of healthy adults was done. Cerebral blood flow was calculated with the sum of flow volumes in the internal carotid and vertebral arteries of both sides. Using a 7.0-MHz linear transducer of a computed sonography system, cervical arteries of 48 volunteers (23 women, 25 men; mean age, 35 +/- 12 years) were examined. We measured angle-corrected time-averaged velocities and the diameter of the vessels and calculated the flow volumes of all arteries. In addition, peak systolic, maximum end-diastolic, and time-averaged maximum velocities and the resistance, pulsatility, and spectral broadening indexes were determined. Furthermore, we analyzed the side-to-side difference, age dependence, and long-term reproducibility of these parameters. The mean +/- SD values of flow volumes in the common, internal, and external carotid and vertebral arteries were 470 +/- 120, 265 +/- 62, 160 +/- 66, and 85 +/- 33 mL/min on either side, respectively. Total cerebral blood flow was 701 +/- 104 mL/min (corresponding to 54 +/- 8 mL/100 g per minute), with no variation in age or sex. Long-term reproducibility of cerebral blood flow and flow volumes in all vessels was significant (P < .01). We conclude that color duplex sonography of cervical arteries is potentially a practical method for estimating total cerebral blood flow. This noninvasive technique may be ideally suited for bedside and follow-up examinations of the critically ill patient. In future studies it should be compared with established radionuclide techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kety, S. S., & Schmidt, C. F. (1948) · Journal of Clinical Investigation · doi:10.1172/jci101994 · Cited by 2,059
CEREBRAL BLOOD FLOW, BLOOD VOLUME AND OXYGEN UTILIZATION: NORMAL VALUES AND EFFECT OF AGE
LEENDERS, K. L., PERANI, D., LAMMERTSMA, A. A., HEATHER, J. D., BUCKINGHAM, P., JONES, T., HEALY, M. J. R., GIBBS, J. M., WISE, R. J. S., HATAZAWA, J., et al. (1990) · Brain · doi:10.1093/brain/113.1.27 · Cited by 1,093
THE DETERMINATION OF CEREBRAL BLOOD FLOW IN MAN BY THE USE OF NITROUS OXIDE IN LOW CONCENTRATIONS
Kety, S. S., & Schmidt, C. F. (1945) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1945.143.1.53 · Cited by 1,053
Measurement of blood flow by ultrasound: Accuracy and sources of error
Gill, R. W. (1985) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(85)90035-3 · Cited by 765
A Positron-Emission Transaxial Tomograph for Nuclear Imaging (PETT)
Ter-Pogossian, M. M., Phelps, M. E., Hoffman, E. J., & Mullani, N. A. (1975) · Radiology · doi:10.1148/114.1.89 · Cited by 680
Human cerebral blood flow and oxygen consumption as related to aging
Kety, S. S. (1956) · Journal of Chronic Diseases · doi:10.1016/0021-9681(56)90146-1 · Cited by 331
Stokely, E. M., Sveinsdottir, E., Lassen, N. A., & Rommer, P. (1980) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198004000-00022 · Cited by 248
Analysis of brain weight. I. Adult brain weight in relation to sex, race, and age.
Kc, H., Roessmann, U., Straumfjord, J. V., & Monroe, G. (1980) · PubMed · Cited by 212
Naritomi, H. (1979) · Archives of Neurology · doi:10.1001/archneur.1979.00500430040005 · Cited by 196
Cerebral blood flow and cerebrovascular CO 2 reactivity in stroke‐age normal controls
Davis, S. M., Ackerman, R. H., Correia, J. A., Alpert, N. M., Chang, J., Buonanno, F., Kelley, R. E., Rosner, B., & Taveras, J. M. (1983) · Neurology · doi:10.1212/wnl.33.4.391 · Cited by 161
Cited by
Sato, K., Ogoh, S., Hirasawa, A., Oue, A., & Sadamoto, T. (2011) · The Journal of Physiology · doi:10.1113/jphysiol.2010.204461 · Cited by 276
Brain and central haemodynamics and oxygenation during maximal exercise in humans
González‐Alonso, J., Dalsgaard, M. K., Osada, T., Volianitis, S., Dawson, E. A., Yoshiga, C. C., & Secher, N. H. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2004.060574 · Cited by 276
Neonatal hemodynamics: Monitoring, data acquisition and analysis
Soleymani, S., Borzage, M., Noori, S., & Seri, I. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.12.32 · Cited by 23
Horiuchi, M., Rossetti, G. M., & Oliver, S. J. (2022) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x20910053 · Cited by 14
Metadata
- Authors
- Schöning, M., Walter, J., & Scheel, P.
- Venue
- Stroke
- Published
- 1994-01
- Volume
- 25
- Issue
- 1
- Pages
- 17-22
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2148088686
- Cited by
- 299
- References
- 16
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimation of cerebral blood flow through color duplex sonography of the carotid and vertebral arteries in healthy adults. https://app.cochat.ai/papers/10.1161/01.str.25.1.17
- The paper
- Schöning, M., Walter, J., & Scheel, P. (1994). Estimation of cerebral blood flow through color duplex sonography of the carotid and vertebral arteries in healthy adults. Stroke. https://doi.org/10.1161/01.str.25.1.17
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.